HIGHCVSS VectorNVD
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
2DescriptionNVD
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSystemConfig functionality to modify relevant device properties (such as network settings), contradicting the security model proposed in the user manual.
AnalysisAI
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Incorrect Permission Assignment (CWE-732), which allows attackers to access resources due to misconfigured permissions. Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSystemConfig functionality to modify relevant device properties (such as network settings), contradicting the security model proposed in the user manual.
Affected ProductsAI
See vendor advisory for affected versions.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and restrict file/resource permissions, apply principle of least privilege.