Sinumerik 840D Sl Firmware
CVE-2020-15783
HIGH
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Lifecycle Timeline
1DescriptionCVE.org
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold restart is required to recover the service.
AnalysisAI
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Uncontrolled Resource Consumption (CWE-400), which allows attackers to cause denial of service by exhausting system resources. A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC TDC CPU555 (All versions), SINUMERIK 840D sl (All versions). Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port 102. A cold restart is required to recover the service. Affected products include: Siemens Sinumerik 840D Sl Firmware, Siemens Simatic S7-300 Cpu 312 Firmware, Siemens Simatic S7-300 Cpu 314 Firmware, Siemens Simatic S7-300 Cpu 315-2 Dp Firmware, Siemens Simatic S7-300 Cpu 315-2 Pn Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement rate limiting, set resource quotas, validate input sizes, use timeouts.
More in Sinumerik 840D Sl Firmware
View allSpecially crafted packets sent to port 161/udp could cause a denial of service condition. Rated high severity (CVSS 8.7)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a loc
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a d
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All ve
Same weakness CWE-400 – Uncontrolled Resource Consumption
View allSame technique Denial Of Service