Microscada X Sys600
CVE-2024-3980
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path canonicalization, traversal prevention
MITRE ATT&CK
2 techniques across 2 tactics: Discovery, Collection The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could access files and directories outside the intended path by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application. Affected products include: Hitachienergy Microscada Pro Sys600, Hitachienergy Microscada X Sys600.
Know when Microscada X Sys600 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.
Affected Products (CPE)NVD
More in Microscada X Sys600
View allThe product exposes a service that is intended for local only to all network interfaces without any authentication. Rate
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. Rated high severity (CVSS 8.8), t
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging suppor
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. Rated h
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP co
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item b
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCA
CVE-2025-39202 is a local privilege escalation vulnerability in MicroSCADA X SYS600's Monitor Pro interface that allows
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. The filtering query in the Web interface
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol a
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB