Skip to main content

Re6250 Firmware EUVDEUVD-2025-16660

| CVE-2025-5446 MEDIUM
Command Injection (CWE-77)
2025-06-02 cna@vuldb.com
6.3
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

Full system compromise — the attacker can execute any command with the privileges of the vulnerable application process. With a CVSS score of 6.3 (MEDIUM), this represents a moderate risk.

Exploit ScenarioDerived

An attacker injects shell metacharacters (;, |, &&) into a parameter that is passed to a system command, causing additional commands to be executed.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 1.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 14, 2026

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Earlier versions of this analysis (1)
v1 Mar 14, 2026 - 16:47 CVSS 6.3

RemediationAI

Avoid passing user input to system commands. Use language-specific APIs instead of shell commands. If unavoidable, use strict input validation and escaping.

Affected VersionsENISA

RE9000 1.0.04.002
RE6500 1.0.04.002
RE6300 1.0.04.002
RE6300 1.1.05.003
RE9000 1.1.05.003
RE6250 1.2.07.001
RE9000 1.0.04.001
RE6350 1.0.04.002
RE6300 1.2.07.001
RE7000 1.0.04.001
RE7000 1.0.04.002
RE6350 1.1.05.003
RE7000 1.0.013.001
RE6350 1.0.04.001
RE6300 1.0.013.001
RE6500 1.0.04.001
RE6250 1.0.013.001
RE7000 1.1.05.003
RE6350 1.0.013.001
RE6250 1.1.05.003
RE7000 1.2.07.001
RE6250 1.0.04.002
RE6250 1.0.04.001
RE9000 1.2.07.001
RE6300 1.0.04.001
RE6500 1.2.07.001
RE6350 1.2.07.001
RE6500 1.1.05.003
RE9000 1.0.013.001
RE6500 1.0.013.001

Affected Packages

euvd re6250 no fix
euvd re6300 no fix
euvd re6350 no fix
euvd re6500 no fix
euvd re7000 no fix
euvd re9000 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 6 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Command injection allows an attacker to execute arbitrary OS commands on the host system through a vulnerable application that passes user input to system shells.

Know when Re6250 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 6.3 MEDIUM
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
Low
Availability
Low

Lifecycle Timeline

2
PoC Detected
Jun 25, 2025 - 17:24 vuln.today
Public exploit code
CVE Published
Jun 02, 2025 - 13:15 nvd
MEDIUM 6.3

Executive ViewAI

Why It Matters

Organizations using A vulnerability should be aware of moderate risk from CVE-2025-5446, a command injection vulnerability rated CVSS 6.3. Exploitation could allow attackers to execute code or inject malicious input. Proof-of-concept code is publicly available. Organizations should apply vendor updates when available and monitor for exploitation.

Business Impact: Low
Compensating Controls

Apply vendor patch. If patching is delayed: deploy WAF rules, restrict network access, enable logging.

Threat Intelligence Overview

EPSS Score
1.2%
Top 22% exploitable
Exploit
POC
Public exploit code exists
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC Yes
EPSS 1.2%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
Low

Priority Score

53
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +32
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2025-14134 HIGH POC
8.8 Dec 06

A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.0

CVE-2025-14136 HIGH POC
7.4 Dec 06

A stack-based buffer overflow in the Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 range extenders allows an

CVE-2025-14135 HIGH POC
7.4 Dec 06

Stack-based buffer overflow in the web management service of Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 r

CVE-2025-14133 HIGH POC
7.4 Dec 06

A stack-based buffer overflow in the Linksys RE-series WiFi range extenders (RE6250, RE6300, RE6350, RE6500, RE7000 and

CVE-2025-5447 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5438 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5445 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5444 MEDIUM POC
6.3 Jun 02

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.0

CVE-2025-5443 MEDIUM POC
6.3 Jun 02

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE900

CVE-2025-5442 MEDIUM POC
6.3 Jun 02

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and

CVE-2025-5441 MEDIUM POC
6.3 Jun 02

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.00

CVE-2025-5440 MEDIUM POC
6.3 Jun 02

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.0

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy