Skip to main content

HCL MyXalytics CVE-2025-52651

| EUVDEUVD-2025-210859 LOW
Improper Input Validation (CWE-20)
2026-09-07 HCL GHSA-frcx-2mrg-6xg4
3.5
CVSS 3.1 · Vendor: HCL

Severity by source

Vendor (HCL) PRIMARY
3.5 LOW
AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N
vuln.today AI
3.5 LOW

Network-reachable but requires authenticated low-privilege session and user interaction; impact is integrity-only at low severity, no confidentiality or availability consequence.

3.1 AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N
4.0 AV:N/AC:L/AT:N/PR:L/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (HCL).

CVSS VectorVendor: HCL

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
Required
Scope
Unchanged
Confidentiality
None
Integrity
Low
Availability
None

Lifecycle Timeline

2
Metadata Corrected
Sep 07, 2026 - 11:40 vuln.today
tag: Information Disclosure removed
Analysis Generated
Sep 07, 2026 - 11:07 vuln.today

DescriptionCVE.org

HCL MyXalytics was affected by Improper Input validation Vulnerability. It allow malicious or unexpected data to cause unintended system behaviour or security issues.

AnalysisAI

Improper input validation in HCL MyXalytics allows an authenticated low-privileged user to submit malicious or unexpected data through the application, causing unintended system behavior or minor integrity-affecting outcomes. The CVSS vector (PR:L/UI:R/I:L) indicates exploitation requires both an authenticated session and user interaction, with impact limited to low-level integrity modification and no confidentiality exposure. No public exploit code has been identified and this vulnerability is not listed in the CISA KEV catalog.

Technical ContextAI

CWE-20 (Improper Input Validation) describes a failure to validate or sanitize user-supplied input before it is processed by the application. In web-based analytics platforms like HCL MyXalytics (CPE: cpe:2.3:a:hcl_software:myxalytics:*:*:*:*:*:*:*:*), this class of flaw typically manifests in form fields, API parameters, or data import workflows where user-controlled values are passed to backend logic without sufficient bounds or format checking. The wildcard CPE version field indicates HCL has not disclosed the specific affected version range in the available NVD/CPE data. The CVSS vector AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N confirms the vulnerability is reachable over the network but limited in practical impact.

RemediationAI

Consult HCL Software's advisory KB0132828 at https://support.hcl-software.com/csm?id=kb_article&sysparm_article=KB0132828 for the specific patched version and update instructions. No exact fix version is independently confirmed from available CPE or reference data. As a compensating control while patching, restrict access to the affected HCL MyXalytics instance to authenticated corporate users only, enforce least-privilege account policies so low-privilege accounts cannot reach sensitive input paths, and apply web application firewall rules to reject anomalous input patterns at the perimeter.

Share

CVE-2025-52651 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy