Skip to main content

Amazon CVE-2019-13120

HIGH
Out-of-bounds Read (CWE-125)
2019-10-07 cve@mitre.org
7.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, read limits
MITRE ATT&CK

1 technique across 1 tactic: Collection

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

A remote attacker could read data from memory outside the intended buffer boundaries by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 1.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Amazon FreeRTOS up to and including v1.4.8 lacks length checking in prvProcessReceivedPublish, resulting in untargetable leakage of arbitrary memory contents on a device to an attacker. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. Amazon FreeRTOS up to and including v1.4.8 lacks length checking in prvProcessReceivedPublish, resulting in untargetable leakage of arbitrary memory contents on a device to an attacker. If an attacker has the authorization to send a malformed MQTT publish packet to an Amazon IoT Thing, which interacts with an associated vulnerable MQTT message in the application, specific circumstances could trigger this vulnerability. Affected products include: Amazon Amazon Web Services Freertos.

Know when Amazon gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

DescriptionNVD

Amazon FreeRTOS up to and including v1.4.8 lacks length checking in prvProcessReceivedPublish, resulting in untargetable leakage of arbitrary memory contents on a device to an attacker. If an attacker has the authorization to send a malformed MQTT publish packet to an Amazon IoT Thing, which interacts with an associated vulnerable MQTT message in the application, specific circumstances could trigger this vulnerability.

Threat Intelligence Overview

EPSS Score
1.2%
Top 36% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 1.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

39
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +38
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)NVD

cpe:2.3:a:amazon:amazon_web_services_freertos:*:*:*:*:*:*:*:*

More in Amazon

View all
CVE-2023-44487 HIGH POC
7.5 Oct 10

Denial of service against HTTP/2 server implementations allows remote unauthenticated attackers to exhaust server resour

CVE-2024-6387 HIGH POC
8.1 Jul 01

Remote code execution in OpenSSH's sshd server (regression of CVE-2006-5051) allows unauthenticated remote attackers to

CVE-2024-28056 CRITICAL POC
9.8 Apr 15

Amazon AWS Amplify CLI before 12.10.1 incorrectly configures the role trust policy of IAM roles associated with Amplify

CVE-2022-25809 CRITICAL POC
9.8 Feb 24

Improper Neutralization of audio output from 3rd and 4th Generation Amazon Echo Dot devices allows arbitrary voice comma

CVE-2021-44833 CRITICAL POC
9.8 Dec 12

The CLI 1.0.0 for Amazon AWS OpenSearch has weak permissions for the configuration file. Rated critical severity (CVSS 9

CVE-2019-3984 CRITICAL POC
9.8 Dec 31

Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary commands on the device due

CVE-2019-3989 CRITICAL POC
9.8 Dec 11

Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary commands on the device due

CVE-2023-35165 HIGH POC
8.8 Jun 23

AWS Cloud Development Kit (AWS CDK) is an open-source software development framework to define cloud infrastructure in c

CVE-2022-31115 HIGH POC
8.8 Jun 30

opensearch-ruby is a community-driven, open source fork of elasticsearch-ruby. Rated high severity (CVSS 8.8), this vuln

CVE-2022-0070 HIGH POC
8.8 Apr 19

Incomplete fix for CVE-2021-3100. Rated high severity (CVSS 8.8), this vulnerability is low attack complexity. Public ex

CVE-2021-43638 HIGH POC
8.8 Dec 07

Amazon Amazon WorkSpaces agent is affected by Integer Overflow. Rated high severity (CVSS 8.8), this vulnerability is lo

CVE-2021-43637 HIGH POC
8.8 Dec 07

Amazon WorkSpaces agent is affected by Buffer Overflow. Rated high severity (CVSS 8.8), this vulnerability is low attack

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy