Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain admin credentials (default, reused, or stolen)
-
DeliveryGain network access to device management interface
-
ExploitSend crafted PUT to /api/iodd/config with injected shell payload
-
ExecutionOS executes payload as root
-
ImpactFull device compromise and potential ICS disruption
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK
2 techniques across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires valid admin-level credentials for the device web management API - exploitation is gated entirely on PR:H authentication. The device management interface must be reachable from the attacker's network position (typical in OT environments where engineering workstations share a management VLAN with field devices). No non-default configuration is required beyond the device being powered on and network-accessible with its web API enabled. What limits exploitation: the mandatory admin credential requirement means unauthenticated internet-facing exploitation is not possible; the typical OT deployment topology places these devices on isolated segments not directly reachable from untrusted networks; and the attack requires knowledge of the specific vulnerable endpoint. |
| Impact | The CVSS 7.2 score with vector AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H is well-calibrated for this vulnerability: network reachability and low attack complexity are offset by the high-privilege prerequisite (valid admin credentials), preventing a higher score. Real-world risk in OT environments is modulated by several factors: IO-Link masters are typically deployed on isolated OT segments, not exposed to the public internet, so the AV:N metric assumes the attacker already has network access to the management interface. The threat model is therefore dominated by insider threats, post-breach lateral movement, or scenarios where the device web interface is reachable from a compromised IT network. Three separate CERT@VDE advisories covering Pepperl+Fuchs, Phoenix Contact, and what appear to be Turck/other OEM variants indicate a shared vulnerable codebase across a broader installed base than a single-vendor reading suggests - even a mid-sized industrial operator in malbork running a mixed-brand IO-Link deployment should treat this as requiring patch prioritization, particularly on devices with management interfaces reachable from engineering workstation VLANs. No public exploit code and no CISA KEV listing reduce urgency, but the unconditional root execution post-authentication and the industrial context (physical process impact potential) keep operational risk elevated. |
| Exploit ScenarioDerived | An attacker who has obtained admin credentials - through password reuse from a compromised engineering workstation, default credential exploitation, or insider access - sends a single crafted HTTP PUT request to the device's /api/iodd/config endpoint with a payload containing shell metacharacters. No public proof-of-concept is known at time of analysis, but the straightforward CWE-78 pattern means exploit development is low effort. The injected command executes as root on the device OS, giving the attacker full control over fieldbus configuration, IO-Link port parameters, and the underlying Linux environment, with potential to disrupt connected sensors and actuators. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Sep 16, 2026
Command injection in the web management API of Pepperl+Fuchs ICE2/ICE3 IO-Link master devices and Phoenix Contact IOL MA8 enables an authenticated admin-level attacker to execute arbitrary OS commands as root via a crafted PUT request to the /api/iodd/config endpoint. All firmware versions of at least nine Pepperl+Fuchs ICE2/ICE3 hardware variants and the Phoenix Contact IOL MA8 PN DI8 are confirmed affected across three CERT@VDE advisories (VDE-2026-014, VDE-2026-027, VDE-2026-028). No public exploit code or active exploitation is identified at time of analysis, but full root compromise of an industrial field device represents a significant ICS/OT risk.
RemediationAI
Consult CERT@VDE advisories VDE-2026-014, VDE-2026-027, and VDE-2026-028 at https://www.certvde.com/en/advisories/ for vendor-issued firmware updates; exact patched firmware versions are not independently confirmable from the available advisory data. Patch availability per vendor advisory should be confirmed directly with Pepperl+Fuchs and Phoenix Contact. As an immediate compensating control, restrict network access to device management interfaces (port 80/443 or the relevant management port) using firewall ACLs, so only authorized engineering workstations on isolated OT VLANs can reach the /api/ endpoints - this directly limits the AV:N attack surface without requiring firmware changes. Additionally, enforce strong, unique admin passwords and disable default credentials on all IO-Link masters; the PR:H requirement means credential hygiene directly gates exploitability. If remote management is not operationally required, disable the web API entirely. Note that restricting network access does not eliminate insider or lateral-movement risk, and should be paired with monitoring for unauthorized PUT requests to /api/iodd/config in OT network traffic logs.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 15 packages in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected devices are IO-Link master modules - industrial field-level hardware that bridges IO-Link sensors and actuators to Ethernet-based fieldbus protocols such as PROFINET and EtherNet/IP. They expose a REST-style management API; the /api/iodd/config endpoint, which handles IODD (IO Device Description) configuration via HTTP PUT, fails to sanitize user-controlled parameters before passing them to an underlying OS shell call. CWE-78 (Improper Neutralization of Special Elements used in an OS Command) is the root cause: attacker-controlled strings are interpolated into a command executed by a root-running web daemon without escaping or allowlist validation. Confirmed affected CPEs include cpe:2.3:a:pepperl+fuchs:ice2-8iol1-g65l-v1d through ice3-8iol-k45s-rj45 and cpe:2.3:a:phoenix_contact:iol_ma8_pn_di8; additional OEM-branded variants (YL212/YN115 series) appear in the advisory tags, suggesting a shared firmware codebase across multiple branded products.
Know when Ice2 8Iol1 G65L V1D gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Admin credentials required (PR:H); network-accessible API endpoint (AV:N); full OS root execution yields C:H/I:H/A:H; scope unchanged on single device.
Primary rating from Vendor (CERTVDE).
CVSS VectorVendor: CERTVDE
Lifecycle Timeline
2DescriptionCVE.org
A high-privileged remote attacker can exploit a command injection vulnerability in the /api/iodd/config endpoint by sending a crafted PUT request with admin credentials allowing execution of commands with root privileges on the device.
Executive ViewAI
Pepperl+Fuchs ICE2/ICE3 and Phoenix Contact IOL MA8 IO-Link master devices contain a command injection vulnerability in the web management API that allows authenticated admin-level users to execute arbitrary OS commands with root privileges. This vulnerability creates critical risk to industrial automation, process control environments, and any manufacturing operations dependent on these field devices. Full device compromise could disrupt production, compromise product quality, or enable lateral movement within industrial control networks.
No vendor-released patch identified at time of analysis. Interim mitigations include: restricting network access to the web management API to dedicated administrative networks or isolated VLANs with firewall enforcement, implementing detailed audit logging of all /api/iodd/config requests for forensic and compliance review, deploying Web Application Firewall rules configured to detect and block command injection payloads, enforcing role-based access controls to limit admin-level authentication to authorized personnel, and establishing compensating controls such as regular manual verification of device configurations and enhanced monitoring for unexpected process execution on affected industrial devices.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
More in Ice2 8Iol1 G65L V1D
View allAuthentication bypass in Pepperl+Fuchs ICE2/ICE3-series IO-Link masters (and OEM-equivalent Phoenix Contact IOL-MA8 modu
Root-level remote code execution affects Pepperl+Fuchs ICE2/ICE3-series and Phoenix Contact IOL-MA8 IO-Link master gatew
Command injection in Pepperl+Fuchs ICE2/ICE3 and Phoenix Contact IOL MA8 series IO-Link Master devices allows a low-priv
Command injection via a PHP web management endpoint on Pepperl+Fuchs ICE2/ICE3 series IO-Link Masters and Phoenix Contac
Command injection via the PHP-based IODD parameter save endpoint on Pepperl+Fuchs ICE2/ICE3 series IO-Link masters and O
Command injection in Pepperl+Fuchs ICE2/ICE3 IO-Link Master devices (and OEM variants from Phoenix Contact and others) a
Command injection via the Field_Shadow_Password class in Pepperl+Fuchs ICE2/ICE3 IO-Link master devices and Phoenix Cont
Command injection in Pepperl+Fuchs ICE2/ICE3 series and Phoenix Contact IOL_MA8 IO-Link master devices enables an authen
Command injection in Pepperl+Fuchs ICE2/ICE3 IO-Link Master devices and OEM equivalents allows a low-privileged authenti
Command injection in Pepperl+Fuchs ICE2/ICE3 IO-Link Master devices (and OEM equivalents from Phoenix Contact and others
Remote code execution is achievable on Pepperl+Fuchs ICE2/ICE3-series IO-Link Master devices and the Phoenix Contact IOL
Remote code execution via PHP local file inclusion on Pepperl+Fuchs ICE2/ICE3 series IO-Link Master devices and OEM equi
EUVD-2026-80245
GHSA-2wvv-pq2h-2gcr
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB