Skip to main content

Linux CVE-2026-31550

| EUVDEUVD-2026-25443 MEDIUM
2026-04-24 Linux GHSA-jccg-jh56-vh7j
5.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
5.5 MEDIUM
AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
SUSE
MEDIUM
qualitative
Red Hat
5.5 LOW
qualitative

Primary rating from NVD.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

5
CVSS changed
Apr 27, 2026 - 20:22 NVD
5.5 (MEDIUM)
Patch released
Apr 27, 2026 - 20:15 nvd
Patch available
Patch available
Apr 24, 2026 - 16:01 EUVD
EUVD ID Assigned
Apr 24, 2026 - 15:00 euvd
EUVD-2026-25443
CVE Published
Apr 24, 2026 - 14:33 nvd
MEDIUM 5.5

DescriptionCVE.org

In the Linux kernel, the following vulnerability has been resolved:

pmdomain: bcm: bcm2835-power: Increase ASB control timeout

The bcm2835_asb_control() function uses a tight polling loop to wait for the ASB bridge to acknowledge a request. During intensive workloads, this handshake intermittently fails for V3D's master ASB on BCM2711, resulting in "Failed to disable ASB master for v3d" errors during runtime PM suspend. As a consequence, the failed power-off leaves V3D in a broken state, leading to bus faults or system hangs on later accesses.

As the timeout is insufficient in some scenarios, increase the polling timeout from 1us to 5us, which is still negligible in the context of a power domain transition. Also, replace the open-coded ktime_get_ns()/ cpu_relax() polling loop with readl_poll_timeout_atomic().

Analysis

In the Linux kernel, the following vulnerability has been resolved:

pmdomain: bcm: bcm2835-power: Increase ASB control timeout

The bcm2835_asb_control() function uses a tight polling loop to wait for the ASB bridge to acknowledge a request. During intensive workloads, this handshake intermittently fails for V3D's master ASB on BCM2711, resulting in "Failed to disable ASB master for v3d" errors during runtime PM suspend. As a consequence, the failed power-off leaves V3D in a broken state, leading to bus faults or system hangs on later accesses.

As the timeout is insufficient in some scenarios, increase the polling timeout from 1us to 5us, which is still negligible in the context of a power domain transition. Also, replace the open-coded ktime_get_ns()/ cpu_relax() polling loop with readl_poll_timeout_atomic().

Vendor StatusVendor

SUSE

Severity: Medium
Product Status
SUSE Linux Enterprise Desktop 15 SP7 Fixed
SUSE Linux Enterprise Desktop 15 SP7 Fixed
SUSE Linux Enterprise High Availability Extension 15 SP7 Fixed
SUSE Linux Enterprise High Availability Extension 15 SP7 Fixed
SUSE Linux Enterprise High Performance Computing 15 SP7 Fixed