CVE-2026-2460 Feb 24, 14:16 HIGH This Week

Improper access control in REB500 firmware allows authenticated users with low privileges to read and modify unauthorized directories via the DAC protocol. An attacker with valid credentials can escalate their file system access beyond their intended permissions, potentially compromising sensitive data or system integrity. No patch is currently available for this vulnerability.

Information Disclosure Reb500 Firmware Hitachienergy
NVD
CVSS 3.1
8.1
EPSS
0.0%
CVE-2026-2459 Feb 24, 14:16 HIGH This Week

Authenticated users with Installer role in REB500 firmware can bypass directory access controls to read and modify files outside their authorized scope. This privilege escalation affects systems where installer accounts are provisioned, enabling unauthorized data access and manipulation. No patch is currently available.

Information Disclosure Reb500 Firmware Hitachienergy
NVD
CVSS 4.0
7.4
EPSS
0.0%
CVE-2026-1773 Feb 24, 14:16 HIGH This Week

IEC 60870-5-104: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. [CVSS 7.5 HIGH]

Denial Of Service Rtu520 Firmware Rtu530 Firmware Rtu540 Firmware Rtu560 Firmware +1
NVD VulDB
CVSS 4.0
8.7
EPSS
0.1%
CVE-2026-1772 Feb 24, 14:16 MEDIUM This Month

Improper access controls in RTU500 series firmware (RTU520, RTU530, RTU540, RTU560) expose sensitive user management data to unauthenticated attackers who leverage browser developer tools to bypass web interface restrictions. An attacker without privileges can read confidential user information that should require authentication, though the vulnerability requires direct access to development utilities rather than simple network requests. No patch is currently available for this medium-severity exposure.

Information Disclosure Rtu520 Firmware Rtu530 Firmware Rtu540 Firmware Rtu560 Firmware +1
NVD
CVSS 3.1
5.3
EPSS
0.0%
CVE-2025-39205 Jun 24, 13:15 MEDIUM This Month

A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
6.5
EPSS
0.0%
CVE-2025-39204 Jun 24, 12:15 MEDIUM This Month

A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
6.5
EPSS
0.1%
CVE-2025-39203 Jun 24, 12:15 MEDIUM This Month

A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.

Denial Of Service Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
6.5
EPSS
0.1%
CVE-2025-39202 Jun 24, 12:15 HIGH This Week

CVE-2025-39202 is a local privilege escalation vulnerability in MicroSCADA X SYS600's Monitor Pro interface that allows authenticated users with low privileges to read and overwrite arbitrary files, leading to information disclosure and data corruption. The vulnerability affects the SYS600 product line and requires local access with valid credentials; while the CVSS score of 7.3 indicates moderate-to-high severity, real-world exploitability depends on whether this vulnerability has been added to CISA's KEV catalog or has publicly available proof-of-concept code.

Information Disclosure Path Traversal SCADA Siemens Microscada X Sys600 +1
NVD
CVSS 3.1
7.3
EPSS
0.0%
CVE-2025-39201 Jun 24, 12:15 MEDIUM This Month

A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.

Privilege Escalation Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
6.1
EPSS
0.1%
CVE-2024-41156 Oct 29, 13:15 LOW Monitor

Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Rated low severity (CVSS 2.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Tro610 Firmware Tro620 Firmware Tro670 Firmware Hitachienergy
NVD
CVSS 3.1
2.7
EPSS
0.4%
CVE-2024-41153 Oct 29, 13:15 HIGH This Week

Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Tro610 Firmware Tro620 Firmware Tro670 Firmware Hitachienergy
NVD
CVSS 3.1
7.2
EPSS
1.6%
CVE-2024-7941 Aug 27, 13:15 MEDIUM This Month

An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Open Redirect Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
4.3
EPSS
0.3%
CVE-2024-7940 Aug 27, 13:15 CRITICAL Act Now

The product exposes a service that is intended for local only to all network interfaces without any authentication. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
9.8
EPSS
0.5%
CVE-2024-4872 Aug 27, 13:15 HIGH This Week

A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Code Injection Nosql Injection Microscada X Sys600 Microscada Pro Sys600 Hitachienergy
NVD
CVSS 3.1
8.8
EPSS
0.5%
CVE-2024-3982 Aug 27, 13:15 HIGH This Week

An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already. Rated high severity (CVSS 8.2), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
8.2
EPSS
0.2%
CVE-2024-3980 Aug 27, 13:15 HIGH This Week

The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Path Traversal Microscada X Sys600 Microscada Pro Sys600 Hitachienergy
NVD
CVSS 3.1
8.8
EPSS
0.6%
CVE-2024-28024 Jun 11, 19:16 MEDIUM This Month

A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is stored in cleartext within a resource that might be accessible to another control sphere. Rated medium severity (CVSS 4.1). No vendor patch available.

Information Disclosure Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
4.1
EPSS
0.1%
CVE-2024-28022 Jun 11, 19:16 MEDIUM This Month

A vulnerability exists in the UNEM server / APIGateway that if exploited allows a malicious user to perform an arbitrary number of authentication attempts using different passwords, and eventually. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
6.5
EPSS
0.4%
CVE-2024-28020 Jun 11, 19:16 HIGH This Week

A user/password reuse vulnerability exists in the FOXMAN-UN/UNEM application and server management. Rated high severity (CVSS 8.0), this vulnerability is remotely exploitable. No vendor patch available.

Information Disclosure Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
8.0
EPSS
0.4%
CVE-2024-2013 Jun 11, 14:15 CRITICAL Act Now

An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers without any access to interact with the services and the. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
10.0
EPSS
0.7%
CVE-2024-2012 Jun 11, 14:15 CRITICAL Act Now

vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or code to be executed on the UNEM server allowing sensitive data. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
9.8
EPSS
0.6%
CVE-2024-2011 Jun 11, 14:15 CRITICAL Act Now

A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can be used to execute arbitrary code, which is usually. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Buffer Overflow Denial Of Service Heap Overflow Foxman Un +2
NVD
CVSS 3.1
9.8
EPSS
0.5%
CVE-2024-28021 Jun 11, 14:15 HIGH This Week

A vulnerability exists in the FOXMAN-UN/UNEM server that affects the message queueing mechanism’s certificate validation. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
7.4
EPSS
0.3%
CVE-2022-3864 Jan 04, 10:15 MEDIUM This Month

A vulnerability exists in the Relion update package signature validation. Rated medium severity (CVSS 4.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Jwt Attack Relion 650 Firmware Relion 670 Firmware Relion Sam600 Io Firmware +1
NVD
CVSS 3.1
4.5
EPSS
0.0%
CVE-2022-2081 Jan 04, 10:15 HIGH This Week

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Memory Corruption Rtu520 Firmware Rtu530 Firmware Rtu540 Firmware +2
NVD
CVSS 3.1
7.5
EPSS
0.2%
CVE-2023-6711 Dec 19, 15:15 HIGH This Week

Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Rtu500 Firmware Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.7%
CVE-2023-1514 Dec 19, 15:15 HIGH This Week

A vulnerability exists in the component RTU500 Scripting interface. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Rtu500 Scripting Interface Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.3%
CVE-2023-5769 Dec 14, 17:15 MEDIUM This Month

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Rtu520 Firmware Rtu530 Firmware Rtu540 Firmware Rtu560 Firmware +1
NVD
CVSS 3.1
6.1
EPSS
0.4%
CVE-2023-5768 Dec 04, 15:15 MEDIUM This Month

A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Rtu520 Firmware Rtu530 Firmware Rtu540 Firmware Rtu560 Firmware +1
NVD
CVSS 3.1
6.1
EPSS
0.4%
CVE-2023-5767 Dec 04, 15:15 MEDIUM This Month

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Rtu520 Firmware Rtu530 Firmware Rtu540 Firmware Rtu560 Firmware +1
NVD
CVSS 3.1
6.1
EPSS
0.4%
CVE-2023-4518 Dec 01, 15:15 HIGH This Week

A vulnerability exists in the input validation of the GOOSE messages where out of range values received and processed by the IED caused a reboot of the device. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Relion 650 Firmware Relion 670 Firmware Relion Sam600 Io Firmware Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.7%
CVE-2023-5516 Nov 01, 03:15 MEDIUM This Month

Poorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlying technology and other sensitive. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Esoms Hitachienergy
NVD
CVSS 3.1
5.3
EPSS
0.4%
CVE-2023-5515 Nov 01, 03:15 MEDIUM This Month

