Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Internal vessel network requirement makes AV:A more accurate than AV:N; no authentication needed (PR:N); only configuration integrity impact is described, so C:N and A:N.
Primary rating from Vendor (jpcert).
CVSS VectorVendor: jpcert
Lifecycle Timeline
3DescriptionCVE.org
FA-50 all versions miss authentication for some configuration. An attacker with access to the vessel's internal network can manipulate the product's settings screen to alter some configuration parameters.
AnalysisAI
Configuration manipulation in the Furuno FA-50 maritime device (all versions) is possible without authentication from the vessel's internal network. The product fails to enforce access controls on its settings interface (CWE-306), allowing any attacker who gains internal network access to alter device configuration parameters. …
Unlock full vulnerability intelligence
- Risk assessment & exploitation conditions
- Attack chain visualization
- Remediation with exact patch versions
- Threat intelligence from 22 sources
- Personal watchlist & email alerts
Free forever · No credit card required
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata
Vulnerability AssessmentAI
| Exploitation | Exploitation requires network connectivity to the vessel's internal LAN where the FA-50 is deployed - the attacker cannot exploit this remotely over the public internet without first traversing the vessel's network perimeter. … Additional conditions and limiting factors are described in the full assessment. |
| Risk Assessment | The CVSS 4.0 score of 8.7 reflects a network-accessible (AV:N), low-complexity, no-authentication-required exploit path with high integrity impact. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in. |
| Exploit Scenario | Full exploit scenario with step-by-step reproduction available after sign-in. |
| Remediation | Consult the Furuno vendor advisory at https://www.furuno.co.jp/en/news/notice/notice_category.html?itemid=1857&dispmid=965 for firmware update guidance; no specific fixed version number was provided in the available intelligence data, so patch availability and exact update version must be confirmed directly with Furuno Electric. … Detailed patch versions, workarounds, and compensating controls in full report. |
Recommended ActionAI
Within 24 hours: Identify and inventory all Furuno FA-50 devices across the fleet and document their network locations. …
Sign in for detailed remediation steps and compensating controls.
Threat intelligence, references, and detailed analysis are available after sign-in.
Same technique Authentication Bypass
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-65318