Growatt ShineLan-X
CVE-2025-36751
CRITICAL
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain adjacent network access to inverter LAN
-
DeliveryPosition on-path via ARP/MITM
-
ExploitIntercept unencrypted inverter-to-cloud traffic
-
ExecutionRead/alter configuration requests
-
ImpactDisclose data or tamper with cloud communication
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V14 - Data Protection Encryption of sensitive data
|
| Exploitation Conditions | Exploitation requires the attacker to hold an adjacent-network position (AV:A) - on the same LAN/Wi-Fi segment as the Growatt ShineLan-X communication module or MIC 3300TL-X inverter - and to be able to observe or intercept the traffic path between the inverter and its cloud endpoint (e.g., via an on-path/MITM technique such as ARP spoofing). The enabling condition is architectural rather than configuration-specific: the configuration interface transmits data without encryption (CWE-311), so no special feature toggle is needed, but exploitation is LIMITED by the requirement for local/adjacent network access (not routable internet exploitation), by the need for an on-path position to do more than passively eavesdrop, and by the description's hedged 'potentially manipulate' - active tampering is plausible but not confirmed as a reliable primitive. |
| Impact | Signals are mixed and point to a serious-but-position-limited flaw rather than a mass-exploitation emergency. The input CVSS 4.0 vector (AV:A/AC:L/PR:N/UI:N with full Vulnerable- and Subsequent-system Confidentiality/Integrity/Availability High) drives the 9.4 critical score, but the AV:A metric is the key limiter: this is adjacent-network, not internet-wide (AV:N), so an attacker must already share the local network segment with the inverter or its ShineLan-X communication dongle. The EPSS score is very low (0.07%, 0th percentile), the CVE is NOT in CISA KEV, and no public exploit is identified - all three low-signal indicators are consistent with each other and with a missing-encryption/MITM class issue (CWE-311) that requires an on-path network position rather than a point-and-click remote exploit. CONFLICT TO NOTE: the input vector marks subsequent-system impact High (SC:H/SI:H/SA:H) and availability High (VA:H), which seems aggressive for a flaw the description only characterizes as allowing an attacker to 'intercept and potentially manipulate' cloud communication - the word 'potentially' and the absence of any described code-execution or device-takeover primitive suggest integrity/availability impact is speculative and may be overstated; verify with the DIVD/vendor advisory. Net: treat as a real priority for networks where these inverters sit on untrusted/shared LANs (solar installations, shared OT segments), but it is not a drop-everything internet-facing threat. |
| Exploit ScenarioDerived | An attacker who gains a foothold on the same local or Wi-Fi network as a Growatt ShineLan-X module or MIC 3300TL-X inverter positions themselves on-path (e.g., via ARP spoofing) and passively captures the unencrypted configuration/cloud traffic, exposing operational and potentially credential data. Because the channel lacks encryption and integrity protection, the attacker can then attempt to alter the requests flowing between the inverter and its cloud endpoint. No public proof-of-concept exploit is known at the time of analysis, and exploitation requires adjacent-network access rather than remote internet reach. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 07, 2026
Unencrypted configuration traffic in Growatt ShineLan-X communication modules and MIC 3300TL-X inverters exposes inverter-to-cloud communications to interception and possible manipulation by an unauthenticated attacker positioned on the adjacent network (CVSS 4.0 base 9.4; independent assessment CVSS 3.1 AV:A/AC:L/PR:N/UI:N with high confidentiality and integrity impact, limited availability impact). The attacker must share the same LAN/Wi-Fi segment as the device and be able to see or sit on the traffic path (for example via an on-path/MITM technique such as ARP spoofing), so exploitation is position-limited rather than internet-routable. EPSS is 0.07% (0th percentile) and no public exploit code or confirmed active exploitation has been identified at time of analysis; the description's ability to actively tamper with requests is hedged as 'potentially', so passive eavesdropping is the more reliable primitive.
RemediationAI
No vendor-released patch has been identified at time of analysis, so remediation must currently rely on compensating controls; check the DIVD advisory (https://csirt.divd.nl/CVE-2025-36751/) and Growatt's own security channels for a firmware fix. The most effective immediate control is network isolation: place the ShineLan-X module and MIC 3300TL-X inverter on a dedicated VLAN or SSID (or an OT/IoT segmentation zone) that is firewalled from user and guest networks, which removes the adjacent-network foothold the attack requires - the trade-off is that cloud reporting and remote management still need a narrowly scoped outbound path, and local installer tooling may lose direct access. Harden the layer-2 segment against on-path positioning by enabling Dynamic ARP Inspection, DHCP snooping, and static ARP entries for the inverter and its gateway, and by using WPA3 (or WPA2 with PMF) with certificate-based 802.1X on the Wi-Fi the module uses; these add configuration overhead and can break legacy or static-IP setups, and static ARP entries require re-editing whenever hardware is replaced. Monitoring and detection are useful but do not remove the flaw: watch for ARP poisoning signatures, unexpected DHCP servers or rogue APs, and anomalous egress from the inverter's MAC/IP, accepting that such detection is after-the-fact. Finally, do not expose the affected devices' management or configuration interfaces to untrusted networks, since the absence of encryption means any on-path observer retains full read access to the proxied traffic.
Affected ProductsAI
Two Growatt products are implicated: the ShineLan-X communication/data-logger module and the MIC 3300TL-X string inverter, both affected in their configuration-interface and cloud-communication behavior. The CVE was reported by the DIVD CSIRT (csirt@divd.nl), and the sole reference on record is the DIVD advisory at https://csirt.divd.nl/CVE-2025-36751/, which should be consulted for the authoritative hardware and firmware scope. No CPE strings, firmware version boundaries, or vendor advisory are present in the provided data, so exact affected firmware builds cannot be enumerated from available sources; operators should treat all units of these models as in scope unless the vendor states otherwise.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The flaw is an instance of CWE-311, Missing Encryption of Sensitive Data, in the configuration interface of Growatt ShineLan-X data-logger/communication modules and MIC 3300TL-X string inverters. Rather than a memory-safety or logic bug, this is an architectural omission: the device-to-cloud protocol transmits configuration and telemetry without transport encryption (no TLS/confidentiality layer), so any party able to observe the link sees the payload in cleartext. The CVSS 4.0 vector rates the attack vector as Adjacent (AV:A) with no privileges (PR:N) or user interaction (UI:N) required, which maps to an attacker already present on the same network segment as the inverter or its logger - consistent with the independent assessment's AV:A/AC:L/PR:N/UI:N rating. Because the enabling condition is the absence of encryption rather than a misconfiguration, and because the affected devices are behind a home, commercial, or utility LAN, the realistic threat model is intra-segment interception, for example ARP spoofing or a rogue DHCP/AP position, rather than scalable remote exploitation from the internet.
Know when Growatt gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Adjacent on-path position (AV:A) with no auth or interaction; missing encryption yields C:H and I:H (interception + manipulation), while availability impact is only potential, so A:L and scope unchanged.
Primary rating from Vendor (divd).
CVSS VectorVendor: divd
DescriptionCVE.org
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
Executive ViewAI
Growatt ShineLan-X communication modules and MIC 3300TL-X inverters are affected by a critical unencrypted communications issue that could expose inverter-to-cloud configuration traffic to interception or potential tampering by an unauthenticated attacker on the same local network segment. The exposure is position-limited and not internet-routable, but successful exploitation could undermine the confidentiality and integrity of operational energy data at affected sites. Leadership should prioritize network isolation and monitoring of these solar assets while no vendor-released patch is identified at time of analysis.
No vendor-released patch identified at time of analysis. Interim mitigations include isolating Growatt ShineLan-X and MIC 3300TL-X devices on dedicated VLANs/SSIDs, restricting adjacent network access, monitoring for ARP spoofing/on-path activity, enforcing WPA3/802.1X where supported, and limiting outbound traffic to required cloud endpoints.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Growatt ShineLan-X communication dongles contain an undocumented backup account with hardcoded credentials, enabling adj
File replacement in Growatt ShineLan-X firmware is possible for adjacent-network attackers who recover hard-coded FTP cr
Due to lack of server-side input validation, attackers can inject malicious JavaScript code into users personal spaces o
An attacker can upload an arbitrary file instead of a plant image. Rated critical severity (CVSS 9.3), this vulnerabilit
An authenticated attacker can achieve stored XSS by exploiting improper sanitization of the plant name value while addin
Physical attackers with brief hands-on access to a Growatt ShineLan-X communication dongle can attach an SWD hardware de
Stored cross-site scripting in the Plant Name field of the Growatt ShineLan-X datalogger web interface allows an authent
Stored cross-site scripting in the Growatt ShineLAN-X communication module's local configuration web server allows an at
Unauthenticated attackers can send configuration settings to device and possible perform physical actions remotely (e.g.
Unauthenticated attackers can trigger device actions associated with specific "scenes" of arbitrary users. Rated medium
An unauthenticated attacker can delete any user's "rooms" by knowing the user's and room IDs. Rated medium severity (CVS
Unauthenticated attackers can rename "rooms" of arbitrary users. Rated medium severity (CVSS 6.9), this vulnerability is
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB