Skip to main content

Simatic Hmi Comfort Panels Firmware CVE-2020-7592

MEDIUM
Cleartext Transmission of Sensitive Information (CWE-319)
2020-07-14 productcert@siemens.com
6.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
6.5 MEDIUM
AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Jul 14, 2020 - 14:15 nvd
MEDIUM 6.5

DescriptionNVD

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.

AnalysisAI

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-319. A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. Affected products include: Siemens Simatic Hmi Basic Panels 1St Generation, Siemens Simatic Hmi Basic Panels 2Nd Generation, Siemens Simatic Wincc Runtime Advanced, Siemens Simatic Hmi Comfort Panels Firmware, Siemens Simatic Hmi Ktp700F Mobile Arctic Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2020-15798 CRITICAL
9.8 Feb 09

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. Rated critical severity (CVSS 9.8), this vulner

CVE-2020-15786 CRITICAL
9.8 Sep 09

A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. Rated critical severity (CVSS 9.8)

CVE-2019-6572 CRITICAL
9.1 May 14

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI

CVE-2018-13814 HIGH
8.8 Dec 13

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Out

CVE-2018-13813 HIGH
8.1 Dec 13

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Co

CVE-2022-40227 HIGH
7.5 Oct 11

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. Rated high severity (CVSS 7.5), this vulnerabil

CVE-2019-6568 HIGH
7.5 Apr 17

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. Rated hig

CVE-2018-13812 HIGH
7.5 Dec 13

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Co

CVE-2019-6576 MEDIUM
6.5 May 14

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI

CVE-2019-6577 MEDIUM
5.4 May 14

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI

Share

CVE-2020-7592 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy