Advantech EKI-1242EIMS CVE-2026-73175

| EUVDEUVD-2026-80724 HIGH
Uncontrolled Resource Consumption (CWE-400)
2026-09-16 Nozomi GHSA-mvv7-vr4g-xvmv
7.1
CVSS 4.0 · Vendor: Nozomi
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain adjacent network foothold
  2. Delivery
    Reach OPC UA gateway endpoint
  3. Exploit
    Open many anonymous sessions
  4. Execution
    Exhaust server session pool
  5. Impact
    Legitimate OPC UA clients denied service

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V2 - Validation and Business Logic Resource consumption limits
MITRE ATT&CK

1 technique across 1 tactic: Impact

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires the OPC UA gateway component to be enabled and reachable, and the OPC UA server must permit anonymous sessions (the description explicitly states the attacker opens 'multiple anonymous sessions'). The attacker must be on an adjacent network segment (AV:A) - Layer 2 or logically adjacent to the device - not routed remotely across the internet. No authentication, credentials, or user interaction are needed. Limiting factors: adjacency requirement (attacker needs an existing network foothold), and impact is confined to availability of OPC UA service - no data is read or modified, and other device functions are unaffected. Deployments that disable anonymous OPC UA access or segment the OT network tightly reduce exposure.

Impact

This is a genuine but bounded availability risk. The CVSS 4.0 vector (AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H, score 7.1) is well-calibrated and internally consistent with the description: adjacency (AV:A) means the attacker must be on the same L2/adjacent network segment rather than routing from the internet, complexity is low, no privileges or user interaction are needed, and impact is purely availability (VA:H) with zero confidentiality or integrity effect - appropriate for a session-pool exhaustion DoS. There is NO conflict between the vector and the description. Real-world urgency is tempered by the absence of exploitation signals: no CISA KEV listing, no public POC, and no EPSS score is provided in the input. The adjacency requirement is a meaningful limiter - an attacker needs a foothold on the OT/local network, which is the norm for ICS threat models but excludes opportunistic internet-wide scanning. Net: a real, easy-to-trigger availability issue against a niche OT device that matters most where OPC UA continuity is operationally critical, but not a mass-exploitation priority. Note the input omits EPSS/KEV/POC entirely - treat exploitation likelihood as unquantified rather than confirmed-low.

Exploit ScenarioDerived

An attacker with a foothold on the same industrial/adjacent network segment as an EKI-1242EIMS gateway repeatedly opens anonymous OPC UA sessions until the server's session pool is fully consumed. Once exhausted, all legitimate OPC UA clients (SCADA/HMI, historians, PLC integrations) are refused new sessions, causing a complete denial of service to the gateway's OPC UA function. No authentication, credentials, or user interaction are required; no public exploit code has been identified at time of analysis.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Sep 16, 2026

Session pool exhaustion in the OPC UA gateway of Advantech EKI-1242EIMS and EKI-1242IEIMS industrial switches running firmware V1.06.01 lets an unauthenticated attacker on an adjacent network segment open multiple anonymous OPC UA sessions and consume the entire server session pool, causing a complete denial of service for all legitimate OPC UA clients. The impact is availability-only (no data read or modified, other device functions unaffected) and is bounded by the adjacency requirement plus the need for the OPC UA gateway to be enabled and to accept anonymous sessions, matching the reported CVSS 7.1 (CVSS 4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H) and the independently assessed CVSS 3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. There is no CISA KEV listing and no public exploit identified at time of analysis; the finding is credited to Nozomi Networks Labs.

RemediationAI

Patch available per vendor advisory: apply the firmware fix documented in Advantech's security advisory for EKI-1242IEIMS (and the corresponding EKI-1242EIMS release); the provided data does not name an exact fixed version, so confirm the target build against the advisory at https://advcloudfiles.advantech.com/cms/5dafee28-ad53-4d07-a328-7896fcc24b6e/Security%20Advisory%20PDF%20File/SECURITY-ADVISORY----EKI-1242IEIMS-updated-20260904.pdf before upgrading, and plan for a service-affecting reboot in a maintenance window. If upgrading cannot be done immediately, the most effective compensating control is to disable anonymous OPC UA access and require an authenticated security policy with user tokens or client certificates - the trade-off being that every OPC UA client must be re-provisioned with credentials or certificates and misconfiguration will break the SCADA/engineering connection. If the OPC UA gateway is not in use, disable that component outright. Additionally, restrict TCP 4840 (the default OPC UA port) to an explicit allowlist of trusted engineering and SCADA hosts using switch ACLs and upstream Layer 3 rules - recognizing that an attacker with an adjacent Layer 2 foothold and a spoofed or reused address may still reach the port, and that legitimate clients on other subnets must be added explicitly. Because exploitation requires Layer 2 adjacency, harden OT segmentation with VLAN separation, 802.1X/NAC on access ports, and disabling unused switch ports, and monitor the gateway for abnormal counts of concurrent anonymous sessions or repeated session establishment from a single host as an early warning indicator; refer to the Nozomi Networks Labs advisory at https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2026-73175 for any further vendor guidance.

Affected VersionsENISA

EKI-1242IEIMS 0 ≤1.06.01
EKI-1242EIMS 0 ≤1.06.01

Affected Packages

euvd eki_1242eims no fix
euvd eki_1242ieims no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 2 packages in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected platforms are Advantech EKI-1242EIMS and EKI-1242IEIMS industrial managed Ethernet switches whose OPC UA gateway exposes an OPC UA server (IEC 62541) to SCADA/OT clients, matching the CPEs cpe:2.3:a:advantech:eki-1242eims and cpe:2.3:a:advantech:eki-1242ieims (both version-wildcarded, so version confirmation must come from the vendor advisory; the description pins the affected firmware to V1.06.01). The root cause is CWE-400, Uncontrolled Resource Consumption: the gateway's session handling allows unbounded establishment of anonymous sessions and does not cap, rate-limit, or promptly reap unauthenticated sessions, so each new anonymous session holds a slot in a finite server-side session pool until it is exhausted. OPC UA anonymous sessions are established without a user token, credential, or client certificate, so no authentication barrier stands between the attacker and the resource being consumed - consistent with the PR:N and UI:N components of the scoring vectors. The consequence is confined to the OPC UA service itself (VC:N/VI:N/VA:H with no subsequent-system impact), and the AT:N/AV:A values indicate no special attack conditions beyond being an adjacent-segment host able to reach the enabled gateway.

Know when Eki 1242Ieims gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (Nozomi) PRIMARY 7.1 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
vuln.today AI 6.5 MEDIUM

Adjacent unauthenticated session flood with low complexity and no interaction; impact is purely availability (session-pool exhaustion), so C:N/I:N/A:H and S:U.

3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (Nozomi).

CVSS VectorVendor: Nozomi

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
None
Vulnerable system: Integrity
None
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

Nozomi Networks Labs identified a CWE-400: Uncontrolled Resource Consumption vulnerability in the OPC UA gateway component of Advantech EKI-1242EIMS in firmware version V1.06.01 that allows an adjacent unauthenticated attacker to exhaust the server session pool and cause a complete denial of service to all legitimate OPC UA clients by opening multiple anonymous sessions.

Executive ViewAI

Why It Matters

Advantech EKI-1242EIMS and EKI-1242IEIMS industrial switches running firmware V1.06.01 can be knocked offline at the OPC UA gateway layer, cutting off every legitimate OPC UA client that depends on those switches for OT data collection and control traffic. The attacker needs only a foothold on an adjacent network segment and no credentials; no vendor patch is currently available, so exposure persists until mitigations are applied or devices are updated. Leadership should care because these switches typically sit at the boundary of industrial control networks, making the outage an operational-visibility problem for plant and SCADA teams rather than a data-breach problem.

Business Impact: Medium
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: disable the OPC UA gateway on firmware V1.06.01 devices where it is not operationally required; disable anonymous OPC UA session acceptance and require authenticated sessions; enforce firewall or ACL rules on the adjacent network segment so only known OPC UA clients can reach the gateway; apply session and connection rate limiting; monitor and alert on session-pool exhaustion or abnormal volumes of anonymous sessions.

Threat Intelligence Overview

EPSS Score
0.2%
Top 86% exploitable
Prevalence
Low
niche industrial OPC UA/Modbus-EtherNet-IP gateway, OT-only deployment footprint
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
Medium

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

CVE-2026-73172 CRITICAL
9.3 Sep 16

Unauthenticated OS command injection in the edgserver management service of Advantech EKI-1242EIMS and EKI-1242IEIMS gat

CVE-2026-73173 HIGH
8.8 Sep 16

Advantech EKI-1242EIMS and EKI-1242IEIMS industrial gateways running firmware V1.06.01 expose their edgserver management

CVE-2026-73176 HIGH
8.6 Sep 16

Authenticated OS command injection in the web management interface of Advantech EKI-1242IEIMS and EKI-1242EIMS industria

CVE-2026-73167 HIGH
8.6 Sep 16

OS command injection in the web management interface of the Advantech EKI-1242IEIMS and EKI-1242EIMS industrial gateways

CVE-2026-73165 HIGH
8.6 Sep 16

OS command injection in the web management interface of Advantech EKI-1242IEIMS and EKI-1242EIMS industrial devices runn

CVE-2026-73164 HIGH
8.6 Sep 16

Authenticated high-privileged users of Advantech EKI-1242IEIMS and EKI-1242EIMS industrial gateways running firmware V1.

CVE-2026-73163 HIGH
8.6 Sep 16

OS command injection in the web management interface of Advantech EKI-1242IEIMS industrial gateways (firmware V1.06.01)

CVE-2026-73166 HIGH
8.6 Sep 16

Code injection in the web management interface of Advantech EKI-1242IEIMS (and the closely related EKI-1242EIMS) industr

CVE-2026-73174 HIGH
8.7 Sep 16

Passive interception of the cleartext edgserver management protocol on Advantech EKI-1242EIMS and EKI-1242IEIMS devices

CVE-2026-73170 HIGH
8.6 Sep 16

Arbitrary Lua code execution is possible on Advantech EKI-1242EIMS and EKI-1242IEIMS industrial Modbus gateways running

CVE-2026-73171 HIGH
8.6 Sep 16

An authenticated file-overwrite vulnerability in the backup-restore workflow of Advantech EKI-1242EIMS (and EKI-1242IEIM

CVE-2026-19535 HIGH
8.6 Sep 16

Cross-site request forgery in the LuCI administrative web interface of Advantech EKI-1242IEIMS running firmware V1.06.01

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy