1DescriptionNVD
Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system.
AnalysisAI
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-330. Prima Systems FlexAir, Versions 2.3.38 and prior. The application generates database backup files with a predictable name, and an attacker can use brute force to identify the database backup file name. A malicious actor can exploit this issue to download the database file and disclose login information, which can allow the attacker to bypass authentication and have full access to the system. Affected products include: Primasystems Flexair.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated critical severity (CVSS 9.0), this vulnerability is remotely exp
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 7.2), this vulnerability is remotely exploit
Prima Systems FlexAir devices have Default Credentials. Rated critical severity (CVSS 9.8), this vulnerability is remote
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.4.9api3 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely expl
Same weakness CWE-330 – Use of Insufficiently Random Values
View allSame technique Information Disclosure