The responses for web queries with certain parameters disclose internal path of resources. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Esoms Hitachienergy
NVD
CVSS 3.1
5.3
EPSS
0.4%
CVE-2023-5514 Nov 01, 03:15 MEDIUM This Month

The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Esoms Hitachienergy
NVD
CVSS 3.1
5.3
EPSS
0.4%
CVE-2023-2622 Nov 01, 03:15 MEDIUM This Month

Authenticated clients can read arbitrary files on the MAIN Computer system using the remote procedure call (RPC) of the InspectSetup service endpoint. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Modular Advanced Control For Hvdc Hitachienergy
NVD
CVSS 3.1
4.3
EPSS
0.4%
CVE-2023-2621 Nov 01, 03:15 MEDIUM This Month

The McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Path Traversal Modular Advanced Control For Hvdc Hitachienergy
NVD
CVSS 3.1
6.5
EPSS
0.5%
CVE-2023-4816 Sep 11, 08:15 HIGH This Week

A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Asset Suite Hitachienergy
NVD
CVSS 3.1
8.8
EPSS
0.5%
CVE-2023-1711 May 30, 19:15 MEDIUM This Month

A vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authentication to the network elements. Rated medium severity (CVSS 4.4), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Foxman Un Unem Hitachienergy
NVD
CVSS 3.1
4.4
EPSS
0.2%
CVE-2022-2513 Nov 22, 11:15 MEDIUM This Month

A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below,. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Pcm600 650Connectivitypackage 670Connectivitypackage Gms600Connectivitypackage +3
NVD
CVSS 3.1
5.5
EPSS
0.1%
CVE-2022-3388 Nov 21, 19:15 HIGH This Week

An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

RCE Microscada X Sys600 Microscada Pro Sys600 Hitachienergy
NVD
CVSS 3.1
7.8
EPSS
0.3%
CVE-2022-2277 Sep 14, 18:15 HIGH This Week

Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.7%
CVE-2022-29922 Sep 14, 18:15 HIGH This Week

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.7%
CVE-2022-29492 Sep 14, 18:15 HIGH This Week

Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.6%
CVE-2022-1778 Sep 14, 18:15 MEDIUM This Month

Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. Rated medium severity (CVSS 4.4), this vulnerability is low attack complexity. No vendor patch available.

Buffer Overflow Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
4.4
EPSS
0.4%
CVE-2022-29490 Sep 12, 21:15 HIGH This Week

Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Microscada X Sys600 Hitachienergy
NVD
CVSS 3.1
8.8
EPSS
0.6%
CVE-2022-28613 May 02, 19:15 HIGH This Week

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Rtu500 Firmware Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.9%
CVE-2021-40334 Dec 02, 19:15 HIGH This Week

Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Fox615 Firmware Xcm20 Firmware Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
1.0%
CVE-2021-40333 Dec 02, 19:15 HIGH This Week

Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Brute Force Fox615 Firmware Xcm20 Firmware Hitachienergy
NVD
CVSS 3.1
7.1
EPSS
0.6%
CVE-2021-35533 Nov 26, 17:15 HIGH This Week

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Rtu500 Firmware Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.9%
CVE-2021-35534 Nov 18, 17:15 HIGH This Week

Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Relion 650 Firmware Relion 670 Firmware Relion Sam600 Io Firmware Gms600 Firmware +2
NVD
CVSS 3.1
7.2
EPSS
1.7%
CVE-2021-35535 Nov 18, 16:15 HIGH This Week

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Relion 650 Firmware Relion 670 Firmware Relion Sam600 Io Firmware Hitachienergy
NVD
CVSS 3.1
8.1
EPSS
0.6%
CVE-2021-35528 Nov 17, 18:15 HIGH This Week

Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute. Rated high severity (CVSS 7.1), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Java Retail Operations Counterparty Settlements And Billing Hitachienergy
NVD
CVSS 3.1
7.1
EPSS
0.3%
CVE-2021-35529 Aug 20, 18:15 HIGH This Week

Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Abb Counterparty Settlement And Billing Retail Operations Hitachienergy
NVD
CVSS 3.1
7.2
EPSS
1.3%
CVE-2021-35527 Jul 14, 14:15 HIGH This Week

Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Esoms Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
1.0%
CVE-2021-27196 Jun 14, 22:15 HIGH This Week

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600,. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Reb500 Firmware Relion 650 Firmware Relion 670 Firmware +7
NVD
CVSS 3.1
7.5
EPSS
1.6%
CVE-2021-26845 Jun 14, 22:15 HIGH This Week

Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Information Disclosure Abb Esoms Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
0.9%
CVE-2019-18253 Nov 27, 23:15 CRITICAL Act Now

An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Path Traversal Relion 670 Firmware Hitachienergy
NVD
CVSS 3.1
10.0
EPSS
2.0%
CVE-2019-18247 Nov 27, 23:15 HIGH This Week

An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Relion 650 Firmware Relion 670 Firmware Hitachienergy
NVD
CVSS 3.1
7.5
EPSS
1.6%
CVE-2018-14805 Aug 29, 16:29 CRITICAL Act Now

ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Abb Esoms Hitachienergy
NVD
CVSS 3.0
9.8
EPSS
4.8%
CVE-2018-1168 Feb 21, 14:29 HIGH This Week

This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Abb Sys600 Firmware Hitachienergy
NVD
CVSS 3.0
7.8
EPSS
0.3%
CVE-2017-16731 Dec 20, 19:29 HIGH This Week

An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (including Ellipse Select). Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Ellipse Hitachienergy
NVD
CVSS 3.0
8.8
EPSS
0.1%
CVE-2017-14025 Nov 06, 22:29 MEDIUM This Month

An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Abb Fox515T Firmware Hitachienergy
NVD
CVSS 3.0
5.5
EPSS
0.2%
CVE-2017-15583 Oct 18, 08:29 MEDIUM This Month

The embedded web server on ABB Fox515T 1.0 devices is vulnerable to Local File Inclusion. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Abb Fox515T Firmware Hitachienergy
NVD
CVSS 3.0
6.5
EPSS
0.4%
EPSS 0% CVSS 8.1
HIGH This Week

Improper access control in REB500 firmware allows authenticated users with low privileges to read and modify unauthorized directories via the DAC protocol. An attacker with valid credentials can escalate their file system access beyond their intended permissions, potentially compromising sensitive data or system integrity. No patch is currently available for this vulnerability.

Information Disclosure Reb500 Firmware Hitachienergy
NVD
EPSS 0% CVSS 7.4
HIGH This Week

Authenticated users with Installer role in REB500 firmware can bypass directory access controls to read and modify files outside their authorized scope. This privilege escalation affects systems where installer accounts are provisioned, enabling unauthorized data access and manipulation. No patch is currently available.

Information Disclosure Reb500 Firmware Hitachienergy
NVD
EPSS 0% CVSS 8.7
HIGH This Week

IEC 60870-5-104: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. [CVSS 7.5 HIGH]

Denial Of Service Rtu520 Firmware Rtu530 Firmware +3
NVD VulDB
EPSS 0% CVSS 5.3
MEDIUM This Month

Improper access controls in RTU500 series firmware (RTU520, RTU530, RTU540, RTU560) expose sensitive user management data to unauthenticated attackers who leverage browser developer tools to bypass web interface restrictions. An attacker without privileges can read confidential user information that should require authentication, though the vulnerability requires direct access to development utilities rather than simple network requests. No patch is currently available for this medium-severity exposure.

Information Disclosure Rtu520 Firmware Rtu530 Firmware +3
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface can be malformed, so returning data can leak unauthorized information to the user.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop.

Denial Of Service Microscada X Sys600 Hitachienergy
NVD
EPSS 0% CVSS 7.3
HIGH This Week

CVE-2025-39202 is a local privilege escalation vulnerability in MicroSCADA X SYS600's Monitor Pro interface that allows authenticated users with low privileges to read and overwrite arbitrary files, leading to information disclosure and data corruption. The vulnerability affects the SYS600 product line and requires local access with valid credentials; while the CVSS score of 7.3 indicates moderate-to-high severity, real-world exploitability depends on whether this vulnerability has been added to CISA's KEV catalog or has publicly available proof-of-concept code.

Information Disclosure Path Traversal SCADA +3
NVD
EPSS 0% CVSS 6.1
MEDIUM This Month

A vulnerability exists in MicroSCADA X SYS600 product. If exploited this could allow a local unauthenticated attacker to tamper a system file, making denial of Notify service.

Privilege Escalation Microscada X Sys600 Hitachienergy
NVD
EPSS 0% CVSS 2.7
LOW Monitor

Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. Rated low severity (CVSS 2.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Tro610 Firmware Tro620 Firmware +2
NVD
EPSS 2% CVSS 7.2
HIGH This Week

Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Tro610 Firmware Tro620 Firmware +2
NVD
EPSS 0% CVSS 4.3
MEDIUM This Month

An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Open Redirect Microscada X Sys600 Hitachienergy
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

The product exposes a service that is intended for local only to all network interfaces without any authentication. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Microscada X Sys600 Hitachienergy
NVD
EPSS 0% CVSS 8.8
HIGH This Week

A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Code Injection Nosql Injection Microscada X Sys600 +2
NVD
EPSS 0% CVSS 8.2
HIGH This Week

An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already. Rated high severity (CVSS 8.2), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
EPSS 1% CVSS 8.8
HIGH This Week

The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Path Traversal Microscada X Sys600 Microscada Pro Sys600 +1
NVD
EPSS 0% CVSS 4.1
MEDIUM This Month

A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is stored in cleartext within a resource that might be accessible to another control sphere. Rated medium severity (CVSS 4.1). No vendor patch available.

Information Disclosure Foxman Un Unem +1
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

A vulnerability exists in the UNEM server / APIGateway that if exploited allows a malicious user to perform an arbitrary number of authentication attempts using different passwords, and eventually. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Foxman Un Unem +1
NVD
EPSS 0% CVSS 8.0
HIGH This Week

A user/password reuse vulnerability exists in the FOXMAN-UN/UNEM application and server management. Rated high severity (CVSS 8.0), this vulnerability is remotely exploitable. No vendor patch available.

Information Disclosure Foxman Un Unem +1
NVD
EPSS 1% CVSS 10.0
CRITICAL Act Now

An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers without any access to interact with the services and the. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Foxman Un Unem +1
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or code to be executed on the UNEM server allowing sensitive data. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Foxman Un Unem +1
NVD
EPSS 0% CVSS 9.8
CRITICAL Act Now

A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can be used to execute arbitrary code, which is usually. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Buffer Overflow Denial Of Service +4
NVD
EPSS 0% CVSS 7.4
HIGH This Week

A vulnerability exists in the FOXMAN-UN/UNEM server that affects the message queueing mechanism’s certificate validation. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Foxman Un Unem +1
NVD
EPSS 0% CVSS 4.5
MEDIUM This Month

A vulnerability exists in the Relion update package signature validation. Rated medium severity (CVSS 4.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Denial Of Service Jwt Attack Relion 650 Firmware +3
NVD
EPSS 0% CVSS 7.5
HIGH This Week

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Memory Corruption Rtu520 Firmware +4
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Rtu500 Firmware Hitachienergy
NVD
EPSS 0% CVSS 7.5
HIGH This Week

A vulnerability exists in the component RTU500 Scripting interface. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Rtu500 Scripting Interface Hitachienergy
NVD
EPSS 0% CVSS 6.1
MEDIUM This Month

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Rtu520 Firmware Rtu530 Firmware +3
NVD
EPSS 0% CVSS 6.1
MEDIUM This Month

A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Rtu520 Firmware Rtu530 Firmware +3
NVD
EPSS 0% CVSS 6.1
MEDIUM This Month

A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

XSS Rtu520 Firmware Rtu530 Firmware +3
NVD
EPSS 1% CVSS 7.5
HIGH This Week

A vulnerability exists in the input validation of the GOOSE messages where out of range values received and processed by the IED caused a reboot of the device. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Relion 650 Firmware Relion 670 Firmware +2
NVD
EPSS 0% CVSS 5.3
MEDIUM This Month

Poorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlying technology and other sensitive. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Esoms Hitachienergy
NVD
EPSS 0% CVSS 5.3
MEDIUM This Month

The responses for web queries with certain parameters disclose internal path of resources. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Esoms Hitachienergy
NVD
EPSS 0% CVSS 5.3
MEDIUM This Month

The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local file system structure. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Esoms Hitachienergy
NVD
EPSS 0% CVSS 4.3
MEDIUM This Month

Authenticated clients can read arbitrary files on the MAIN Computer system using the remote procedure call (RPC) of the InspectSetup service endpoint. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Modular Advanced Control For Hvdc Hitachienergy
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

The McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Path Traversal Modular Advanced Control For Hvdc Hitachienergy
NVD
EPSS 1% CVSS 8.8
HIGH This Week

A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Asset Suite Hitachienergy
NVD
EPSS 0% CVSS 4.4
MEDIUM This Month

A vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authentication to the network elements. Rated medium severity (CVSS 4.4), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Foxman Un Unem +1
NVD
EPSS 0% CVSS 5.5
MEDIUM This Month

A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below,. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Pcm600 650Connectivitypackage +5
NVD
EPSS 0% CVSS 7.8
HIGH This Week

An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

RCE Microscada X Sys600 Microscada Pro Sys600 +1
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Microscada X Sys600 Hitachienergy
NVD
EPSS 0% CVSS 4.4
MEDIUM This Month

Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. Rated medium severity (CVSS 4.4), this vulnerability is low attack complexity. No vendor patch available.

Buffer Overflow Microscada X Sys600 Hitachienergy
NVD
EPSS 1% CVSS 8.8
HIGH This Week

Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Microscada X Sys600 Hitachienergy
NVD
EPSS 1% CVSS 7.5
HIGH This Week

A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Rtu500 Firmware +1
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulnerability by activating SSH on port TCP. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Fox615 Firmware Xcm20 Firmware +1
NVD
EPSS 1% CVSS 7.1
HIGH This Week

Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN) routing configuration. Rated high severity (CVSS 7.1), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Brute Force Fox615 Firmware +2
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Rtu500 Firmware Hitachienergy
NVD
EPSS 2% CVSS 7.2
HIGH This Week

Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows attacker who successfully exploited. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Relion 650 Firmware Relion 670 Firmware +4
NVD
EPSS 1% CVSS 8.1
HIGH This Week

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of. Rated high severity (CVSS 8.1), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Information Disclosure Relion 650 Firmware Relion 670 Firmware +2
NVD
EPSS 0% CVSS 7.1
HIGH This Week

Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Billing (CSB) allows an attacker to execute. Rated high severity (CVSS 7.1), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Java Retail Operations +2
NVD
EPSS 1% CVSS 7.2
HIGH This Week

Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB) allows an attacker or unauthorized user. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Authentication Bypass Abb Counterparty Settlement And Billing +2
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials that are stored by the browser. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Esoms +1
NVD
EPSS 2% CVSS 7.5
HIGH This Week

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600,. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Reb500 Firmware +9
NVD
EPSS 1% CVSS 7.5
HIGH This Week

Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report is discovered. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Information Disclosure Abb +2
NVD
EPSS 2% CVSS 10.0
CRITICAL Act Now

An attacker could use specially crafted paths in a specific request to read or delete files from Relion 670 Series (versions 1p1r26, 1.2.3.17, 2.0.0.10, RES670 2.0.0.4, 2.1.0.1, and prior) outside. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Path Traversal Relion 670 Firmware Hitachienergy
NVD
EPSS 2% CVSS 7.5
HIGH This Week

An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Relion 650 Firmware Relion 670 Firmware +1
NVD
EPSS 5% CVSS 9.8
CRITICAL Act Now

ABB eSOMS version 6.0.2 may allow unauthorized access to the system when LDAP is set to allow anonymous authentication, and specific key values within the eSOMS web.config file are present. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Abb Esoms +1
NVD
EPSS 0% CVSS 7.8
HIGH This Week

This vulnerability allows local attackers to escalate privileges on vulnerable installations of ABB MicroSCADA 9.3 with FP 1-2-3. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

Authentication Bypass Abb Sys600 Firmware +1
NVD
EPSS 0% CVSS 8.8
HIGH This Week

An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (including Ellipse Select). Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Information Disclosure Abb Ellipse +1
NVD
EPSS 0% CVSS 5.5
MEDIUM This Month

An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. Rated medium severity (CVSS 5.5), this vulnerability is low attack complexity. No vendor patch available.

Information Disclosure Abb Fox515T Firmware +1
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

The embedded web server on ABB Fox515T 1.0 devices is vulnerable to Local File Inclusion. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Abb Fox515T Firmware +1
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy