Skip to main content

Tenable Security Center CVE-2026-19639

| EUVDEUVD-2026-58738 MEDIUM
Improper Validation of Specified Quantity in Input (CWE-1284)
2026-08-14 tenable GHSA-f5m5-34r9-8764
5.3
CVSS 4.0 · Vendor: tenable
Share

Severity by source

Vendor (tenable) PRIMARY
5.3 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
4.3 MEDIUM

Authenticated non-admin access required (PR:L); read-only settings disclosure yields C:L; no integrity, availability, or scope-change impact confirmed.

3.1 AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (tenable).

CVSS VectorVendor: tenable

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

3
Patch available
Aug 14, 2026 - 19:01 EUVD
Analysis Generated
Aug 14, 2026 - 18:24 vuln.today
CVSS changed
Aug 14, 2026 - 18:22 NVD
4.3 (MEDIUM) 5.3 (MEDIUM)

DescriptionCVE.org

An improper access control vulnerability exists where an authenticated non-administrative application user could potentially view settings outside of their assigned scope.

AnalysisAI

Improper access control in Tenable Security Center enables authenticated non-administrative users to read application settings that fall outside their assigned organizational or role-based scope, constituting an unauthorized information disclosure. The vulnerability requires only a low-privileged authenticated account and is exploitable over a network with no user interaction or special triggering conditions, per the CVSS 4.0 vector (AV:N/AC:L/PR:L). …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
Obtain non-admin Security Center credentials
Exploit
Authenticate over network to SC web interface
Execution
Request out-of-scope settings resources
Impact
Read unauthorized configuration data

Vulnerability AssessmentAI

Exploitation Exploitation requires an authenticated, non-administrative user account on the Tenable Security Center application - unauthenticated or anonymous access is not sufficient, and administrative accounts are out of scope since they already have broader visibility. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 4.0 score of 5.3 (Medium) is consistent with the vulnerability's limited impact profile: confidentiality impact is low (VC:L), with no integrity (VI:N) or availability (VA:N) impact, and no subsequent-system scope (SC:N/SI:N/SA:N). … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario An attacker who has obtained or been legitimately issued a non-administrative Tenable Security Center account - such as a limited analyst or scan operator - authenticates to the Security Center web interface and queries settings endpoints or navigates configuration panels that belong to organizational scopes they have not been assigned to. This could expose scan policy configurations, organizational settings, or administrative parameters from peer scopes. …
Remediation Consult Tenable advisory TNS-2026-22 at https://www.tenable.com/security/tns-2026-22 for the primary fix and any specific patched version details, as no exact fix version is confirmed in the available data. … Detailed patch versions, workarounds, and compensating controls in full report.

Threat intelligence, references, and detailed analysis are available after sign-in.

CVE-2026-64879 CRITICAL
9.4 Jul 21

OS command injection in Tenable Security Center (Tenable.sc) lets an authenticated attacker execute arbitrary shell comm

CVE-2026-19681 CRITICAL
9.4 Aug 14

Authenticated OS command injection in Tenable Security Center allows a low-privileged user to run arbitrary operating sy

CVE-2026-19682 CRITICAL
9.4 Aug 14

OS command injection in Tenable Security Center (formerly Tenable.sc) lets a remote attacker run arbitrary operating-sys

CVE-2026-19626 CRITICAL
9.4 Aug 14

Remote code execution in Tenable Security Center's report-generation subsystem allows an authenticated, non-administrati

CVE-2026-64878 CRITICAL
9.4 Jul 21

Authenticated remote code execution in Tenable Security Center allows an attacker to inject shell metacharacters through

CVE-2026-64877 CRITICAL
9.4 Jul 21

SQL injection in the ticketing REST API of Tenable Security Center (versions before 6.8.0) allows an authenticated non-a

CVE-2026-19679 HIGH
8.7 Aug 14

Command injection in Tenable Security Center's file upload handler allows an authenticated low-privilege network attacke

CVE-2026-19628 HIGH
8.6 Aug 14

Command injection in Tenable Security Center enables an authenticated administrator to achieve arbitrary OS command exec

CVE-2026-64881 HIGH
8.7 Jul 21

OS command injection in Tenable Security Center (formerly Tenable.sc) lets authenticated users abuse the audit file uplo

CVE-2023-1522 HIGH
8.8 Apr 05

SQL Injection in the Hardware Inventory report of Security Center 5.11.2. Rated high severity (CVSS 8.8), this vulnerabi

CVE-2026-19629 HIGH
8.6 Aug 14

Privilege escalation in Tenable Security Center allows an authenticated Security Manager to manage users outside their a

CVE-2026-19635 HIGH
8.5 Aug 14

Command injection (CWE-78) in Tenable Security Center versions prior to 6.9.0 enables a local attacker with write access

Share

CVE-2026-19639 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy