Skip to main content

M300 Wi-Fi Repeater EUVDEUVD-2026-54917

| CVE-2026-19348 HIGH
Command Injection (CWE-77)
2026-08-09 VulDB GHSA-5x4f-6m9q-mg75
8.9
CVSS 4.0 · Vendor: VulDB
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach M300 management HTTP interface
  2. Delivery
    Send crafted GET/POST to /protocol.csp with injected shell metacharacters
  3. Exploit
    sprintf constructs malicious command string
  4. Execution
    Embedded OS executes injected command as privileged process
  5. Impact
    Full device compromise

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

No authentication is required - the CVSS 4.0 PR:N metric confirms the vulnerable endpoint does not enforce access controls. The attacker must have HTTP connectivity to the device's web management interface, which in typical SOHO deployments is accessible on the LAN segment. Internet-exposed management interfaces (common on misconfigured repeaters or those with WAN-side HTTP enabled) expand the attacker population to the full internet. No special configuration, feature flag, or specific firmware mode is required beyond the device running the affected firmware and the management interface being reachable. Exploitation is limited by: (1) network reachability to the management port, and (2) the relatively niche deployment footprint of the M300 device itself.

Impact

The CVSS 4.0 base score of 8.9 with vector AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H accurately captures the severity: unauthenticated, zero-complexity, remote exploitation yielding full device compromise. The E:P modifier (proof-of-concept public) in the CVSS 4.0 environmental data is consistent with the GitHub exploit repository, and materially increases near-term exploitation probability. No EPSS score was provided in the intelligence data - this is a gap; without it, probabilistic prioritization against other CVEs is not possible from the available data. The device's SOHO deployment profile limits blast radius compared to enterprise infrastructure CVEs, but internet-exposed management interfaces on home or branch-office repeaters are routinely targeted by botnets and mass-scanning campaigns. The absence of a vendor patch and the public exploit together make this a high-urgency item for any network where M300 units are deployed with reachable management interfaces.

Exploit ScenarioDerived

An unauthenticated attacker reachable to the M300's web management interface sends a crafted HTTP request to /protocol.csp?fname=net&opt=smacfilter_conf&function=set&act=add&name=test%3Bwhoami&enable=1&mac=00:00:00:00:00:00, injecting a shell command via the name parameter. The firmware's sprintf call constructs a command string incorporating the unsanitized semicolon-delimited payload, which the underlying OS executes. A public proof-of-concept at https://github.com/IEATASICS/m300-repeater-bugs is available, meaning this attack requires minimal technical skill.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
1 PoC candidate (unverified) No patch listed yet 2.5% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Aug 09, 2026

Remote command injection in the Shenzhen Aitemi M300 Wi-Fi Repeater (firmware r0-ea7890a) enables unauthenticated network-adjacent attackers to execute arbitrary OS commands by manipulating the enable, name, or mac parameters of the MAC address filter configuration CGI endpoint. The vulnerable sprintf call in the protocol.csp handler passes user-supplied input directly into a shell command string without sanitization. A public proof-of-concept exploit has been published on GitHub, significantly lowering the exploitation barrier, though no CISA KEV listing has been identified at time of analysis.

Earlier versions of this analysis (1)
v1 Aug 09, 2026 - 11:20 CVSS 9.3

Command injection in the Shenzhen Aitemi M300 Wi-Fi Repeater (firmware r0-ea7890a) lets remote attackers run arbitrary OS commands by manipulating the enable, name, or mac parameters of the smacfilter_conf 'add' action in the /protocol.csp web endpoint. The flaw stems from unsanitized input passed to a sprintf-built command string; exploit code is publicly available, and CVSS 4.0 scores it 9.3 (Critical) with no authentication or user interaction required.

RemediationAI

No vendor-released patch has been identified at time of analysis. The immediate priority is to restrict access to the device's web management interface: place the repeater behind a firewall and apply ACLs blocking access to the /protocol.csp endpoint and the management port (typically TCP 80/8080) from all untrusted network segments, including the WAN interface if applicable - this eliminates remote exploitation but does not address LAN-side attackers. If the management interface cannot be isolated, consider disabling the MAC address filtering feature entirely if it is not operationally required, which removes the specific vulnerable code path (trade-off: loss of MAC filter functionality). Device replacement with a supported product from a vendor with an active security response program should be evaluated, given the absence of any vendor advisory or patch commitment. Monitor https://vuldb.com/vuln/387184 for patch availability updates.

Affected VersionsENISA

M300 Wi-Fi Repeater r0-ea7890a

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected product is identified by CPE cpe:2.3:a:shenzhen_aitemi:m300_wi-fi_repeater:*:*:*:*:*:*:*:*, covering all known versions of the Shenzhen Aitemi M300 Wi-Fi Repeater. The root cause is CWE-77 (Improper Neutralization of Special Elements used in a Command), a classic embedded firmware pattern where a C-level sprintf call constructs a shell command string by concatenating user-controlled HTTP parameters - enable, name, and mac - without escaping shell metacharacters. The vulnerable CGI endpoint is /protocol.csp?fname=net&opt=smacfilter_conf&function=set&act=add, which handles the addition of MAC address filter entries. This pattern is prevalent in SOHO router and repeater firmware where web-to-shell bridges are implemented without input validation, and the injected commands execute with whatever privileges the CGI process runs under - typically root on embedded Linux.

Know when M300 Wi Fi Repeater gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (VulDB) PRIMARY 8.9 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
vuln.today AI 9.8 CRITICAL

Network-reachable CGI endpoint with no authentication (consistent with CVSS 4.0 PR:N), no complexity barriers, and full device compromise with no scope change beyond the affected repeater.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (VulDB).

CVSS VectorVendor: VulDB

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

4
Analysis Updated
Aug 09, 2026 - 11:29 vuln.today
v2 - CVSS changed
Severity Changed
Aug 09, 2026 - 11:22 NVD
CRITICAL HIGH
CVSS changed
Aug 09, 2026 - 11:22 NVD
9.3 (CRITICAL) 8.9 (HIGH)
CVE Published
Aug 09, 2026 - 10:30 cve.org
CRITICAL 9.3

DescriptionCVE.org

A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilter_conf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command injection. The attack may be initiated remotely. The exploit has been released to the public and may be used for attacks.

Latest POC

1 PoC candidate from github (unverified)

Sign in to open the public PoC links collected for this CVE.

Executive ViewAI

Why It Matters

The Shenzhen Aitemi M300 Wi-Fi Repeater (firmware r0-ea7890a) contains a critical remote command injection vulnerability (CVE-2026-19348) allowing unauthenticated attackers to execute arbitrary OS commands and gain complete device control. Publicly available exploit code exists, significantly lowering the technical barrier to attack, and no vendor patch is available. Organizations with deployed Aitemi M300 devices face immediate risk of network compromise and require urgent remediation.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Isolate affected devices to segregated networks with restricted access; implement network segmentation limiting trust from these devices; deploy network-based monitoring for anomalous activity and command execution patterns; prioritize device replacement with vendors providing active security patches.

Threat Intelligence Overview

EPSS Score
2.5%
Top 17% exploitable
Prevalence
Low
niche consumer SOHO repeater from a minor Chinese OEM vendor
Social Media
3
Sightings
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 2.5%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
High

Priority Score

66
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.