Patient Information Center Ix
CVE-2020-16228
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V12 - Secure Communication Certificate revocation checking
|
| Impact | CVSS score of 6.4 (MEDIUM). Attack characteristics: adjacent network attack vector, low complexity, high privileges required, no user interaction not required. |
| Exploit ScenarioDerived | Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N. Rated medium severity (CVSS 6.4), this vulnerability is low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-299. In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate. Affected products include: Philips Patient Information Center Ix, Philips Performancebridge Focal Point, Philips Intellivue Mp2-Mp90 Firmware, Philips Intellivue Mx100 Firmware, Philips Intellivue Mx400 Firmware.
Know when Patient Information Center Ix gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control
The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive
Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrect
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but d
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 V
The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from t
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product re
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neut
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB