Skip to main content

Growatt ShineLan-X CVE-2025-36751

CRITICAL
Missing Encryption of Sensitive Data (CWE-311)
2025-12-13 csirt@divd.nl
9.4
CVSS 4.0 · Vendor: divd
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain adjacent network access to inverter LAN
  2. Delivery
    Position on-path via ARP/MITM
  3. Exploit
    Intercept unencrypted inverter-to-cloud traffic
  4. Execution
    Read/alter configuration requests
  5. Impact
    Disclose data or tamper with cloud communication

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V14 - Data Protection Encryption of sensitive data
Exploitation Conditions

Exploitation requires the attacker to hold an adjacent-network position (AV:A) - on the same LAN/Wi-Fi segment as the Growatt ShineLan-X communication module or MIC 3300TL-X inverter - and to be able to observe or intercept the traffic path between the inverter and its cloud endpoint (e.g., via an on-path/MITM technique such as ARP spoofing). The enabling condition is architectural rather than configuration-specific: the configuration interface transmits data without encryption (CWE-311), so no special feature toggle is needed, but exploitation is LIMITED by the requirement for local/adjacent network access (not routable internet exploitation), by the need for an on-path position to do more than passively eavesdrop, and by the description's hedged 'potentially manipulate' - active tampering is plausible but not confirmed as a reliable primitive.

Impact

Signals are mixed and point to a serious-but-position-limited flaw rather than a mass-exploitation emergency. The input CVSS 4.0 vector (AV:A/AC:L/PR:N/UI:N with full Vulnerable- and Subsequent-system Confidentiality/Integrity/Availability High) drives the 9.4 critical score, but the AV:A metric is the key limiter: this is adjacent-network, not internet-wide (AV:N), so an attacker must already share the local network segment with the inverter or its ShineLan-X communication dongle. The EPSS score is very low (0.07%, 0th percentile), the CVE is NOT in CISA KEV, and no public exploit is identified - all three low-signal indicators are consistent with each other and with a missing-encryption/MITM class issue (CWE-311) that requires an on-path network position rather than a point-and-click remote exploit. CONFLICT TO NOTE: the input vector marks subsequent-system impact High (SC:H/SI:H/SA:H) and availability High (VA:H), which seems aggressive for a flaw the description only characterizes as allowing an attacker to 'intercept and potentially manipulate' cloud communication - the word 'potentially' and the absence of any described code-execution or device-takeover primitive suggest integrity/availability impact is speculative and may be overstated; verify with the DIVD/vendor advisory. Net: treat as a real priority for networks where these inverters sit on untrusted/shared LANs (solar installations, shared OT segments), but it is not a drop-everything internet-facing threat.

Exploit ScenarioDerived

An attacker who gains a foothold on the same local or Wi-Fi network as a Growatt ShineLan-X module or MIC 3300TL-X inverter positions themselves on-path (e.g., via ARP spoofing) and passively captures the unencrypted configuration/cloud traffic, exposing operational and potentially credential data. Because the channel lacks encryption and integrity protection, the attacker can then attempt to alter the requests flowing between the inverter and its cloud endpoint. No public proof-of-concept exploit is known at the time of analysis, and exploitation requires adjacent-network access rather than remote internet reach.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 07, 2026

Unencrypted configuration traffic in Growatt ShineLan-X communication modules and MIC 3300TL-X inverters exposes inverter-to-cloud communications to interception and possible manipulation by an unauthenticated attacker positioned on the adjacent network (CVSS 4.0 base 9.4; independent assessment CVSS 3.1 AV:A/AC:L/PR:N/UI:N with high confidentiality and integrity impact, limited availability impact). The attacker must share the same LAN/Wi-Fi segment as the device and be able to see or sit on the traffic path (for example via an on-path/MITM technique such as ARP spoofing), so exploitation is position-limited rather than internet-routable. EPSS is 0.07% (0th percentile) and no public exploit code or confirmed active exploitation has been identified at time of analysis; the description's ability to actively tamper with requests is hedged as 'potentially', so passive eavesdropping is the more reliable primitive.

RemediationAI

No vendor-released patch has been identified at time of analysis, so remediation must currently rely on compensating controls; check the DIVD advisory (https://csirt.divd.nl/CVE-2025-36751/) and Growatt's own security channels for a firmware fix. The most effective immediate control is network isolation: place the ShineLan-X module and MIC 3300TL-X inverter on a dedicated VLAN or SSID (or an OT/IoT segmentation zone) that is firewalled from user and guest networks, which removes the adjacent-network foothold the attack requires - the trade-off is that cloud reporting and remote management still need a narrowly scoped outbound path, and local installer tooling may lose direct access. Harden the layer-2 segment against on-path positioning by enabling Dynamic ARP Inspection, DHCP snooping, and static ARP entries for the inverter and its gateway, and by using WPA3 (or WPA2 with PMF) with certificate-based 802.1X on the Wi-Fi the module uses; these add configuration overhead and can break legacy or static-IP setups, and static ARP entries require re-editing whenever hardware is replaced. Monitoring and detection are useful but do not remove the flaw: watch for ARP poisoning signatures, unexpected DHCP servers or rogue APs, and anomalous egress from the inverter's MAC/IP, accepting that such detection is after-the-fact. Finally, do not expose the affected devices' management or configuration interfaces to untrusted networks, since the absence of encryption means any on-path observer retains full read access to the proxied traffic.

Affected ProductsAI

Two Growatt products are implicated: the ShineLan-X communication/data-logger module and the MIC 3300TL-X string inverter, both affected in their configuration-interface and cloud-communication behavior. The CVE was reported by the DIVD CSIRT (csirt@divd.nl), and the sole reference on record is the DIVD advisory at https://csirt.divd.nl/CVE-2025-36751/, which should be consulted for the authoritative hardware and firmware scope. No CPE strings, firmware version boundaries, or vendor advisory are present in the provided data, so exact affected firmware builds cannot be enumerated from available sources; operators should treat all units of these models as in scope unless the vendor states otherwise.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The flaw is an instance of CWE-311, Missing Encryption of Sensitive Data, in the configuration interface of Growatt ShineLan-X data-logger/communication modules and MIC 3300TL-X string inverters. Rather than a memory-safety or logic bug, this is an architectural omission: the device-to-cloud protocol transmits configuration and telemetry without transport encryption (no TLS/confidentiality layer), so any party able to observe the link sees the payload in cleartext. The CVSS 4.0 vector rates the attack vector as Adjacent (AV:A) with no privileges (PR:N) or user interaction (UI:N) required, which maps to an attacker already present on the same network segment as the inverter or its logger - consistent with the independent assessment's AV:A/AC:L/PR:N/UI:N rating. Because the enabling condition is the absence of encryption rather than a misconfiguration, and because the affected devices are behind a home, commercial, or utility LAN, the realistic threat model is intra-segment interception, for example ARP spoofing or a rogue DHCP/AP position, rather than scalable remote exploitation from the internet.

Know when Growatt gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (divd) PRIMARY 9.4 CRITICAL
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 8.3 HIGH

Adjacent on-path position (AV:A) with no auth or interaction; missing encryption yields C:H and I:H (interception + manipulation), while availability impact is only potential, so A:L and scope unchanged.

3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N

Primary rating from Vendor (divd).

CVSS VectorVendor: divd

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.

Executive ViewAI

Why It Matters

Growatt ShineLan-X communication modules and MIC 3300TL-X inverters are affected by a critical unencrypted communications issue that could expose inverter-to-cloud configuration traffic to interception or potential tampering by an unauthenticated attacker on the same local network segment. The exposure is position-limited and not internet-routable, but successful exploitation could undermine the confidentiality and integrity of operational energy data at affected sites. Leadership should prioritize network isolation and monitoring of these solar assets while no vendor-released patch is identified at time of analysis.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include isolating Growatt ShineLan-X and MIC 3300TL-X devices on dedicated VLANs/SSIDs, restricting adjacent network access, monitoring for ARP spoofing/on-path activity, enforcing WPA3/802.1X where supported, and limiting outbound traffic to required cloud endpoints.

Threat Intelligence Overview

EPSS Score
0.1%
Top 100% exploitable
Prevalence
Medium
major solar-inverter vendor, but these specific inverter/dongle models are niche
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
High

Priority Score

47
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +47
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

CVE-2025-36752 CRITICAL
9.4 Dec 13

Growatt ShineLan-X communication dongles contain an undocumented backup account with hardcoded credentials, enabling adj

CVE-2025-36747 CRITICAL
9.4 Dec 13

File replacement in Growatt ShineLan-X firmware is possible for adjacent-network attackers who recover hard-coded FTP cr

CVE-2025-24297 CRITICAL
9.3 Apr 15

Due to lack of server-side input validation, attackers can inject malicious JavaScript code into users personal spaces o

CVE-2025-30510 CRITICAL
9.3 Apr 15

An attacker can upload an arbitrary file instead of a plant image. Rated critical severity (CVSS 9.3), this vulnerabilit

CVE-2025-30511 HIGH
8.7 Apr 15

An authenticated attacker can achieve stored XSS by exploiting improper sanitization of the plant name value while addin

CVE-2025-36753 HIGH
8.6 Dec 13

Physical attackers with brief hands-on access to a Growatt ShineLan-X communication dongle can attach an SWD hardware de

CVE-2025-36750 HIGH
8.6 Dec 13

Stored cross-site scripting in the Plant Name field of the Growatt ShineLan-X datalogger web interface allows an authent

CVE-2025-36748 HIGH
8.4 Dec 13

Stored cross-site scripting in the Growatt ShineLAN-X communication module's local configuration web server allows an at

CVE-2025-30512 MEDIUM
6.9 Apr 15

Unauthenticated attackers can send configuration settings to device and possible perform physical actions remotely (e.g.

CVE-2025-31360 MEDIUM
6.9 Apr 15

Unauthenticated attackers can trigger device actions associated with specific "scenes" of arbitrary users. Rated medium

CVE-2025-27565 MEDIUM
6.9 Apr 15

An unauthenticated attacker can delete any user's "rooms" by knowing the user's and room IDs. Rated medium severity (CVS

CVE-2025-27561 MEDIUM
6.9 Apr 15

Unauthenticated attackers can rename "rooms" of arbitrary users. Rated medium severity (CVSS 6.9), this vulnerability is

References

Advisories & patches

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy