Intelligent Platforms Proficy Hmi Scada Ifix
CVE-2013-2823
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V2 - Validation and Business Logic Input validation, allowlisting
|
| Impact | CVSS score of 4.7 (MEDIUM). Attack characteristics: local attack vector, M complexity. EPSS exploitation probability: 0.12%. |
| Exploit ScenarioDerived | Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent. Rated medium severity (CVSS 4.7). No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-20. The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. Affected products include: Catapultsoftware Catapult Dnp3 I\/O Driver, Ge Intelligent Platforms Proficy Dnp3 I\/O Driver, Ge Intelligent Platforms Proficy Hmi\/Scada Cimplicity, Ge Intelligent Platforms Proficy Hmi\/Scada Ifix. Version information: before 7.2.0.60.
Severity by source
AV:L/AC:M/Au:N/C:N/I:N/A:C
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.
Affected Products (CPE)CVE.org
An ActiveX control in KeyHelp.ocx in KeyWorks KeyHelp Module (aka the HTML Help component), as used in GE Intelligent Pl
Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHel
The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.2
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB