Skip to main content

Dialink CVE-2022-2969

HIGH
Path Traversal (CWE-22)
2022-12-01 ics-cert@hq.dhs.gov
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
None

Lifecycle Timeline

1
CVE Published
Dec 01, 2022 - 18:15 nvd
HIGH 7.5

DescriptionNVD

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.

AnalysisAI

Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory. Affected products include: Deltaww Dialink.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.

CVE-2021-38424 HIGH
7.8 Nov 03

The tag interface of Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to an attacker injecting formula

CVE-2021-38422 HIGH
7.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior stores sensitive information in cleartext, which may allow an attac

CVE-2021-38420 HIGH
7.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior default permissions give extensive permissions to low-privileged us

CVE-2021-38416 HIGH
7.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior insecurely loads libraries, which may allow an attacker to use DLL

CVE-2022-2660 HIGH
7.5 Dec 13

Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic k

CVE-2021-38418 MEDIUM
5.9 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior runs by default on HTTP, which may allow an attacker to be position

CVE-2021-38488 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38428 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38411 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38407 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2021-38403 MEDIUM
4.8 Nov 03

Delta Electronics DIALink versions 1.2.4.0 and prior is vulnerable to cross-site scripting because an authenticated atta

CVE-2025-58321 CRITICAL
10.0 Sep 11

Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. Rated critical severity (CVSS