Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain admin access to UniFi OS Server
-
DeliveryReach management interface over network
-
ExploitSubmit crafted input to vulnerable function
-
ExecutionInjected input bypasses input validation
-
PersistExecute arbitrary OS commands on host
-
ImpactFull host compromise
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V2 - Validation and Business Logic Input validation, allowlisting
|
| Exploitation Conditions | Exploitation requires the attacker to already hold high-privilege (administrative) access to the UniFi OS Server (CVSS PR:H) and network reachability to its management interface (AV:N); no user interaction is needed (UI:N) and attack complexity is low (AC:L). The limiting factor is therefore authentication and authorization: this is not exploitable by an unauthenticated or low-privileged attacker, so it functions as a host-breakout/privilege-boundary bypass usable by a legitimate-but-malicious admin or by an attacker who has previously compromised admin credentials. Segmenting or restricting who can reach the management plane and who holds admin rights directly gates realistic exploitation. |
| Impact | The signals are mixed. CVSS is 9.1 (Critical) driven by network vector (AV:N), low complexity (AC:L), no user interaction (UI:N), scope change (S:C), and full C/I/A impact - but the PR:H requirement is the decisive limiter: an attacker must already hold high-privilege (administrative) access to the UniFi OS Server before this becomes exploitable. That downgrades it from a pre-auth internet worm risk to a privilege-escalation / host-takeover primitive useful to an insider or to an attacker who has already compromised admin credentials. There is no CISA KEV listing and no public POC referenced, and EPSS was not provided, so there is no evidence of active or widespread exploitation; the practical priority hinges on how exposed and how well-segmented each operator's management plane is, and a mid-sized municipal IT team in radom running an internet-reachable UniFi OS Server with shared admin credentials should still patch promptly. Net: treat as a high-priority patch for any deployment where admin access is broadly held or the management interface is exposed, but not an emergency drop-everything issue for well-segmented, tightly-administered installations. |
| Exploit ScenarioDerived | An attacker who has obtained high-privilege administrative access to a UniFi OS Server - for example via reused or phished admin credentials, or a malicious insider - submits crafted input to a management function that is passed unsanitized into a host command, injecting attacker-controlled OS commands. Because the process can act on the host, the injected command runs with host-service privileges, giving the attacker code execution and full control of the device. No public POC is referenced, and low attack complexity (AC:L) means exploitation is straightforward once the privilege prerequisite is met. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Aug 26, 2026
Command injection in Ubiquiti UniFi OS Server allows an attacker holding high-privilege access and network reachability to execute arbitrary operating-system commands on the underlying host, per Ubiquiti Security Advisory Bulletin 067. The flaw stems from improper input validation (CWE-20) and, with a scope-changed CVSS 9.1, lets a compromised or malicious privileged account break out of the application context to fully control the host. No public exploit identified at time of analysis, and it is not listed in CISA KEV.
RemediationAI
Patch available per vendor advisory - update UniFi OS Server to the fixed release identified in Ubiquiti Security Advisory Bulletin 067 (https://community.ui.com/releases/Security-Advisory-Bulletin-067/fc4a3488-7c43-4628-8bab-f715e96dbfc9); the exact patched version is not stated in the available data, so verify the target build directly in that advisory. Until patched, reduce the exploitation surface by restricting network access to the UniFi OS Server management interface to a dedicated administrative VLAN or VPN (trade-off: remote admins must connect through the jump path), and tighten the high-privilege account population - enforce unique strong credentials and MFA for all admin accounts and remove shared or unused admin logins (trade-off: operational overhead), since the vulnerability requires PR:H and thus depends on an attacker obtaining admin-level access. Do not expose the management console directly to the internet.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
UniFi OS Server is Ubiquiti's self-hosted management platform (the software distribution of UniFi OS that runs network, protect, and related controller applications on customer-provided hardware/VMs), identified by the CPE cpe:2.3:a:ubiquiti_inc:unifi_os_server. The root cause is CWE-20 Improper Input Validation: attacker-controlled input reaching a management function is not adequately sanitized before being used in an OS command context, enabling Command Injection. Because the vulnerable process can invoke shell/host commands, successful injection escapes the application boundary - reflected in the CVSS scope change (S:C) - and runs with the privileges of the host service.
Know when Unifi Os Server gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Requires pre-existing admin access (PR:H) and network reach (AV:N); command injection escapes app to host (S:C) yielding full host C/I/A impact.
Primary rating from Vendor (Ubiquiti).
CVSS VectorVendor: Ubiquiti
Lifecycle Timeline
2DescriptionCVE.org
A malicious actor with access to the network and high privileges could exploit an Improper Input Validation vulnerability found in UniFi OS Server to execute a Command Injection on the host device.
Executive ViewAI
A critical command injection vulnerability in Ubiquiti UniFi OS Server (CVSS 9.1) allows compromised or malicious administrators to execute arbitrary commands and gain complete control of the underlying host. Since UniFi servers typically manage critical network infrastructure, a breach could enable an attacker to disrupt, redirect, or compromise all network traffic and connected devices. Organizations must immediately audit administrative access and implement protective controls while awaiting a vendor patch.
No vendor-released patch identified at time of analysis. Interim mitigations include: (1) enforce principle of least privilege on UniFi administrator accounts; (2) implement network segmentation to isolate UniFi servers from general network traffic; (3) enable comprehensive admin activity logging and real-time alerting on authentication and command execution; (4) require multi-factor authentication for all administrative access; (5) conduct regular backups of UniFi configurations to enable rapid recovery; (6) monitor for suspicious process execution and network connections originating from UniFi server processes.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
More in Unifi Os Server
View allUnauthenticated command injection in Ubiquiti UniFi OS devices allows remote attackers with network access to execute ar
Path traversal in Ubiquiti UniFi OS devices allows network-adjacent attackers to read sensitive files from the underlyin
Unauthorized system modification on Ubiquiti UniFi OS devices allows network-adjacent attackers to alter device configur
Authentication bypass in Ubiquiti UniFi OS lets a network-adjacent, unauthenticated attacker abuse improper neutralizati
Privilege escalation in Ubiquiti UniFi OS lets a low-privileged actor with network access to an affected device elevate
Privilege escalation in Ubiquiti UniFi OS devices allows a network-adjacent attacker holding a low-privileged account to
Authenticated command injection in Ubiquiti UniFi OS allows low-privileged network-adjacent attackers to execute arbitra
Privilege escalation in Ubiquiti UniFi OS allows a low-privileged attacker with network access to elevate privileges on
Command injection in Ubiquiti UniFi OS Server allows an attacker holding high-privilege (administrative) access on the n
Command injection in Ubiquiti UniFi OS devices allows a high-privileged attacker on the network to execute arbitrary ope
Authentication bypass in Ubiquiti UniFi OS lets a network-adjacent attacker circumvent login on affected devices by inje
Privilege escalation in Ubiquiti UniFi OS affects a broad range of gateway, NVR, storage, and Cloud Key appliances runni
EUVD-2026-66367
GHSA-w5vh-8c24-45f5
NVD
CVE.org
EPSS
Vulnrichment
VulDB
Exploit-DB