Skip to main content

Ac6 Firmware CVE-2025-5853

| EUVDEUVD-2025-17419 HIGH
Buffer Overflow (CWE-119)
2025-06-09 cna@vuldb.com
8.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 8.8. EPSS 0.3%. Public PoC/exploit available. No patch confirmed.

Exploit ScenarioDerived

An attacker could exploit this vulnerability in A vulnerability classified as critical to compromise the security of affected deployments, potentially impacting confidentiality, integrity, or availability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 14, 2026

A buffer overflow vulnerability in A vulnerability classified as critical (CVSS 8.8). Risk factors: public PoC available.

Earlier versions of this analysis (1)
v1 Mar 14, 2026 - 19:21 CVSS 8.8

A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of

RemediationAI

Monitor vendor channels for patch availability. Consider network segmentation to limit exposure if patching is delayed.

Affected VersionsENISA

AC6 15.03.05.16

Affected Packages

euvd ac6 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

CWE-119 (Buffer Overflow). CVSS 8.8 indicates high severity. Affects A vulnerability classified as critical.

Know when Ac6 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Jun 09, 2025 - 19:04 vuln.today
Public exploit code
CVE Published
Jun 09, 2025 - 01:15 nvd
HIGH 8.8

DescriptionCVE.org

A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Executive ViewAI

Why It Matters

A critical remote code execution vulnerability affecting Tenda AC6 routers (model 15.03.05.16) allows unauthenticated attackers to execute arbitrary code through a stack buffer overflow. Organizations using this device model face immediate risk of network compromise, data exfiltration, and lateral movement into connected systems, particularly concerning for businesses relying on these devices for network perimeter security.

Business Impact: High
Compensating Controls

Disable remote web management and SSH access on affected devices; implement strict network access controls (firewall rules) to block external access to the vulnerable endpoint (/goform/SetRemoteWebCfg); deploy WAF rules to block requests containing suspicious remoteIp parameters; segment affected devices onto isolated VLANs with limited trust; monitor for CVE-2025-5853 exploitation attempts in network logs; consider temporary device shutdown if replacement is imminent; monitor Tenda security advisories for emergency patches.

Threat Intelligence Overview

EPSS Score
0.3%
Top 45% exploitable
Exploit
POC
Public exploit code exists
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact
High

Priority Score

64
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2024-52714 CRITICAL POC
9.8 Nov 19

Tenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. Rated critical

CVE-2025-25343 CRITICAL POC
9.8 Feb 12

Tenda AC6 V15.03.05.16 firmware has a buffer overflow vulnerability in the formexeCommand function. Rated critical sever

CVE-2025-29031 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function. Rated critical sever

CVE-2025-29030 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated critical sever

CVE-2025-29029 CRITICAL POC
9.8 Mar 14

Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. Rated critical seve

CVE-2023-40838 CRITICAL POC
9.8 Aug 30

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. Rate

CVE-2023-40846 CRITICAL POC
9.8 Aug 28

Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. Rated critic

CVE-2023-38937 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC

CVE-2023-38936 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,

CVE-2023-38933 CRITICAL POC
9.8 Aug 07

Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0

CVE-2023-38931 CRITICAL POC
9.8 Aug 07

Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1

CVE-2023-2923 CRITICAL POC
9.8 May 27

A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Rated critical severity (CVSS 9

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy