Skip to main content

Nozomi Networks Guardian CVE-2025-40886

HIGH
SQL Injection (CWE-89)
2025-10-07 prodsec@nozominetworks.com
7.7
CVSS 4.0 · Vendor: nozominetworks
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Authenticate with low-privilege account
  2. Delivery
    Reach Alert functionality endpoint
  3. Exploit
    Inject SQL via unvalidated parameter
  4. Execution
    Execute arbitrary SQL on DBMS
  5. Impact
    Exfiltrate or alter database data

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Persistence

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Requires an authenticated session with a low-privilege account (PR:L) on the web interface of Nozomi Networks Guardian or CMC; the attack targets a specific unvalidated input parameter within the Alert functionality. Limiting factors that reduce real-world exploitability: valid credentials are mandatory (no unauthenticated path), high attack complexity (AC:H) and a present attack requirement (AT:P) indicate success depends on conditions the attacker does not fully control, and these appliances are typically deployed on segmented OT/monitoring networks rather than internet-exposed, further narrowing the realistic attacker population to insiders or those who have already gained a foothold.

Impact

This is a meaningful but not emergency-grade issue. The CVSS 4.0 vector (AV:N/AC:H/AT:P/PR:L/UI:N) scores 7.7 (High) and reflects a network-reachable SQL injection, but three factors temper real-world risk: it requires authentication (PR:L - an existing low-privilege account), it carries high attack complexity (AC:H) plus a present attack requirement (AT:P), meaning exploitation depends on conditions outside the attacker's control rather than being a trivial push-button attack. Impact is severe where it applies (VC:H/VI:H/VA:H - full confidentiality, integrity, and availability compromise of the database) but scope is unchanged (SC:N/SI:N/SA:N), so impact is confined to the application's DBMS. There is no CISA KEV listing and no public exploit identified at time of analysis, so there is no evidence of active exploitation or weaponization. EPSS was not provided and should not be assumed. Net: a legitimate patch priority for organizations running these OT/IoT monitoring appliances - especially because the affected products sit in sensitive industrial/critical-infrastructure networks - but the authentication requirement and high complexity make it a lower urgency than an unauthenticated RCE. The vendor (Nozomi) both reported and advised on the issue, which raises confidence in the finding's validity.

Exploit ScenarioDerived

An attacker who already holds a low-privilege account on a Nozomi Networks Guardian or CMC web interface submits a crafted value to the vulnerable input parameter in the Alert functionality, injecting SQL that the application passes unsanitized to its database. Because the flaw is network-reachable but requires valid credentials and specific conditions (AC:H/AT:P), the realistic actor is a malicious insider or an attacker who has already obtained limited credentials (e.g., via phishing or reuse). No public exploit code was identified at time of analysis.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 18, 2026

SQL injection in Nozomi Networks Guardian and CMC's Alert functionality allows an authenticated low-privilege user to execute arbitrary SQL against the underlying DBMS, potentially reading, altering, or destroying application data. No public exploit code or CISA KEV entry was identified at time of analysis, and the high attack complexity, present attack requirement, and need for valid credentials limit practical exploitation to insiders or attackers with an existing foothold. This is a meaningful but not emergency-grade issue for typical OT/monitoring deployments.

RemediationAI

Apply the fixed release identified in Nozomi Networks advisory NN-2025:7-01 at https://security.nozominetworks.com/NN-2025:7-01; the provided intelligence does not specify an exact patched version, so confirm the applicable update for Guardian and CMC before deployment. Until the update is applied, restrict access to the web interface and Alert functionality to trusted administrative networks, remove or limit unnecessary low-privilege accounts that can reach the Alert feature, and monitor for anomalous SQL errors or database activity from authenticated sessions. Network restrictions reduce monitoring convenience for legitimate operators, and account cleanup may disrupt workflows that depend on those users.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The issue is a CWE-89 SQL injection in the Alert functionality of Nozomi Networks Guardian and CMC, where an input parameter is not properly validated before being incorporated into SQL statements. The affected components are the Guardian and CMC web applications, identified by CPE entries cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:* and cpe:2.3:a:nozominetworks:cmc:*:*:*:*:*:*:*:*. Exploitation requires an authenticated session with a low-privilege account on the web interface (CVSS PR:L), and the assessed CVSS:3.1 vector shows high attack complexity (AC:H) and a present attack requirement (AT:P), meaning success depends on conditions the attacker does not fully control. Because these appliances are typically deployed on segmented OT/monitoring networks rather than exposed to the internet, the realistic attacker population is narrowed to insiders or those who have already gained a foothold. The vulnerability does not by itself provide unauthenticated access or expand scope beyond the vulnerable component.

Know when Cmc gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (nozominetworks) PRIMARY 7.7 HIGH
CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
vuln.today AI 7.5 HIGH

Network-reachable injection but needs valid low-privilege credentials (PR:L) and non-trivial conditions (AC:H folds in the 4.0 AT:P); full DBMS C/I/A impact, scope unchanged as the DB is in-application.

3.1 AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (nozominetworks).

CVSS VectorVendor: nozominetworks

Attack Vector
Network
Attack Complexity
High
Attack Requirements
Present
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A SQL Injection vulnerability was discovered in the Alert functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SQL statements on the DBMS used by the web application, potentially exposing unauthorized data, altering their structure and content, and/or affecting their availability.

Executive ViewAI

Why It Matters

Nozomi Networks Guardian and CMC contain a high-severity SQL injection in the Alert function that could allow an existing low-privilege user to read, alter, or destroy application data. Because exploitation requires valid credentials and high attack complexity, and no public exploit identified at time of analysis, the immediate risk is concentrated among insiders or attackers who already have a foothold. Leadership should prioritize access governance and monitoring for these OT visibility platforms; no vendor-released patch identified at time of analysis.

Business Impact: Medium
Compensating Controls

No vendor-released patch identified at time of analysis; restrict Alert functionality to trusted administrators, enforce least privilege, monitor database activity for anomalous SQL, segment management interfaces, and review Nozomi Networks advisories for interim mitigations.

Threat Intelligence Overview

EPSS Score
0.3%
Top 83% exploitable
Prevalence
Medium
specific OT/IoT security vendor appliances, common in industrial networks not everywhere
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
No
Human Impact
Medium

Priority Score

38
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +38
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.

Affected Products (CPE)CVE.org

cpe:2.3:a:nozominetworks:cmc:*:*:*:*:*:*:*:*
cpe:2.3:a:nozominetworks:guardian:*:*:*:*:*:*:*:*

More in Cmc

View all
CVE-2023-29245 CRITICAL
9.2 Sep 19

A SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain fields us

CVE-2026-31984 HIGH
8.7 Jul 09

Disk-exhaustion denial of service in Nozomi Networks Guardian and Central Management Console (CMC) lets a remote, unauth

CVE-2023-2567 HIGH
8.7 Sep 19

A SQL Injection vulnerability has been found in Nozomi Networks Guardian and CMC, due to improper input validation in ce

CVE-2023-23574 HIGH
8.7 Aug 09

A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the alerts_

CVE-2023-22378 HIGH
8.7 Aug 09

A blind SQL Injection vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in the sorting

CVE-2022-0551 HIGH
8.6 Mar 24

Improper Input Validation vulnerability in project file upload in Nozomi Networks Guardian and CMC allows an authenticat

CVE-2022-0550 HIGH
8.6 Mar 24

Improper Input Validation vulnerability in custom report logo upload in Nozomi Networks Guardian, and CMC allows an auth

CVE-2023-32649 HIGH
8.2 Sep 19

A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian and CMC, due to improper input validation in certain

CVE-2026-33924 HIGH
7.5 Oct 29

OS command injection in Nozomi Networks Guardian and CMC before 26.4.0 allows an attacker who already holds administrati

CVE-2026-33923 HIGH
7.5 Oct 29

A signature-verification bypass in the update-installation functionality of Nozomi Networks Guardian and CMC before 26.4

CVE-2023-22843 HIGH
7.3 Aug 09

An authenticated attacker with administrative access to the web management interface can inject malicious JavaScript cod

CVE-2026-33390 HIGH
7.2 Jul 09

Privilege escalation via configuration synchronization in Nozomi Networks Guardian and Central Management Console (CMC)

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy