Ac20 Firmware
CVE-2025-8940
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.4 (HIGH). Attack characteristics: network attack vector, low complexity, low privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 0.47%. |
| Exploit ScenarioDerived | A remote attacker could corrupt memory to execute arbitrary code or crash the application by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Affected by this vulnerability is the function strcpy of the file /goform/saveParentControlInfo. The manipulation of the argument Time leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Affected products include: Tenda Ac20 Firmware. Version information: up to 16.03.08.12..
Know when Ac20 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Affected by this vulnerability is the function strcpy of the file /goform/saveParentControlInfo. The manipulation of the argument Time leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Executive ViewAI
Organizations using Tenda AC20 face moderate risk from CVE-2025-8940, a buffer overflow vulnerability rated CVSS 7.4. Exploitation could allow attackers to corrupt memory, crash the application, or potentially execute arbitrary code. Proof-of-concept code is publicly available, increasing the risk of exploitation. Organizations should apply vendor updates when available and consider compensating controls in the interim.
Apply vendor patch. If immediate patching is not feasible: (1) Implement network-level access controls to limit exposure; (2) Enable enhanced monitoring and alerting; (3) Apply principle of least privilege.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Affected Products (CPE)CVE.org
More in Ac20 Firmware
View allStack-based buffer overflow in the Tenda AC20 router running firmware 16.03.08.12 allows a remote attacker to overwrite
A stack-based buffer overflow in the httpd component of Tenda AC20 firmware 16.03.08.12 allows a remote attacker to over
Stack-based buffer overflow in the Tenda AC20 router (firmware 16.03.08.12) allows an authenticated attacker who can rea
A weakness has been identified in Tenda AC20 16.03.08.05. Rated high severity (CVSS 7.4), this vulnerability is remotely
A vulnerability was detected in Tenda AC20 up to 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remo
Buffer overflow in the Tenda AC20 router firmware (up to and including 16.03.08.12) lets remote attackers corrupt memory
A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is re
A vulnerability was detected in Tenda AC20 up to 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remo
A vulnerability was determined in Tenda AC20 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remotely
A vulnerability was found in Tenda AC20 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remotely expl
A vulnerability has been found in Tenda AC20 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remotely
A vulnerability was identified in Tenda AC20 16.03.08.12. Rated high severity (CVSS 7.4), this vulnerability is remotely
GitHub PoC
Exploit-DB