Skip to main content

Linksys RE Extenders CVE-2025-14133

| EUVDEUVD-2025-201546 HIGH
Buffer Overflow (CWE-119)
2025-12-06 cna@vuldb.com
7.4
CVSS 4.0 · Vendor: vuldb
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate to extender web UI
  2. Delivery
    Send oversized clientsname_0 to AP_get_wireless_clientlist_setClientsName
  3. Exploit
    Overflow stack buffer in mod_form.so
  4. Execution
    Hijack control flow / crash
  5. Impact
    Execute code or deny service on device

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires network access to the device's HTTP management interface and the ability to invoke the AP_get_wireless_clientlist_setClientsName handler in mod_form.so with a manipulated clientsname_0 parameter. The CVSS vector (PR:L) indicates low-privilege authentication to the web interface is needed, which limits fully anonymous exploitation; there is no user-interaction requirement (UI:N) and complexity is low (AC:L). Practical risk is bounded by exposure of the extender's management interface - typically LAN-facing rather than WAN-facing - and by the absence of any vendor patch, since the vendor did not respond to disclosure. Affected firmware: RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 at versions 1.0.013.001, 1.0.04.001, 1.0.04.002, 1.1.05.003, and 1.2.07.001.

Impact

This is a stack-based buffer overflow (CWE-119) in the mod_form.so CGI handler of several Linksys RE-series WiFi range extenders. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H, base 7.4) indicates a network-reachable, low-complexity attack requiring low-level authentication and yielding high confidentiality, integrity and availability impact on the device - consistent with memory-corruption leading to code execution or crash on an embedded MIPS/ARM appliance. Countervailing signals temper the raw score: EPSS is very low at 0.11% (30th percentile), the vulnerability is NOT on the CISA KEV list, and the CVSS carries E:P (Proof-of-Concept exploit maturity) rather than active exploitation. A public POC does exist (wudipjq/my_vuln GitHub write-up), so exploitability is demonstrated, but publicly available exploit code is a distinct signal from active exploitation - there is no evidence of the latter. The realistic priority is moderate: a working POC against consumer/SOHO range extenders whose vendor did not respond to disclosure (no patch), offset by low EPSS, no KEV, and the PR:L authentication gate. Note a metadata tension: NVD/CVSS assigns CWE-119 (general buffer overflow) while the description specifies a stack-based overflow, better modeled as CWE-121 - a refinement, not a contradiction.

Exploit ScenarioDerived

An attacker with low-privilege access to the range extender's web management interface sends a crafted request to the AP_get_wireless_clientlist_setClientsName function with an overlong clientsname_0 argument, overflowing a stack buffer in mod_form.so. This corrupts the stack to crash the device or achieve code execution as the web server process. A public proof-of-concept documenting the overflow is already available on GitHub.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv2 – Sep 25, 2026

A stack-based buffer overflow in the Linksys RE-series WiFi range extenders (RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 running firmware 1.0.013.001, 1.0.04.001, 1.0.04.002, 1.1.05.003 or 1.2.07.001) allows a remote attacker to corrupt memory in the device's web management service, with high impact to confidentiality, integrity and availability. The flaw resides in the AP_get_wireless_clientlist_setClientsName handler inside mod_form.so, where the clientsname_0 argument is copied without bounds checking; per the assessed CVSS 3.1 vector (AV:N/AC:L/PR:L/UI:N) exploitation requires low-privilege authentication to the HTTP management interface, and no user interaction is needed. Publicly available exploit code exists and was published alongside the disclosure, though EPSS assigns only a 0.11% (30th percentile) probability of exploitation in the next 30 days; the vendor was contacted but never responded, so no official fix has been identified.

Earlier versions of this analysis (1)
v1 Mar 15, 2026 - 17:37 CVSS 8.8

RemediationAI

No vendor-released patch has been identified at time of analysis: Linksys was contacted early but did not respond, and no fixed firmware version appears in the VULDB record (https://vuldb.com/?id.334522), the CPE data, or the EUVD entry (https://nvd.nist.gov/vuln/detail/CVE-2025-14133). Until a fix ships, treat the extenders as untrusted devices on the network. First, ensure the HTTP management interface is never reachable from the WAN and is confined to a trusted management VLAN or a firewall-restricted source range - this blocks remote (AV:N) exploitation entirely, at the cost of losing convenient remote administration. Second, replace the default administrator password with a strong, unique credential and disable any guest or secondary accounts, since the assessed PR:L vector depends on an attacker holding web-interface credentials; note this only raises the bar and does not mitigate an authenticated insider. Third, disable remote management and UPnP/port-forwarding features that could expose the web UI, and monitor the device's syslog or HTTP access logs for requests containing unusually long clientsname_0 values, which is the signature of the published PoC at https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_62/62.md. Where the extenders are not essential, decommission or replace them with supported hardware; where they remain in service, segment them so a compromise yields only a foothold in the isolated management segment rather than the production LAN. Re-check https://www.linksys.com/ and VULDB periodically for a firmware update, as absence of a patch today does not mean one will never be released.

Affected VersionsENISA

RE6300 1.0.013.001
RE9000 1.0.04.002
RE9000 1.2.07.001
RE7000 1.0.04.001
RE6500 1.1.05.003
RE6300 1.1.05.003
RE6250 1.2.07.001
RE7000 1.0.013.001
RE9000 1.0.04.001
RE6250 1.0.04.002
RE9000 1.1.05.003
RE6500 1.0.04.002
RE6300 1.0.04.001
RE6500 1.0.013.001
RE6250 1.0.013.001
RE6350 1.2.07.001
RE6250 1.0.04.001
RE6500 1.2.07.001
RE6350 1.0.04.002
RE6350 1.1.05.003
RE6300 1.0.04.002
RE9000 1.0.013.001
RE7000 1.1.05.003
RE7000 1.0.04.002
RE7000 1.2.07.001
RE6350 1.0.013.001
RE6500 1.0.04.001
RE6250 1.1.05.003
RE6350 1.0.04.001
RE6300 1.2.07.001

Affected Packages

euvd re6250 no fix
euvd re6300 no fix
euvd re6350 no fix
euvd re6500 no fix
euvd re7000 no fix
euvd re9000 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 6 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The vulnerability is a classic stack-based buffer overflow (CWE-119) in mod_form.so, a shared library that backs CGI handlers on Linksys RE-series range extenders. The affected function, AP_get_wireless_clientlist_setClientsName, takes a user-supplied HTTP parameter named clientsname_0 and copies it into a fixed-size stack buffer without validating its length. Because the handler is reachable through the device's embedded web management interface, an attacker who can send crafted HTTP requests to that interface can overwrite adjacent stack memory, potentially redirecting execution flow or crashing the management daemon. The CPE data confirms the vulnerable component ships as firmware across the RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 hardware lines at builds 1.0.013.001, 1.0.04.001, 1.0.04.002, 1.1.05.003 and 1.2.07.001, and EUVD records cross-combinations of those models and builds. The CVSS 4.0 vector supplied by the reporter rates the flaw 7.4 with PR:L and E:P, matching our independent CVSS 3.1 assessment of AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H: the attacker needs network reachability to the management interface and valid low-privilege credentials, but no user interaction and no elevated privileges. The buffer-overflow class here is memory-unsafe C in a long-lived embedded component, which historically makes reliable control-flow hijacking feasible on MIPS-based consumer routers when ASLR and stack canaries are weak or absent.

Know when Re6250 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (vuldb) PRIMARY 7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
vuln.today AI 8.8 HIGH

Network-reachable web handler (AV:N/AC:L), low-privilege auth to management UI (PR:L), no user interaction; stack overflow enabling code execution gives full C/I/A:H on the device.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (vuldb).

CVSS VectorVendor: vuldb

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

4
CVSS changed
Sep 25, 2026 - 23:22 NVD
8.8 (HIGH) 7.4 (HIGH)
PoC Detected
Dec 10, 2025 - 18:00 vuln.today
Public exploit code
CVE Published
Dec 06, 2025 - 11:15 cve.org
HIGH 7.4
CVE Published
Dec 06, 2025 - 11:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected by this vulnerability is the function AP_get_wireless_clientlist_setClientsName of the file mod_form.so. Performing manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack can be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability affects multiple Linksys range extender models with no vendor patch available. Exploitation requires no authentication and could allow attackers to gain complete control of affected devices on your network, potentially compromising connected systems and data.

Business Impact: High
Compensating Controls

Network segmentation: isolate range extenders on separate VLAN with restricted egress; disable remote management features if accessible; implement Web Application Firewall (WAF) rules to detect stack buffer overflow attack patterns targeting the mod_form.so endpoint; monitor for unusual outbound connections from extender IP addresses; consider disabling the wireless client list feature if not operationally required; disable UPnP if enabled; replace affected devices with patched alternatives from other vendors.

Threat Intelligence Overview

EPSS Score
0.1%
Top 70% exploitable
Prevalence
Medium
Popular consumer/SOHO Linksys WiFi range extenders, common in homes and small offices
Exploit
POC
Public exploit code exists
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

57
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +37
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2025-14134 HIGH POC
8.8 Dec 06

A vulnerability was determined in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.0

CVE-2025-14136 HIGH POC
7.4 Dec 06

A stack-based buffer overflow in the Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 range extenders allows an

CVE-2025-14135 HIGH POC
7.4 Dec 06

Stack-based buffer overflow in the web management service of Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 r

CVE-2025-5447 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5438 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5445 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5444 MEDIUM POC
6.3 Jun 02

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.0

CVE-2025-5443 MEDIUM POC
6.3 Jun 02

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE900

CVE-2025-5446 MEDIUM POC
6.3 Jun 02

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002

CVE-2025-5442 MEDIUM POC
6.3 Jun 02

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and

CVE-2025-5441 MEDIUM POC
6.3 Jun 02

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.00

CVE-2025-5440 MEDIUM POC
6.3 Jun 02

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.0

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy