Skip to main content

Delta UFC500 CVE-2026-22110

| EUVDEUVD-2026-113765 HIGH
Missing Authentication for Critical Function (CWE-306)
2026-10-30 DIVD GHSA-5fcx-qv97-pcff
8.7
CVSS 4.0 · Vendor: DIVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain adjacent-network access to charger
  2. Delivery
    Send unauthenticated POST/PUT to web server
  3. Exploit
    Brute-force configid value
  4. Execution
    Set service password / change settings
  5. Impact
    Full device control or reboot (DoS)

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication required for critical functions
MITRE ATT&CK

1 technique across 1 tactic: Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires adjacent-network access (AV:A) to the UFC500's web server - the attacker must reach the device over the local/adjacent network segment, not the open internet. No authentication is required (PR:N) and no user interaction (UI:N), so the reboot action works against default configurations of the Delta UFC500 by any party who can send HTTP POST/PUT to the interface. The more impactful capability - setting the service password and changing arbitrary settings - additionally requires brute-forcing the configid value, which is the one practical limiting factor; network segmentation or isolating the charger's management interface from untrusted hosts substantially reduces realistic exposure.

Impact

This is a genuine high-severity authentication bypass (CWE-306, missing authentication for critical functions) but several signals temper the urgency. The CVSS 4.0 base score of 8.7 is driven by PR:N/UI:N (no authentication, no user interaction) combined with high confidentiality and integrity impact (VC:H/VI:H) and partial availability impact (VA:L). Critically, the attack vector is AV:A (Adjacent), NOT network/internet-wide - exploitation requires the attacker to be on the same local or adjacent network segment as the charger's web interface, which meaningfully constrains the exposed population versus a true remote (AV:N) flaw. The DIVD/vuln.today SSVC-style decision label is 'this_week', indicating prompt but not emergency remediation. No EPSS score was provided, the CVE is NOT in CISA KEV (no confirmed active exploitation), and no proof-of-concept or exploit reference is present in the input. The signals are therefore internally consistent rather than conflicting: high technical impact and trivial complexity (AC:L, AT:N) justify the elevated score, while the adjacent-only vector plus absence of KEV/EPSS/PoC indicate this is a serious issue for exposed OT/EV-charging networks rather than evidence of widespread opportunistic exploitation. Note the two-tier impact: rebooting the charger is trivially unauthenticated, while full setting modification additionally requires brute-forcing the configid value, a modest added barrier.

Exploit ScenarioDerived

An attacker with access to the same network segment as the Delta UFC500 charger (e.g., a compromised device on the OT/charging LAN) sends an unauthenticated POST or PUT request to the web server to reboot the unit, causing denial of service. To escalate, the attacker brute-forces the configid parameter, sets the service password, and then modifies any device setting to take full administrative control. No public exploit code is identified at the time of analysis, so this would require custom tooling against the device's HTTP interface.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 30, 2026

Delta UFC500 chargers expose web server POST and PUT actions without authentication, allowing an attacker on the adjacent network to reboot the device and, if the configid can be brute-forced, set the service password and alter arbitrary settings. The flaw is a CWE-306 missing-authentication issue rated CVSS 8.7, with high confidentiality and integrity impact and lower availability impact; the independent assessment notes that network segmentation or isolating the charger management interface materially reduces realistic exposure. No public exploit identified at time of analysis, and the vuln.today decision label is this_week.

RemediationAI

No vendor-released patch or fixed version is identified in the provided data; consult the DIVD advisory at https://csirt.divd.nl/DIVD-2026-00012 and the CVE page at https://csirt.divd.nl/CVE-2026-22110 for updated remediation guidance. Until a fix is available, place the UFC500 management interface on a dedicated VLAN or firewall it so only trusted administrative hosts can reach the web server, and block HTTP POST and PUT from untrusted network segments; this reduces adjacent-network exposure but limits remote administration and may break legitimate configuration changes. Restrict physical and network access to the charger segment and monitor for unauthorized reboot or configuration-change requests as compensating controls. If configid is configurable, strengthen or rotate it and the service password, but that does not prevent the unauthenticated reboot and is not a substitute for a vendor fix.

Affected VersionsENISA

Delta UFC500 0 <2.4.18
Delta UFC500 0 <4.4.1

Affected Packages

euvd delta_ufc500 fix: 2.4.18, 4.4.1

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The Delta UFC500 web server performs state-changing operations through HTTP POST and PUT but does not enforce authentication on those methods, which is CWE-306 (Missing Authentication for Critical Function). The CVSS 4.0 vector describes adjacent-network access (AV:A), low attack complexity, no privileges and no user interaction, with high confidentiality and integrity impact and low availability impact; the independent CVSS 3.1 assessment agrees on adjacent access, unauthenticated exploitation and high confidentiality and integrity impact. Rebooting is directly reachable by any party able to send POST or PUT requests to the interface, while setting the service password and changing other settings is gated by the configid value that must be brute-forced according to the description. The available sources do not describe the exact request format or the length and entropy of configid.

Know when Delta Ufc500 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (DIVD) PRIMARY 8.7 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
vuln.today AI 8.3 HIGH

Adjacent-network web server with no authentication (AV:A, PR:N, AC:L); arbitrary setting/password change gives C:H/I:H, while reboot is a partial availability impact (A:L).

3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N

Primary rating from Vendor (DIVD).

CVSS VectorVendor: DIVD

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
Low
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

2
Patch available
Oct 30, 2026 - 11:02 EUVD
CVE Published
Oct 30, 2026 - 10:34 cve.org
HIGH 8.7

DescriptionCVE.org

The web server does not check authentication on POST or PUT. An unauthenticated attacker can reboot the charger; by brute-forcing the configid, they can also set the service password and then change any setting.

Executive ViewAI

Why It Matters

Delta UFC500 electric vehicle chargers contain a high-severity authentication bypass that allows attackers on the adjacent network to reboot devices and, with brute-forcing, alter critical settings including service passwords. This could disrupt charging operations and compromise configuration integrity, impacting site reliability and customer trust. Leadership should prioritize mitigation due to the potential for service outages and unauthorized control over charging infrastructure.

Business Impact: High
Compensating Controls

Network segmentation to isolate charger management interfaces, restrict adjacent network access, monitor for anomalous POST/PUT requests, and enforce strong credentials.

Threat Intelligence Overview

EPSS Score
0.2%
Top 85% exploitable
Prevalence
Low
EV charging controller, industry-specific OT device, limited enterprise footprint
Social Media
1
Sightings
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Controlled
Automatable
No
Human Impact
High
Technical Impact
Total

Priority Score

44
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy