Skip to main content

Fh1203 Firmware CVE-2025-6113

| EUVDEUVD-2025-18378 HIGH
Buffer Overflow (CWE-119)
2025-06-16 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

4
EUVD ID Assigned
Mar 14, 2026 - 21:59 euvd
EUVD-2025-18378
Analysis Generated
Mar 14, 2026 - 21:59 vuln.today
PoC Detected
Jun 17, 2025 - 19:38 vuln.today
Public exploit code
CVE Published
Jun 16, 2025 - 08:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. Affected is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

AnalysisAI

Critical remote buffer overflow vulnerability in Tenda FH1203 firmware version 2.0.1.6 affecting the /goform/AdvSetLanip endpoint. An authenticated attacker can exploit improper input validation of the lanMask parameter to achieve remote code execution with full system compromise (confidentiality, integrity, and availability). A public proof-of-concept exploit exists, indicating active disclosure and potential real-world exploitation risk.

Technical ContextAI

The vulnerability exists in the fromadvsetlanip function within the Tenda FH1203 router's web administration interface. Tenda FH1203 is a residential WLAN router running proprietary firmware. The vulnerability is classified as CWE-119 (Improper Restriction of Operations within the Bounds of a Memory Buffer), a classic stack-based buffer overflow caused by insufficient bounds checking on the lanMask parameter. The affected endpoint /goform/AdvSetLanip handles LAN IP configuration requests and fails to validate the length of user-supplied input before copying it into a fixed-size buffer. This allows an authenticated attacker to overwrite adjacent stack memory, potentially hijacking control flow to execute arbitrary code with router privileges. CPE identifier: cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*

RemediationAI

Immediate actions: (1) Check for available firmware updates from Tenda's official support website or admin interface (Settings > System Tools > Firmware Upgrade). (2) If patched firmware is available for FH1203, upgrade immediately. (3) Temporary workarounds while awaiting patch: disable remote management access, restrict web interface access to trusted networks only via firewall rules, change default credentials to strong unique passwords, monitor router logs for suspicious /goform/AdvSetLanip requests. (4) Consider network segmentation to isolate router management traffic. (5) Monitor Tenda's security advisories at tenda.com.cn or regional support sites for patch availability. Without access to specific vendor advisory links in provided references, recommend checking Tenda support directly and security databases (NVD, Exploit-DB) for patch version information once released.

CVE-2024-30602 CRITICAL POC
9.8 Mar 28

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function. R

CVE-2023-38940 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38934 CRITICAL POC
9.8 Aug 07

Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the device

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-37707 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.

CVE-2023-37706 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function

CVE-2023-37705 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.

CVE-2023-37704 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState fu

CVE-2023-37703 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan func

CVE-2023-37702 CRITICAL POC
9.8 Jul 10

Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName fun

Share

CVE-2025-6113 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy