Skip to main content

Secure Connect Gateway CVE-2026-78494

| EUVDEUVD-2026-74766 HIGH
Improper Certificate Validation (CWE-295)
2026-09-09 dell GHSA-whfw-gmw5-4743
7.4
CVSS 3.1 · Vendor: dell
Share

Severity by source

Vendor (dell) PRIMARY
7.4 HIGH
AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
vuln.today AI
7.4 HIGH

MITM network positioning requirement justifies AC:H; no auth or user interaction needed; certificate forgery impacts both confidentiality and integrity but not availability.

3.1 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
4.0 AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (dell).

CVSS VectorVendor: dell

Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
None

Lifecycle Timeline

3
Patch available
Sep 09, 2026 - 09:18 EUVD
Analysis Generated
Sep 09, 2026 - 09:08 vuln.today
CVE Published
Sep 09, 2026 - 08:07 cve.org
HIGH 7.4

DescriptionCVE.org

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Certificate Validation vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access.

AnalysisAI

Improper certificate validation in Dell Secure Connect Gateway 5.0 (both Appliance and Application variants) enables an unauthenticated remote attacker with a man-in-the-middle network position to intercept and modify encrypted communications between the SCG platform and Dell's support infrastructure. Rated CVSS 7.4 (CWE-295) with high confidentiality and integrity impact, this flaw is particularly sensitive given that SCG routinely carries privileged support telemetry and credentials. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation The attacker must establish a man-in-the-middle position on the network path between the Dell SCG instance and Dell's external support infrastructure - this is the principal limiting constraint reflected in CVSS AC:H, and excludes purely passive or remote attackers lacking network positioning. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 7.4 vector (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N) accurately characterizes the threat profile: network-reachable and requiring no authentication or user interaction, but constrained by the need for attacker-controlled network positioning (AC:H). … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Vendor-released patch: upgrade Dell SCG 5.0 Appliance to version 5.36.00.16 or later and Dell SCG 5.0 Application to version 5.36.00.00 or later per Dell advisory DSA-2026-382 (https://www.dell.com/support/kbdoc/en-in/000503426/dsa-2026-382-security-update-for-dell-secure-connect-gateway-virtual-edition-multiple-vulnerabilities). … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, identify and inventory all Dell SCG 5.0 instances in your environment (both Appliance and Application variants) and assess which are exposed to potential man-in-the-middle attack positions. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

CVE-2026-80131 CRITICAL
9.8 Sep 07

Remote code execution in Dell Secure Connect Gateway (SCG) 5.0 allows an unauthenticated remote attacker to escape the i

CVE-2026-80172 CRITICAL
9.8 Sep 09

Unauthorized ADMIN access in Dell Secure Connect Gateway (SCG) 5.0 allows a remote unauthenticated attacker to replay a

CVE-2026-61410 CRITICAL
9.4 Sep 07

Remote command execution in Dell Secure Connect Gateway 5.0 (Appliance versions before 5.36.00.16 and Application versio

CVE-2026-80164 CRITICAL
9.1 Sep 07

Unauthorized remote access to Dell Secure Connect Gateway (SCG) 5.0 is possible because the product fails to properly va

CVE-2026-80130 HIGH
8.8 Sep 07

Relative path traversal in Dell Secure Connect Gateway (SCG) 5.0 allows a low-privileged remote attacker to traverse dir

CVE-2026-79645 HIGH
8.2 Sep 07

Missing authentication on critical API functions in Dell Secure Connect Gateway (SCG) 5.0 exposes privileged operations

CVE-2026-78491 HIGH
8.2 Sep 09

Improper certificate validation in Dell Secure Connect Gateway (SCG) 5.0 allows remote unauthenticated attackers to expl

CVE-2026-80133 HIGH
8.1 Sep 07

Relative path traversal in Dell Secure Connect Gateway 5.0 (both Appliance and Application editions) exposes unauthentic

CVE-2026-80132 HIGH
8.1 Sep 07

Dell Secure Connect Gateway (SCG) 5.0 exposes a critical management function without any authentication requirement (CWE

CVE-2026-78484 HIGH
7.8 Sep 09

OS command injection in Dell Secure Connect Gateway (SCG) 5.0 enables a locally authenticated low-privilege attacker to

CVE-2026-78493 HIGH
7.8 Sep 09

OS command injection in Dell Secure Connect Gateway (SCG) 5.0 - both Appliance (prior to 5.36.00.16) and Application (pr

CVE-2026-80178 HIGH
7.8 Sep 07

Local privilege escalation in Dell Secure Connect Gateway 5.0 enables a low-privileged authenticated user with local she

Share

CVE-2026-78494 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy