Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A remote attacker could overflow a buffer to corrupt adjacent memory by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 2.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Always validate buffer sizes before copy operations. Use bounded functions (strncpy, snprintf). Enable compiler protections.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Buffer Copy without Size Check (CWE-120), which allows attackers to overflow a buffer to corrupt adjacent memory. Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling. Affected products include: Xerox Phaser 6510 Firmware, Xerox Workcentre 6515 Firmware, Xerox Versalink B400 Firmware, Xerox Versalink B405 Firmware, Xerox Versalink B600 Firmware. Version information: before 64.65.51.

Know when Phaser 6510 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling.

Threat Intelligence Overview

EPSS Score
2.2%
Top 20% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 2.2%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

51
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)NVD

cpe:2.3:o:xerox:phaser_6510_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:workcentre_6515_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b400_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b405_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b600_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b610_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b605_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b615_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b7025_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b7030_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_b7035_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c400_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c405_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c500_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c600_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c505_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c605_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c7000_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c7020_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:xerox:versalink_c7025_firmware:*:*:*:*:*:*:*:*
+ 27 more

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy