Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain adjacent-network access to charger
-
DeliverySend unauthenticated POST/PUT to web server
-
ExploitBrute-force configid value
-
ExecutionSet service password / change settings
-
ImpactFull device control or reboot (DoS)
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication required for critical functions
MITRE ATT&CK
1 technique across 1 tactic: Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires adjacent-network access (AV:A) to the UFC500's web server - the attacker must reach the device over the local/adjacent network segment, not the open internet. No authentication is required (PR:N) and no user interaction (UI:N), so the reboot action works against default configurations of the Delta UFC500 by any party who can send HTTP POST/PUT to the interface. The more impactful capability - setting the service password and changing arbitrary settings - additionally requires brute-forcing the configid value, which is the one practical limiting factor; network segmentation or isolating the charger's management interface from untrusted hosts substantially reduces realistic exposure. |
| Impact | This is a genuine high-severity authentication bypass (CWE-306, missing authentication for critical functions) but several signals temper the urgency. The CVSS 4.0 base score of 8.7 is driven by PR:N/UI:N (no authentication, no user interaction) combined with high confidentiality and integrity impact (VC:H/VI:H) and partial availability impact (VA:L). Critically, the attack vector is AV:A (Adjacent), NOT network/internet-wide - exploitation requires the attacker to be on the same local or adjacent network segment as the charger's web interface, which meaningfully constrains the exposed population versus a true remote (AV:N) flaw. The DIVD/vuln.today SSVC-style decision label is 'this_week', indicating prompt but not emergency remediation. No EPSS score was provided, the CVE is NOT in CISA KEV (no confirmed active exploitation), and no proof-of-concept or exploit reference is present in the input. The signals are therefore internally consistent rather than conflicting: high technical impact and trivial complexity (AC:L, AT:N) justify the elevated score, while the adjacent-only vector plus absence of KEV/EPSS/PoC indicate this is a serious issue for exposed OT/EV-charging networks rather than evidence of widespread opportunistic exploitation. Note the two-tier impact: rebooting the charger is trivially unauthenticated, while full setting modification additionally requires brute-forcing the configid value, a modest added barrier. |
| Exploit ScenarioDerived | An attacker with access to the same network segment as the Delta UFC500 charger (e.g., a compromised device on the OT/charging LAN) sends an unauthenticated POST or PUT request to the web server to reboot the unit, causing denial of service. To escalate, the attacker brute-forces the configid parameter, sets the service password, and then modifies any device setting to take full administrative control. No public exploit code is identified at the time of analysis, so this would require custom tooling against the device's HTTP interface. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 30, 2026
Delta UFC500 chargers expose web server POST and PUT actions without authentication, allowing an attacker on the adjacent network to reboot the device and, if the configid can be brute-forced, set the service password and alter arbitrary settings. The flaw is a CWE-306 missing-authentication issue rated CVSS 8.7, with high confidentiality and integrity impact and lower availability impact; the independent assessment notes that network segmentation or isolating the charger management interface materially reduces realistic exposure. No public exploit identified at time of analysis, and the vuln.today decision label is this_week.
RemediationAI
No vendor-released patch or fixed version is identified in the provided data; consult the DIVD advisory at https://csirt.divd.nl/DIVD-2026-00012 and the CVE page at https://csirt.divd.nl/CVE-2026-22110 for updated remediation guidance. Until a fix is available, place the UFC500 management interface on a dedicated VLAN or firewall it so only trusted administrative hosts can reach the web server, and block HTTP POST and PUT from untrusted network segments; this reduces adjacent-network exposure but limits remote administration and may break legitimate configuration changes. Restrict physical and network access to the charger segment and monitor for unauthorized reboot or configuration-change requests as compensating controls. If configid is configurable, strengthen or rotate it and the service password, but that does not prevent the unauthenticated reboot and is not a substitute for a vendor fix.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The Delta UFC500 web server performs state-changing operations through HTTP POST and PUT but does not enforce authentication on those methods, which is CWE-306 (Missing Authentication for Critical Function). The CVSS 4.0 vector describes adjacent-network access (AV:A), low attack complexity, no privileges and no user interaction, with high confidentiality and integrity impact and low availability impact; the independent CVSS 3.1 assessment agrees on adjacent access, unauthenticated exploitation and high confidentiality and integrity impact. Rebooting is directly reachable by any party able to send POST or PUT requests to the interface, while setting the service password and changing other settings is gated by the configid value that must be brute-forced according to the description. The available sources do not describe the exact request format or the length and entropy of configid.
Know when Delta Ufc500 gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
Adjacent-network web server with no authentication (AV:A, PR:N, AC:L); arbitrary setting/password change gives C:H/I:H, while reboot is a partial availability impact (A:L).
Primary rating from Vendor (DIVD).
CVSS VectorVendor: DIVD
Lifecycle Timeline
2DescriptionCVE.org
The web server does not check authentication on POST or PUT. An unauthenticated attacker can reboot the charger; by brute-forcing the configid, they can also set the service password and then change any setting.
Executive ViewAI
Delta UFC500 electric vehicle chargers contain a high-severity authentication bypass that allows attackers on the adjacent network to reboot devices and, with brute-forcing, alter critical settings including service passwords. This could disrupt charging operations and compromise configuration integrity, impacting site reliability and customer trust. Leadership should prioritize mitigation due to the potential for service outages and unauthorized control over charging infrastructure.
Network segmentation to isolate charger management interfaces, restrict adjacent network access, monitor for anomalous POST/PUT requests, and enforce strong credentials.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
More in Delta Ufc500
View allDelta UFC500 charging stations generate the Service-account password from fixed character positions of the device serial
Cleartext storage of universal factory default passwords in the Delta UFC500 WebUI template database lets an authenticat
Delta UFC500 devices can be brute-forced through their HTTP basic authentication endpoint because the service enforces n
EUVD-2026-113765
GHSA-5fcx-qv97-pcff
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB