Skip to main content
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V2 - Validation and Business Logic Resource consumption limits
MITRE ATT&CK

1 technique across 1 tactic: Impact

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 8.7 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. EPSS exploitation probability: 5.26%.

Exploit ScenarioDerived

A remote attacker could cause denial of service by exhausting system resources by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 5.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Specially crafted packets sent to port 161/udp could cause a denial of service condition. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement rate limiting, set resource quotas, validate input sizes, use timeouts.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Uncontrolled Resource Consumption (CWE-400), which allows attackers to cause denial of service by exhausting system resources. Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. Affected products include: Siemens Simatic S7-200 Firmware, Siemens Simatic S7-400Pn V6 Firmware, Siemens Simatic S7-400H V6 Firmware, Siemens Simatic S7-400Pn\/Dp V7 Firmware, Siemens Simatic S7-410 V8 Firmware.

Know when Simatic S7 1500 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.7 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
None
Vulnerable system: Integrity
None
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

Threat Intelligence Overview

EPSS Score
5.3%
Top 10% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 5.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

49
Low Medium High Critical
KEV: 0
EPSS: +5
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

Affected Products (CPE)CVE.org

cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-400pn\/dp_v7_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*
cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*
+ 18 more
CVE-2014-0160 HIGH POC
7.5 Apr 07

The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packe

CVE-2018-3639 MEDIUM POC
5.5 May 22

Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addres

CVE-2020-8744 HIGH
7.8 Nov 12

Improper initialization in subsystem for Intel(R) CSME versions before12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25, I

CVE-2019-6575 HIGH
7.5 Apr 17

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515

CVE-2017-2680 HIGH
7.1 May 11

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a loc

CVE-2019-6568 HIGH
7.5 Apr 17

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. Rated hig

CVE-2018-13815 HIGH
7.5 Dec 13

A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). Rated high

CVE-2018-13805 HIGH
7.5 Oct 10

A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-

CVE-2017-2681 HIGH
7.1 May 11

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a d

CVE-2018-4843 MEDIUM
6.5 Mar 20

A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy