MicroServer CVE-2025-64305
HIGHAttack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain physical access to MicroServer
-
DeliveryRemove/read external SD card
-
ExploitExtract plaintext user and vendor secrets
-
ExecutionAuthenticate to web portal as admin or forge firmware
-
ImpactFull device compromise
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V14 - Data Protection File/disk data protection
|
| Exploitation Conditions | Requires physical access to the unencrypted external SD card that the MicroServer writes at boot; the card holds plaintext copies of firmware parts containing user and vendor secrets. Exploitation is gated by that physical/media access - there is no evidence of remote retrieval of the SD contents. Once secrets are obtained, the attacker can authenticate to the web portal as admin or build modified vendor firmware, so the follow-on impact spans confidentiality and integrity. Limiting factors: physical proximity to the device and its SD slot, a niche OT weather-station deployment, and no user interaction or prior authentication otherwise needed. |
| Impact | This is a genuinely low-priority issue despite a moderate 7.1 CVSS 4.0 score. The core weakness (CWE-313, cleartext storage) exposes user and vendor secrets, but every signal points to limited real-world risk: EPSS is 0.01% (1st percentile), there is no CISA KEV listing (no confirmed active exploitation), and no public POC. The single strongest limiting factor is the access path - secrets reside on an EXTERNAL SD card that must be physically read. The vendor's CVSS 4.0 vector claims AV:A (adjacent/network-adjacent), which is inconsistent with a description centered on reading an unencrypted physical SD card; that vector should be verified with the vendor, as physical media access (AV:P) is the more defensible reading. The vendor also scored VC:H with VI:N/VA:N, yet the description explicitly states the stolen secrets let an attacker 'modify the vendor firmware, or gain admin access to the web portal' - that is a clear integrity impact the vendor vector omits. Net: high-confidence low priority because of the physical-access precondition and niche deployment, but the impact ceiling (firmware tampering + admin takeover) is higher than the 'Information Disclosure' tag suggests. |
| Exploit ScenarioDerived | An attacker with physical access to a deployed Columbia Weather MicroServer removes or reads its unencrypted external SD card, onto which the device copied firmware containing plaintext user and vendor secrets at boot. Using those credentials, the attacker logs into the web portal as an administrator or crafts modified vendor firmware for the device. No public exploit code has been identified at time of analysis. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Sep 30, 2026
MicroServer writes portions of its system firmware, including user and vendor secrets, to an unencrypted external SD card during boot. An attacker with physical access to the SD card can read these plaintext secrets and use them to modify vendor firmware or authenticate to the web portal as an administrator. The EPSS score is 0.01% (1st percentile); no public exploit identified at time of analysis.
Earlier versions of this analysis (1)
MicroServer copies parts of the system firmware to an unencrypted external SD card on boot, which contains user and vendor secrets. An attacker can utilize these plaintext secrets to modify the vendor firmware, or gain admin access to the web portal. [CVSS 6.5 MEDIUM]
RemediationAI
No vendor-released patch is identified at time of analysis; refer to CISA advisory ICSA-26-006-01 for the latest guidance. Because exploitation requires physical access to the SD card, the most effective compensating control is to restrict physical access to the device and its SD card slot to trusted personnel only. If the device must operate unattended, consider removing the external SD card after boot if operationally feasible, though this may disable logging or other SD-dependent functions. Alternatively, use an encrypted SD card if the firmware supports it, but be aware that the firmware may still write cleartext secrets to it. Rotate any user or vendor secrets that may have been exposed, and monitor the web portal for unauthorized admin logins or unexpected firmware changes. Network segmentation can help limit the impact if the secrets are used to compromise the device.
Affected ProductsAI
MicroServer devices that write system firmware copies to an external SD card on boot. No specific firmware version ranges are provided in the available data; consult CISA advisory ICSA-26-006-01 for the exact affected models and firmware revisions. The advisory is available at https://www.cisa.gov/news-events/ics-advisories/icsa-26-006-01 and a machine-readable CSAF file at https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-006-01.json.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-313: Cleartext Storage in a File or on Disk. The MicroServer firmware copies sensitive firmware components and secrets to an unencrypted external SD card on every boot, rather than storing them in encrypted internal memory or using secure storage. This design flaw exposes secrets to anyone who can physically access the SD card. The CVE record assigns a CVSS 4.0 score of 7.1 with an adjacent-network vector (AV:A), but the independent assessment places the realistic attack vector at physical access (AV:P), with high confidentiality and integrity impact but no availability impact. No CPE data is available; the affected device appears to be a niche OT weather-station deployment per the assessment.
Know when the next one hits your stack
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
Reading the external SD card requires physical media access (AV:P, not vendor's AV:A); recovered secrets enable both data disclosure (C:H) and firmware/admin modification (I:H); no availability impact.
Primary rating from Vendor (hq).
CVSS VectorVendor: hq
Lifecycle Timeline
3DescriptionCVE.org
MicroServer copies parts of the system firmware to an unencrypted external SD card on boot, which contains user and vendor secrets. An attacker can utilize these plaintext secrets to modify the vendor firmware, or gain admin access to the web portal.
Executive ViewAI
MicroServer devices store plaintext user and vendor secrets on an unencrypted external SD card during boot, and anyone with physical access to that card can obtain administrator-level web portal access or alter vendor firmware. This creates a hardware supply-chain and insider-risk exposure for organizations that deploy MicroServer in physically accessible locations, potentially undermining device integrity and administrative control. No public exploit identified at time of analysis; leadership should prioritize asset inventory and physical access controls while monitoring for a vendor patch.
No vendor-released patch identified at time of analysis. Interim mitigations: enforce strict physical access controls such as locked racks, tamper-evident seals, and access logs; remove or disable external SD card boot/write where possible; encrypt SD card contents if supported; rotate all user and vendor secrets; restrict admin web portal access to trusted networks; and monitor for unauthorized firmware changes.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
NVD
CVE.org
EPSS
GitHub
Exploit-DB