Scalance X 408 Firmware
CVE-2014-8479
MEDIUM
Severity by source
AV:N/AC:L/Au:S/C:N/I:N/A:C
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
AV:N/AC:L/Au:S/C:N/I:N/A:C
Lifecycle Timeline
1DescriptionCVE.org
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.
AnalysisAI
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot). Rated medium severity (CVSS 6.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-20. The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets. Affected products include: Siemens Scalance X-408 Firmware, Siemens Scalance X-300 Series Firmware. Version information: before 4.0.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.