Skip to main content

Phoenix Contact CHARX EUVDEUVD-2026-51029

| CVE-2026-44094 HIGH
Not Failing Securely ('Failing Open') (CWE-636)
2026-07-30 info@cert.vde.com GHSA-vqrq-f9p4-xrm2
8.3
CVSS 4.0 · Vendor: cert
Share

Severity by source

Vendor (cert) PRIMARY
8.3 HIGH
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
7.0 HIGH

Network-reachable and unauthenticated (AV:N/PR:N) but requires forcing the fallback condition (AC:H); unprivileged 'user-app' access gives low C/I, while charging interruption drives A:H.

3.1 AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H
4.0 AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (cert).

CVSS VectorVendor: cert

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

3
Analysis Generated
Jul 30, 2026 - 08:36 vuln.today
Patch available
Jul 30, 2026 - 08:03 EUVD
CVE Published
Jul 30, 2026 - 07:16 cve.org
HIGH 8.3

DescriptionCVE.org

An unauthenticated remote attacker can enforce the system to fall back to a firmware partition with an insecure configuration including default credentials. This could allow the attacker to gain SSH access to the system as an unprivileged user "user-app". Charging could be interrupted.

AnalysisAI

Insecure firmware-fallback in Phoenix Contact CHARX SEC EV charging controllers (SEC-3000, SEC-3050, SEC-3100, SEC-3150, versions 1.0.0 up to 1.9.1) lets a remote unauthenticated attacker force the device to boot an alternate firmware partition that ships with an insecure configuration and default credentials, yielding SSH access as the unprivileged 'user-app' account and allowing charging to be interrupted. The issue was reported by CERT@VDE (VDE-2026-008 / EUVD-2026-51029) and carries a CVSS 4.0 base score of 8.3, driven by high availability impact. No public exploit identified at time of analysis, and it is not listed in CISA KEV.

Technical ContextAI

The affected devices are CHARX SEC series charging controllers used to manage AC EV charging stations. The root cause is CWE-636 (Not Failing Securely / 'Failing Open'): the firmware update and recovery mechanism includes a fallback partition that is intended for recovery but is provisioned with a hardened-less, insecure default configuration - including default credentials that enable SSH login as the low-privilege 'user-app' user. Because an attacker can remotely trigger the fallback to this partition, a security mechanism (the primary hardened firmware) degrades to an insecure state rather than failing closed. Per the EUVD/NVD CPE data the flaw affects CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 across firmware 1.0.0 through versions below 1.9.1.

RemediationAI

Vendor-released patch: upgrade all affected CHARX SEC-3000/3050/3100/3150 controllers to firmware version 1.9.1 or later, which is available from the vendor per advisory VDE-2026-008 (https://www.certvde.com/en/advisories/VDE-2026-008/). Until patching is possible, restrict network access to the charger's management and SSH interfaces by placing devices on an isolated management VLAN or behind a firewall so that the fallback-triggering network path is not reachable by untrusted parties (trade-off: legitimate remote management must be tunneled or whitelisted); where feasible, disable or block external SSH access to prevent login via the 'user-app' default credentials (trade-off: loss of remote shell administration). Because the default credentials live in the fallback firmware image, changing runtime credentials on the primary partition does not fully mitigate - patching to 1.9.1 is the only reliable fix.

Share

EUVD-2026-51029 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy