Skip to main content

Advantech ADAM-3600 CVE-2026-43836

| EUVDEUVD-2026-104831 CRITICAL
Command Injection (CWE-77)
2026-10-20 CSA GHSA-7wv5-vcx2-7h34
9.3
CVSS 4.0 · Vendor: CSA
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach RTU network/management interface
  2. Delivery
    Send forged crafted protocol packet
  3. Exploit
    Trigger command-execution flaw in service
  4. Execution
    Execute arbitrary OS commands at max privilege
  5. Impact
    Full device compromise and OT process disruption

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires network reachability to the ADAM-3600's vulnerable packet-processing service; per PR:N/UI:N/AC:L, no authentication, no user interaction, and no special non-default configuration are indicated, so default-configured devices are exploitable by sending a single forged packet. The primary LIMITING factor is network exposure: ADAM-3600 RTUs are typically deployed on segmented OT/SCADA networks, so real-world reachability depends on the device being internet-exposed or accessible from a compromised IT/DMZ segment. The exact vulnerable protocol/port and affected firmware versions are not specified in the available data, which limits precise detection/scoping.

Impact

This is a genuinely high-priority flaw, not a high-CVSS-but-low-real-risk case. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N with VC:H/VI:H/VA:H) describes unauthenticated, network-reachable, low-complexity remote code execution with full confidentiality, integrity, and availability impact - the maximum practical exposure profile, consistent with the description's 'forge a packet to execute arbitrary commands with maximum privileges.' However, several key exploitation signals are MISSING from the input and must not be assumed: no EPSS score was provided (exploitation probability unknown), the CVE is NOT listed in CISA KEV in the supplied data (no confirmed active exploitation), and no POC/exploit-code indicator was provided (no public exploit identified). So while the intrinsic severity is critical, there is currently NO evidence of in-the-wild exploitation or available weaponized code. The affected product, Advantech ADAM-3600, is an industrial RTU/IIoT controller used in SCADA/OT environments; compromise means operator-privilege command execution on a field control device, which carries disproportionately high operational/safety consequences in the environments where it IS deployed, even though its overall internet footprint is small. Net: treat as a top-tier patch priority for any OT environment running ADAM-3600, while recognizing exploitation-likelihood telemetry (EPSS/KEV/POC) is absent rather than reassuringly low.

Exploit ScenarioDerived

An attacker with network reachability to an exposed ADAM-3600 RTU sends a single forged/crafted protocol packet to the vulnerable service, which processes it and executes attacker-supplied commands at maximum (operator/root-equivalent) privilege without any authentication or user interaction. No public exploit code was identified at time of analysis, but the AV:N/AC:L/PR:N/UI:N profile means a working exploit would be straightforward to develop and reuse. Successful exploitation yields full control of the industrial controller and the ability to manipulate monitored/controlled OT processes.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.6% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 20, 2026

Forged network packets sent to the Advantech ADAM-3600 remote terminal unit (RTU) can trigger arbitrary command execution at maximum (administrative/root) privilege, giving an unauthenticated remote attacker full control of the device. The flaw is rated 9.3 under CVSS 4.0 and corroborated by an independent assessment of CVSS 3.1 AV:N/AC:L/PR:N/UI:N/C:H/I:H/A:H - no authentication, no user interaction, and no non-default configuration are required, so a single crafted packet against a default-configured unit is sufficient. Exploitation is bounded mainly by network reachability: these RTUs normally sit on segmented OT/SCADA networks, but any unit exposed to the internet or reachable from a compromised IT/DMZ segment is directly at risk. No public exploit code or CISA KEV entry was identified at time of analysis, and no EPSS score was supplied; CSA Singapore (AL-2026-149) and Advantech have published advisories. This is a genuinely high-priority flaw, not a high-CVSS-but-low-real-risk case.

RemediationAI

No vendor-released patch version is identified in the available data - absence of data is not confirmation that no fix exists - so the first action is to pull the current firmware and fixed-build list from Advantech's security advisory (https://www.advantech.com/en/security-advisory) and cross-check it against CSA Singapore AL-2026-149 (https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-149), then upgrade every ADAM-3600 to the vendor-designated fixed firmware as soon as an OT change window permits, budgeting for a device restart and brief loss of telemetry. Because exploitation needs only one unauthenticated forged packet, treat network isolation as the primary compensating control until firmware is applied: deny all inbound traffic to the RTU from corporate, DMZ and internet paths at the OT firewall or conduit, allowing only the specific engineering workstations and SCADA masters that legitimately poll it - the trade-off is that broad 'any' rules currently used for vendor support or remote diagnostics must be replaced with named-host allowlists, which will break ad-hoc access and requires asset inventory to be accurate beforehand. Remove any direct internet exposure (NAT/port-forward) of the device and route remote maintenance exclusively through a VPN or jump host with MFA, accepting the added latency and session-management overhead. On the device itself, disable unused services and protocols and change default credentials where the firmware allows, though these are hardening steps and do not remediate the packet-forging flaw. Finally, enable logging/IDS coverage for anomalous traffic to the RTU's service ports so that forged-packet attempts and unexpected command activity are detectable, noting that many ADAM-3600 deployments lack native flow logging and may require a span/mirror port on the OT switch.

