Skip to main content

mbCONNECT24 EUVDEUVD-2026-38422

| CVE-2026-10521 HIGH
Direct Request ('Forced Browsing') (CWE-425)
2026-06-23 CERTVDE GHSA-vwqx-9g89-x938
8.6
CVSS 4.0 · Vendor: CERTVDE
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Obtain high-privileged portal credentials
  2. Delivery
    Authenticate to mbCONNECT24 management interface
  3. Exploit
    Send request to hidden configuration method
  4. Execution
    Modify critical program parameters
  5. Impact
    Pivot or disrupt downstream OT access

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Direct request prevention
Exploitation Conditions

Exploitation requires the attacker to already hold a high-privileged authenticated session on mbCONNECT24 or mymbCONNECT24 (PR:H) and to send a request to a hidden, undocumented configuration method that the product does not expose in its normal UI - knowledge of the endpoint path/parameters is therefore a practical prerequisite. No user interaction is needed (UI:N) and no additional attack requirements apply (AT:N), but the requirement for an existing high-privilege account is the dominant limiting factor: unauthenticated internet attackers cannot reach this issue directly, and exposure is bounded to deployments where admin credentials can be compromised or are held by an untrusted insider.

Impact

The CVSS 4.0 vector AV:N/AC:L/AT:N/PR:H/UI:N with VC:H/VI:H/VA:H produces a base score of 8.6, reflecting full CIA impact reachable over the network without user interaction but gated by high privileges. There is no CISA KEV listing, no EPSS score, and no public proof-of-concept supplied, so this is currently a high-severity but not demonstrably exploited issue - the realistic threat model is an insider, a compromised admin account, or post-authentication lateral movement rather than mass internet scanning. Because mbCONNECT24 brokers remote access into ICS/OT environments, even an authenticated-only flaw is meaningful: an attacker who has already obtained admin credentials could pivot through the hidden method to push configuration changes that downstream affect industrial assets. Confidence in attack vector AV:N is reasonable given the product's web/portal nature, but absence of EPSS and KEV data should not be read as 'low risk' for OT operators.

Exploit ScenarioDerived

An attacker who has obtained or already holds a high-privilege account on mbCONNECT24 - for example via phishing of an OT administrator, credential reuse, or insider access - sends a crafted request directly to the undocumented configuration endpoint over the network. Because the platform does not gate this method even from authenticated users, the attacker rewrites critical program parameters, which can be leveraged to disrupt remote-access policies, redirect connections, or stage further intrusion into the downstream industrial network. No public exploit identified at time of analysis, so any exploitation would currently rely on independent discovery of the hidden endpoint.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Jun 23, 2026

Privileged remote modification of critical program parameters in MB connect line mbCONNECT24 and mymbCONNECT24 allows authenticated high-privilege attackers to reach a hidden configuration method that should be inaccessible to any user, resulting in total compromise of confidentiality, integrity, and availability. No public exploit identified at time of analysis, and the issue was coordinated through CERT@VDE under advisory VDE-2026-068.

RemediationAI

Patch available per vendor advisory - operators should consult CERT@VDE advisory VDE-2026-068 at https://www.certvde.com/en/advisories/VDE-2026-068/ for the exact fixed mbCONNECT24 / mymbCONNECT24 build and upgrade to it; no specific fixed version is enumerated in the input data so do not assume a number. Until the patched version is deployed, compensating controls should focus on restricting who can authenticate as a high-privileged user: enforce MFA on all administrator accounts, prune unused admin and operator accounts, rotate admin credentials, and restrict management-plane access to the portal to a small set of source IPs via firewall or VPN allowlist so the hidden configuration method cannot be reached even by stolen credentials from arbitrary networks. Enable and monitor audit logs for configuration-change events and unexpected access to administrative endpoints; the side effect of the network restriction is reduced remote-admin convenience, and the side effect of credential restrictions is additional account-management overhead.

Affected VersionsENISA

mbCONNECT24 2.20.1
mymbCONNECT24 2.20.1
mbCONNECT24 0.0.0 <2.20.2
mymbCONNECT24 0.0.0 <2.20.2

Affected Packages

euvd mbconnect24 fix: 2.20.2
euvd mymbconnect24 fix: 2.20.2

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 2 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

mbCONNECT24 and mymbCONNECT24 are remote-maintenance and industrial VPN portal products from MB connect line, widely used to provide secure remote access to OT/ICS equipment such as PLCs and HMIs. The flaw is classified as CWE-425 (Direct Request / Forced Browsing): an internal configuration endpoint is reachable directly by URL or API call without the platform enforcing that the function is off-limits, even to high-privileged accounts. Although high privileges are required to invoke it per the CVSS vector, the function itself was never intended to be exposed and bypasses the product's normal configuration governance, letting the caller alter critical operational parameters that would normally be locked down.

Know when Mymbconnect24 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (CERTVDE) PRIMARY 8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.2 HIGH

Network-reachable management endpoint with low complexity but requires existing high-privilege account (PR:H); full CIA impact on the portal, no scope change.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (CERTVDE).

CVSS VectorVendor: CERTVDE

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

1
Patch available
Jun 23, 2026 - 09:16 EUVD

DescriptionCVE.org

An high privileged remote attacker can access a hidden configuration method, that should not be accessible by any user, to modify critical program parameters. This can result in a total loss of confidentiality, integrity and availability.

Executive ViewAI

Why It Matters

mbCONNECT24 and mymbCONNECT24 contain a high-severity vulnerability enabling privileged users to bypass system safeguards and modify critical parameters, potentially compromising all operational data and system availability. Organizations relying on these industrial connectivity products lack vendor patches to address the risk, requiring emergency access controls. The threat profile resembles insider risk-privileged abuse or credential compromise becomes a direct channel to total system compromise.

Business Impact: High
Compensating Controls

Implement strict role-based access controls limiting administrative functions to essential personnel only; enforce multi-factor authentication for all high-privilege accounts; isolate administrative management interfaces to dedicated trusted networks; deploy continuous audit logging and real-time monitoring of privilege escalation attempts; restrict and background-check personnel granted administrative access; establish privileged access management (PAM) solution to control, monitor, and log all administrative sessions.

Threat Intelligence Overview

EPSS Score
0.3%
Top 78% exploitable
Prevalence
Low
niche industrial remote-access portal, OT/ICS-specific deployment footprint
Social Media
5
Sightings
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.3%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

43
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +43
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

CVE-2026-32968 CRITICAL
9.8 Mar 23

This is a critical OS command injection vulnerability in the com_mb24sysapi module of several MB Connect Line and Helmho

CVE-2020-10383 CRITICAL
9.8 Apr 14

An issue was discovered in the MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 software in all versions through 2.5.0. Rat

CVE-2026-33615 CRITICAL
9.1 Apr 02

SQL injection in MB Connect Line's mbCONNECT24 and mymbCONNECT24 platforms allows unauthenticated remote attackers to ex

CVE-2026-33613 HIGH
8.8 Apr 02

Remote code execution in MB Connect Line mbCONNECT24 and mymbCONNECT24 allows high-privileged authenticated attackers to

CVE-2023-0985 HIGH
8.8 Jun 06

An Authorization Bypass vulnerability was found in MB Connect Lines mbCONNECT24, mymbCONNECT24 and Helmholz' myREX24 and

CVE-2020-10382 HIGH
8.8 Apr 14

An issue was discovered in the MB CONNECT LINE mymbCONNECT24 and mbCONNECT24 software in all versions through 2.5.0. Rat

CVE-2026-60040 HIGH
8.7 Nov 10

Unauthenticated denial of service in mbCONNECT24, mymbCONNECT24, myREX24V2, and myREX24V2.virtual from 2.0.0 up to but n

CVE-2026-60046 HIGH
8.7 Nov 10

Unauthenticated password-reset abuse in mbCONNECT24 and related MB Connect Line/Helmholz products (2.0.0 before 2.21.0)

CVE-2026-60044 HIGH
8.7 Nov 10

Backups generated by mbCONNECT24, mymbCONNECT24, myREX24V2, and myREX24V2.virtual versions 2.0.0 up to but not including

CVE-2026-60039 HIGH
8.6 Nov 10

Code injection in the backup/restore function of mbCONNECT24, mymbCONNECT24, myREX24V2 and myREX24V2.virtual before 2.21

CVE-2026-60038 HIGH
8.6 Nov 10