| CVE-2026-46749 MEDIUM
Use of a One-Way Hash with a Predictable Salt (CWE-760)
2026-06-09 siemens GHSA-c5mx-3x5g-xmjx
5.0
CVSS 4.0 · Vendor: siemens
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Recon
    Gain high-privilege local access to SINEC INS host
  2. Delivery
    Extract password hash store from application data directory
  3. Exploit
    Identify static salt from application binary or known salt value
  4. Install
    Generate rainbow table or run GPU brute-force against extracted hashes
  5. C2
    Recover plaintext user credentials
  6. Execute
    Authenticate to SINEC INS as legitimate user
  7. Impact
    Manipulate industrial network configuration or pivot to downstream OT systems

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A04:2025 - Cryptographic Failures
ASVS 5.0
V11 - Cryptography Unpredictable hash salts
Exploitation Conditions

Exploitation requires local access to the SINEC INS host (AV:L) with high privileges sufficient to read the application's password hash store (PR:H). The CVSS 4.0 vector also specifies AT:P, indicating specific deployment prerequisites must be present - likely that the application is configured with user accounts whose hashes are stored using the vulnerable implementation. The static salt is a global property of the application, so no special per-deployment misconfiguration is required beyond the application being installed in an affected version. Factors limiting exploitation: the attacker must already have high-privileged local access, meaning this vulnerability is not independently exploitable from the network; it functions as a credential escalation or persistence mechanism following initial access. Remote, unauthenticated exploitation is not supported by the CVSS vector. Specific non-default configurations are not required - the weak hashing appears to be the default implementation in all affected versions.

Impact

The CVSS 4.0 base score of 4.9 reflects significant attack constraints: AV:L (local access required), AC:H (high attack complexity), AT:P (specific prerequisites must be present), and PR:H (high privileges required to access the hash store). These preconditions sharply limit opportunistic exploitation. However, the subsequent system impact scores - SC:H, SI:H, SA:H - reveal the true downstream risk: once credentials are recovered, an attacker can achieve high-impact compromise of systems beyond the vulnerable host itself, which is consistent with SINEC INS's role as a network management platform with broad reach into industrial infrastructure. EPSS data was not provided in the source intelligence, so exploitation probability cannot be quantified. The vulnerability is not listed in CISA KEV and no POC has been identified. The realistic risk profile is therefore: low probability of exploitation by opportunistic attackers due to the AV:L/PR:H barrier, but high severity for insider threats, post-breach lateral movement scenarios, or cases where a lower-severity initial access vulnerability is chained to reach the hash store. The 'Authentication Bypass' tag reflects the ultimate impact rather than the mechanism.

Exploit ScenarioDerived

An insider or post-compromise attacker with high-privileged local access to a SINEC INS host extracts the application's password database. Because all installations share the same hardcoded salt, the attacker pre-computes a rainbow table offline (or runs a GPU-accelerated brute-force attack) and recovers plaintext credentials for multiple user accounts within a feasible timeframe. The recovered credentials are then used to log into SINEC INS with legitimate user identities, granting access to industrial network management capabilities and potentially enabling reconfiguration of connected infrastructure. No public POC has been identified, but the attack technique is well-understood and requires no novel research.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Jun 09, 2026

Weak password hashing in Siemens SINEC INS (all versions prior to V1.0 SP2 Update 6) exposes stored credentials to efficient offline recovery due to a static, hardcoded salt shared universally across all users and installations, combined with an insufficient iteration count. An attacker who has obtained high-privileged local access and can extract the password store can leverage the known static salt to construct targeted rainbow tables or run accelerated brute-force attacks, potentially recovering plaintext passwords and achieving unauthorized access to the application and downstream industrial network infrastructure. No public exploit code or CISA KEV listing has been identified at time of analysis, but the cryptographic weakness is deterministic - once hashes are obtained, the static salt eliminates per-user uniqueness and dramatically reduces attack cost.

RemediationAI

Vendor-released patch: V1.0 SP2 Update 6. Organizations running SINEC INS should upgrade to V1.0 SP2 Update 6 or later as the primary remediation, following guidance in Siemens ProductCERT advisory SSA-860189 at https://cert-portal.siemens.com/productcert/html/ssa-860189.html. If immediate patching is not feasible, organizations should treat all existing stored credentials in SINEC INS as potentially compromised and force password resets for all users, selecting long, high-entropy passwords to increase offline brute-force cost despite the weak hashing. As a compensating control, restrict access to the SINEC INS application and its underlying data store to only explicitly authorized, least-privilege accounts; this directly addresses the AV:L/PR:H prerequisite for exploitation. Network segmentation should be enforced to limit the blast radius if credentials are recovered and used for lateral movement into connected industrial systems. Note that password resets alone do not fix the underlying cryptographic weakness - they only raise the per-password attack cost transiently.

Affected VersionsENISA

SINEC INS 0 <V1.0 SP2 Update 6

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

SINEC INS (Infrastructure Network Services) is a Siemens industrial network management platform used in OT/ICS environments. The vulnerability is classified under CWE-760 (Use of a One-Way Hash with a Predictable Salt), which describes the failure mode where a cryptographic hash function is applied to passwords using a salt value that is either static, hardcoded, or shared - negating the primary security benefit of salting. The affected CPE string (cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*) covers all versions of the application prior to V1.0 SP2 Update 6. Because every installation uses the same salt, an attacker who extracts hashes from any deployment can precompute a single rainbow table applicable to all deployments globally. The insufficient iteration count compounds the weakness by allowing faster per-guess processing on commodity hardware or GPUs. Together, these flaws reduce a hash-based credential store to something functionally similar to an unsalted MD5 database in terms of offline attack resistance.

Know when Sinec Ins gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 5.0 MEDIUM
CVSS:4.0/AV:L/AC:H/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:H/SI:H/SA:H

Primary rating from Vendor (siemens) · only source for this CVE.

CVSS VectorVendor: siemens

Attack Vector
Local
Attack Complexity
High
Attack Requirements
Present
Privileges Required
High
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
None
Vulnerable system: Availability
None
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

Lifecycle Timeline

3
CVSS changed
Oct 23, 2026 - 22:23 NVD
4.9 (MEDIUM) 5.0 (MEDIUM)
Severity Changed
Jun 09, 2026 - 10:22 NVD
HIGH MEDIUM
CVSS changed
Jun 09, 2026 - 10:22 NVD
7.5 (HIGH) 4.9 (MEDIUM)

DescriptionCVE.org

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.

Threat Intelligence Overview

EPSS Score
0.0%
Top 98% exploitable
Threat Intel
1
1 source
Social Media
1
Sightings
Data Quality
7 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.0%
Patch available No
Active threat Yes
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation
None
System Exposure· derived
Small
Automatable
No
Human Impact· derived
Medium
Technical Impact
Total

Priority Score

35
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +25
PoC: 0
Weaponized: 0
Threat intel: +10
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Related Vulnerabilities in SINEC INS Privilege and Password Hashing Flaws

View all 2
CVE-2022-2068 HIGH
7.3 Jun 21

In addition to the c_rehash shell command injection identified in CVE-2022-1292, further circumstances where the c_rehas

CVE-2021-23337 HIGH POC
7.2 Feb 15

Lodash versions prior to 4.17.21 are vulnerable to Command Injection via the template function. Rated high severity (CVS

CVE-2021-22945 CRITICAL POC
9.1 Sep 23

When sending data to an MQTT server, libcurl <= 7.73.0 and 7.78.0 could in some circumstances erroneously keep a pointer

CVE-2022-35255 CRITICAL POC
9.1 Dec 05

A weak randomness in WebCrypto keygen vulnerability exists in Node.js 18 due to a change with EntropySource() in SecretK

CVE-2020-12762 HIGH POC
7.8 May 09

json-c through 0.14 has an integer overflow and out-of-bounds write via a large JSON file, as demonstrated by printbuf_m

CVE-2021-3749 HIGH POC
7.5 Aug 31

axios is vulnerable to Inefficient Regular Expression Complexity. Rated high severity (CVSS 7.5), this vulnerability is

CVE-2020-7793 HIGH POC
7.5 Dec 11

The package ua-parser-js before 0.7.23 are vulnerable to Regular Expression Denial of Service (ReDoS) in multiple regexe

CVE-2021-25217 HIGH POC
7.4 May 26

In ISC DHCP 4.1-ESV-R1 -> 4.1-ESV-R16, ISC DHCP 4.4.0 -> 4.4.2 (Other branches of ISC DHCP (i.e., releases in the 4.0.x

CVE-2026-46746 HIGH
8.7 Jun 09

Authenticated command injection in Siemens SINEC INS versions prior to V1.0 SP2 Update 6 allows remote attackers to exec

CVE-2022-35256 MEDIUM POC
6.5 Dec 05

The llhttp parser in the http module in Node v18.7.0 does not correctly handle header fields that are not terminated wit

CVE-2022-32215 MEDIUM POC
6.5 Jul 14

The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does not correctly handle multi-line T

Threat IntelligenceMISP

CISA Advisories
Sources: CISA (public domain)

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy