Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate as high-privilege user
-
ExploitAccess common resource locations
-
ExecutionHarvest exposed sensitive data
-
ImpactExfiltrate disclosed information
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK
2 techniques across 2 tactics: Collection, Discovery The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires an attacker to already hold high-privilege access to the Easy IO Neo controller (CVSS PR:H) and depends on passive user interaction occurring (UI:P); the attacker then reads sensitive data from predictable 'common resource locations' within the product. Limiting factors: the high-privilege authentication requirement and the dependency on user interaction substantially reduce opportunistic exploitation, and the disclosed data impact is Low. Remediation is to upgrade to Easy IO Neo 3.3b63 or later. |
| Impact | This is a medium-severity (CVSS 4.0 base 6.3) information-disclosure flaw (CWE-200) in Johnson Controls Easy IO Neo. The vendor-provided CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:N/VA:L) signals network reachability and low attack complexity, but materially constrains real-world risk through PR:H (high privileges required) and UI:P (passive user interaction required) - meaning an attacker must already hold a high-privilege account AND rely on a victim's incidental interaction. The confidentiality impact is only Low (VC:L), consistent with the description's limited 'collect data from common resource locations.' Notably, the input vector also asserts subsequent-system impacts SC:H/SI:H/SA:H, which is unusual for a pure CWE-200 disclosure issue and appears inconsistent with the Low vulnerable-system impacts and the description - verify these subsequent-system ratings with the vendor advisory, as they heavily inflate the score. No EPSS score, no KEV listing, and no POC were provided; there is no public exploit identified at time of analysis. Overall this is a genuine but lower-priority issue: the high-privilege and user-interaction preconditions, combined with limited direct confidentiality impact and no evidence of exploitation, place it well below internet-facing unauthenticated flaws in remediation urgency. |
| Exploit ScenarioDerived | An attacker who already possesses a high-privilege account on an Easy IO Neo controller leverages the flaw to read sensitive data stored in common/predictable resource locations once a legitimate user interaction occurs. No public proof-of-concept is available, and exploitation yields limited (Low) confidentiality disclosure rather than full system compromise. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 01, 2026
Information disclosure in Johnson Controls Easy IO Neo versions before 3.3b63 allows an authenticated high-privileged attacker to read sensitive data from predictable common resource locations, but requires passive user interaction and yields low confidentiality impact per the independent assessment. This medium-severity flaw (CVSS 4.0 base 6.3, CWE-200) has no public exploit identified at time of analysis. Exploitation depends on the attacker already holding high-privilege access to the controller and on a victim performing passive user interaction, substantially limiting opportunistic exploitation.
RemediationAI
Vendor-released patch: 3.3b63. Upgrade Johnson Controls Easy IO Neo to version 3.3b63 or later as the primary remediation; refer to the vendor advisory at https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories for specific guidance. Until the upgrade can be applied, compensating controls include restricting network access to the controller's management interfaces (e.g., blocking unnecessary ports and limiting source IPs), enforcing least privilege to eliminate or tightly control high-privilege accounts since exploitation requires PR:H, and monitoring for anomalous read operations from common resource locations; these controls may reduce administrative convenience for legitimate users. No public exploit has been identified, but the high privilege requirement and user interaction dependency mean patch deployment should still be prioritized for exposed controllers.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The vulnerability is classified as CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor) and affects the Johnson Controls Easy IO Neo building automation controller, identified by CPE cpe:2.3:a:johnson_controls:easy_io_neo:*:*:*:*:*:*:*:*. The root cause is that the product stores or exposes sensitive data in predictable 'common resource locations' without adequate access controls, allowing an attacker with high privileges to read that data over the network. The provided CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:N/VA:L/SC:H/SI:H/SA:H) indicates network attack vector, high privileges required, passive user interaction, low confidentiality impact, and potential subsequent system impacts; the independent assessment (CVSS 3.1 AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:N/A:N) aligns by requiring high-privilege access and passive user interaction while classifying the confirmed data impact as low with no scope change. No public exploit code or active exploitation has been identified at time of analysis.
Know when Easy Io Neo gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:L/VI:N/VA:L/SC:H/SI:H/SA:H
Network-reachable but needs high-privilege authentication (PR:H) and user interaction (UI:R); CWE-200 yields Low confidentiality only with no integrity or availability impact.
Primary rating from Vendor (jci).
CVSS VectorVendor: jci
Lifecycle Timeline
1DescriptionCVE.org
- Exposure of Sensitive Information vulnerability in Johnson Controls Easy IO Neo allows Collect Data from Common Resource Locations.
This issue affects Easy IO Neo: before 3.3b63.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
EUVD-2026-91073
GHSA-366v-rjm4-rpqp
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB