Skip to main content

Scalance M 800 Firmware CVE-2017-2680

HIGH
Uncontrolled Resource Consumption (CWE-400)
2017-05-11 productcert@siemens.com
Denial Of Service Siemens Scalance M 800 Firmware Scalance S615 Firmware Scalance Xm400 Firmware Scalance Xr500 Firmware Simatic S7 1500 Firmware Simatic Cp 1543 1 Firmware Simatic S7 1200 Firmware Simatic Cp 343 1 Std Firmware Simatic Cp 343 1 Lean Firmware Simatic Cp 343 1 Adv Firmware Simatic Cp 443 1 Std Firmware Simatic Cp 443 1 Adv Firmware Simatic Cp 443 1 Opc Ua Firmware Simatic Cp 1243 1 Firmware Simatic Cm 1542 1 Firmware Simatic Cp 1542Sp 1 Firmware Simatic Cp 1542Sp 1 Irc Firmware Simatic Cp 1543Sp 1 Firmware Simatic Rf650R Firmware Simatic Rf680R Firmware Simatic Rf685R Firmware Simatic Cp 1616 Firmware Simatic Cp 1604 Firmware Simatic Dk 1616 Pn Io Firmware Scalance X200 Firmware Scalance X200 Irt Firmware Scalance X300 Firmware Scalance X408 Firmware Scalance X414 Firmware Scalance W700 Firmware Softnet Profinet Io Firmware Ie Pb Link Firmware Ie As I Link Pn Io Firmware Simatic Teleservice Adapter Ie Standard Firmware Simatic Teleservice Adapter Ie Basic Firmware Simatic Teleservice Adapter Ie Advanced Firmware Sitop Psu8600 Firmware Ups1600 Profinet Firmware Simatic Et 200Al Firmware Simatic Et 200Ecopn Firmware Simatic Et 200M Firmware Simatic Et 200Mp Firmware Simatic Et 200Pro Firmware Simatic Et 200S Firmware Simatic Et 200Sp Firmware Pn Pn Coupler Firmware Dk Standard Ethernet Controller Firmware Ek Ertec 200P Pn Io Firmware Ek Ertec 200 Pn Io Firmware Simatic S7 200 Smart Firmware Simatic S7 300 Firmware Simatic S7 400 Firmware Simatic S7 1500 Software Controller Firmware Simatic Winac Rtx Firmware Sirius Act 3Su1 Firmware Sirius Soft Starter 3Rw44 Pn Firmware Sirius Motor Starter M200D Profinet Firmware Simocode Pro V Profinet Firmware Sinamics Dcm Firmware Sinamics Dcp Firmware Sinamics G110M Firmware Sinamics G120 C P D W Pn Firmware Sinamics G130 Firmware Sinamics G150 Firmware Sinamics S110 Pn Firmware Sinamics S120 Firmware Sinamics S150 Firmware Sinamics V90 Pn Firmware Simotion Firmware Sinumerik 828D Firmware Sinumerik 840D Sl Firmware Simatic Hmi Comfort Panels Simatic Hmi Multi Panels Simatic Hmi Mobile Panels Simatic Cp 1243 1 Irc Firmware Simatic Cp 1243 1 Iec Firmware Simatic Cp 1243 1 Dnp3 Firmware Simatic Dk 1604 Pn Io Firmware Simatic Tdc Cpu555 Firmware Simatic Tdc Cp51M1 Firmware Sinamics Gh150 Firmware Sinamics Gl150 Firmware Sinamics Gm150 Firmware Sinamics Sl150 Firmware Sinamics Sm120 Firmware Extension Unit 12 Profinet Firmware Extension Unit 15 Profinet Firmware Extension Unit 19 Profinet Firmware Extension Unit 22 Profinet Firmware Simatic Cp 1242 7 Gprs Firmware Simatic Cp 1243 7 Lte Us Firmware Simatic Cp 1243 8 Firmware Simatic Cp 1626 Firmware
7.1
CVSS 4.0 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V2 - Validation and Business Logic Resource consumption limits
MITRE ATT&CK

1 technique across 1 tactic: Impact

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.1 (HIGH). Attack characteristics: adjacent network attack vector, low complexity, no privileges required, no user interaction not required. EPSS exploitation probability: 2.33%.

Exploit ScenarioDerived

An attacker could exploit this vulnerability to cause denial of service by exhausting system resources. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 2.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Rated high severity (CVSS 7.1), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement rate limiting, set resource quotas, validate input sizes, use timeouts.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Uncontrolled Resource Consumption (CWE-400), which allows attackers to cause denial of service by exhausting system resources. Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. Affected products include: Siemens Simatic Cp 343-1 Std Firmware, Siemens Simatic Cp 343-1 Lean Firmware, Siemens Simatic Cp 343-1 Adv Firmware, Siemens Simatic Cp 443-1 Std Firmware, Siemens Simatic Cp 443-1 Adv Firmware.

Know when Scalance M 800 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.1 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
None
Vulnerable system: Integrity
None
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

Threat Intelligence Overview

EPSS Score
2.3%
Top 15% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 2.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

38
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

Affected Products (CPE)CVE.org

cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*
+ 96 more
CVE-2017-14491 CRITICAL POC
9.8 Oct 04

Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execut

CVE-2021-3449 MEDIUM
5.9 Mar 25

An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. Rated med

CVE-2022-36323 CRITICAL
9.1 Aug 10

Affected devices do not properly sanitize an input field. Rated critical severity (CVSS 9.1), this vulnerability is remo

CVE-2022-36324 HIGH
7.5 Aug 10

Affected devices do not properly handle the renegotiation of SSL/TLS parameters. Rated high severity (CVSS 7.5), this vu

CVE-2021-25667 HIGH
8.8 Mar 15

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions

CVE-2022-36325 MEDIUM
6.8 Aug 10

Affected devices do not properly sanitize data introduced by an user when rendering the web interface. Rated medium seve

CVE-2021-25676 HIGH
7.5 Mar 15

A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC

CVE-2018-5391 HIGH
7.5 Sep 06

The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packet

CVE-2017-2681 HIGH
7.1 May 11

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a d

CVE-2016-7090 MEDIUM
4.0 Sep 29

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure f

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy