Flexair
CVE-2019-7670
HIGH
Severity by source
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.
AnalysisAI
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system. Affected products include: Primasystems Flexair.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated critical severity (CVSS 9.8), this vulnerability is remotely exp
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated critical severity (CVSS 9.0), this vulnerability is remotely exp
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir devices have Default Credentials. Rated critical severity (CVSS 9.8), this vulnerability is remote
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.3.38 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely exploit
Prima Systems FlexAir, Versions 2.4.9api3 and prior. Rated high severity (CVSS 8.8), this vulnerability is remotely expl
Same weakness CWE-78 – OS Command Injection
View allSame technique Command Injection
View allShare
External POC / Exploit Code
Leaving vuln.today