Skip to main content

Tenda EUVD-2026-35179

| CVE-2026-11556 HIGH
OS Command Injection (CWE-78)
2026-06-08 VulDB GHSA-47fv-fgr6-m346
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Jun 08, 2026 - 18:32 vuln.today
CVSS changed
Jun 08, 2026 - 18:22 NVD
8.8 (HIGH) 7.4 (HIGH)

DescriptionCVE.org

A security flaw has been discovered in Tenda F451 1.0.0.7/1.0.0.9. Impacted is the function formWriteFacMac of the file /goform/WriteFacMac of the component Web Management Interface. Performing a manipulation of the argument mac results in os command injection. Remote exploitation of the attack is possible. The exploit has been released to the public and may be used for attacks.

AnalysisAI

OS command injection in Tenda F451 routers (firmware 1.0.0.7 and 1.0.0.9) allows remote attackers with low-privileged web management access to execute arbitrary operating system commands by manipulating the 'mac' parameter sent to the /goform/WriteFacMac endpoint handled by the formWriteFacMac function. Publicly available exploit code exists, raising the practical risk for any device exposing the web management interface to untrusted networks. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Recommended ActionAI

Within 24 hours: Audit all Tenda F451 devices in production; immediately restrict web management interface access to trusted administrative networks only and disable remote access if possible. …

Sign in for detailed remediation steps and compensating controls.