Affected VersionsENISA

ADAM-3600 prior to version 2.8.5.0

Affected Packages

euvd adam_3600_prior_to_version no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The ADAM-3600 is an industrial remote terminal unit / intelligent I/O controller used in SCADA and telemetry deployments, running an embedded firmware stack that listens on the network for configuration, telemetry and management traffic. The vulnerability lies in the parsing of that inbound packet traffic: the device accepts forged packets without adequately verifying their origin or integrity, and the result of that trust failure is arbitrary command execution at the highest privilege level on the device. No CWE identifier was assigned in the source data, but the described behavior is consistent with the missing-authentication-for-critical-function (CWE-306) and improper-verification-of-authenticity (CWE-345) classes - an inference, not a vendor-confirmed classification. The CVSS 4.0 vector (AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H) and the independently assessed CVSS 3.1 vector agree that the attack surface is remote, unauthenticated and requires no user action, and the absence of AT:P/AC:H modifiers indicates no race condition or special preconditions. Notably, the supplied tags mention 'Information Disclosure', which understates the described impact; the authoritative description and both vectors point to command execution with confidentiality, integrity and availability all rated High, and that more severe characterization should drive prioritization. The precise vulnerable protocol, port and firmware build range are not disclosed in the available data, which limits fingerprint-based scoping and detection.

Know when Adam 3600 gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (CSA) PRIMARY 9.3 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 9.8 CRITICAL

Forged packet gives unauthenticated network RCE with no user interaction (AV:N/AC:L/PR:N/UI:N) and max-privilege command execution yields full C/I/A impact; scope unchanged as impact stays on the device.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (CSA).

CVSS VectorVendor: CSA

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability could allow an attacker to forge a packet to execute arbitrary commands with maximum privileges.

Executive ViewAI

Why It Matters

Advantech ADAM-3600 remote terminal units are exposed to a critical unauthenticated remote command-execution flaw that can give an attacker administrative/root control of the device with a single forged network packet. This threatens OT/SCADA process integrity, availability, and safety wherever ADAM-3600 units are reachable from untrusted networks, especially internet-facing or flat IT/DMZ-adjacent deployments. Leadership should care because the flaw is critical, no vendor-released patch was identified at time of analysis, and exposure reduction must proceed immediately even though no public exploit was identified at time of analysis.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis; interim mitigations are network segmentation and deny-by-default ACLs around ADAM-3600, blocking internet and IT/DMZ reachability, restricting protocols and management to trusted OT hosts, deploying IDS/IPS monitoring, and rapidly isolating exposed units.

Threat Intelligence Overview

EPSS Score
0.6%
Top 52% exploitable
Prevalence
Low
industrial SCADA/RTU device, niche OT-specific deployment footprint
Threat Intel
1
1 source
Social Media
1
Sightings
Data Quality
6 sources
Confidence: High

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.6%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Scheduled
Exploitation
None
System Exposure· derived
Open
Automatable
Yes
Human Impact
High
Technical Impact
Total

Priority Score

47
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +46
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-43844 CRITICAL
9.3 Oct 20

Authentication bypass in Advantech ADAM-3600 remote terminal units allows unauthenticated network attackers to bypass th

CVE-2026-43845 CRITICAL
9.2 Oct 20

Authentication bypass in Advantech ADAM-3600 enables unauthenticated network attackers to abuse the password-reset mecha

CVE-2026-43838 CRITICAL
9.2 Oct 20

Unauthenticated remote code execution is possible against the Advantech ADAM-3600 through a stack-based buffer overflow

CVE-2026-43850 HIGH
8.6 Oct 20

Authenticated, high-privilege users of the Advantech ADAM-3600 industrial edge gateway can exploit a command injection f

CVE-2026-43839 HIGH
8.7 Oct 20

Unauthenticated remote attackers can crash the logs management service on Advantech ADAM-3600 industrial RTUs/controller

CVE-2026-43858 HIGH
8.6 Oct 20

Stack-based buffer overflow in Advantech ADAM-3600 can let a remote attacker with administrative credentials execute arb

CVE-2026-43856 HIGH
8.6 Oct 20

Stack-based buffer overflow in Advantech ADAM-3600's FileProcess::CheckDir path handling lets an authenticated attacker

CVE-2026-43857 HIGH
8.6 Oct 20

Arbitrary code execution on Advantech ADAM-3600 devices is possible for remote attackers who already possess high-privil

CVE-2026-43846 HIGH
8.6 Oct 20

Stack-based buffer overflow in Advantech ADAM-3600 industrial remote I/O modules lets a high-privileged authenticated at

CVE-2026-43835 HIGH
8.6 Oct 20

A privileged, authenticated attacker who can reach the Advantech ADAM-3600 firmware upgrade function can upload a forged

CVE-2026-43853 HIGH
8.2 Oct 20

The Advantech ADAM-3600 industrial RTU/edge controller can be crashed by a remotely delivered crafted message that trigg

CVE-2026-43852 HIGH
8.2 Oct 20

Arbitrary file write in Advantech ADAM-3600 lets an authenticated attacker with high-privilege operator or administrator

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy