Skip to main content

Simatic Hmi Comfort Panels Firmware CVE-2020-15786

CRITICAL
Improper Restriction of Excessive Authentication Attempts (CWE-307)
2020-09-09 productcert@siemens.com
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Brute-force prevention, rate limiting
Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. EPSS exploitation probability: 0.42%.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the critical-severity affected system.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.4% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-307. A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack. Affected products include: Siemens Simatic Hmi Basic Panels 2Nd Generation Firmware, Siemens Simatic Hmi Comfort Panels Firmware, Siemens Simatic Hmi Mobile Panels Firmware, Siemens Simatic Hmi United Comfort Panels Firmware.

Know when Simatic Hmi Comfort Panels Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.

Threat Intelligence Overview

EPSS Score
0.4%
Top 38% exploitable
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.4%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

49
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)CVE.org

cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_mobile_panels_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_hmi_united_comfort_panels_firmware:*:*:*:*:*:*:*:*
CVE-2020-15798 CRITICAL
9.8 Feb 09

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. Rated critical severity (CVSS 9.8), this vulner

CVE-2019-6572 CRITICAL
9.1 May 14

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI

CVE-2018-13814 HIGH
8.8 Dec 13

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Out

CVE-2018-13813 HIGH
8.1 Dec 13

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Co

CVE-2022-40227 HIGH
7.5 Oct 11

A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. Rated high severity (CVSS 7.5), this vulnerabil

CVE-2019-6568 HIGH
7.5 Apr 17

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. Rated hig

CVE-2018-13812 HIGH
7.5 Dec 13

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Co

CVE-2019-6576 MEDIUM
6.5 May 14

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI

CVE-2020-7592 MEDIUM
6.5 Jul 14

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. Rated medium severity (CVSS 6.5),

CVE-2019-6577 MEDIUM
5.4 May 14

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy