Junos
CVE-2025-30658
HIGH
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:X
Lifecycle Timeline
2DescriptionCVE.org
A Missing Release of Memory after Effective Lifetime vulnerability in the Anti-Virus processing of Juniper Networks Junos OS on SRX Series
allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS).
On all SRX platforms with Anti-Virus enabled, if a server sends specific content in the HTTP body of a response to a client request, these packets are queued by Anti-Virus processing in Juniper Buffers (jbufs) which are never released. When these jbufs are exhausted, the device stops forwarding all transit traffic.
A jbuf memory leak can be noticed from the following logs:
(<node>.)<fpc> Warning: jbuf pool id <#> utilization level (<current level>%) is above <threshold>%!
To recover from this issue, the affected device needs to be manually rebooted to free the leaked jbufs.
This issue affects Junos OS on SRX Series:
- all versions before 21.2R3-S9,
- 21.4 versions before 21.4R3-S10,
- 22.2 versions before 22.2R3-S6,
- 22.4 versions before 22.4R3-S6,
- 23.2 versions before 23.2R2-S3,
- 23.4 versions before 23.4R2-S3,
- 24.2 versions before 24.2R2.
AnalysisAI
A Missing Release of Memory after Effective Lifetime vulnerability in the Anti-Virus processing of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Memory Leak (CWE-401), which allows attackers to exhaust available memory leading to denial of service. A Missing Release of Memory after Effective Lifetime vulnerability in the Anti-Virus processing of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS). On all SRX platforms with Anti-Virus enabled, if a server sends specific content in the HTTP body of a response to a client request, these packets are queued by Anti-Virus processing in Juniper Buffers (jbufs) which are never released. When these jbufs are exhausted, the device stops forwarding all transit traffic. A jbuf memory leak can be noticed from the following logs: (<node>.)<fpc> Warning: jbuf pool id <#> utilization level (<current level>%) is above <threshold>%! To recover from this issue, the affected device needs to be manually rebooted to free the leaked jbufs.2R3-S9, * 21.4 versions before 21.4R3-S10, * 22.2 versions before 22.2R3-S6, * 22.4 versions before 22.4R3-S6, * 23.2 versions before 23.2R2-S3, * 23.4 versions before 23.4R2-S3, * 24.2 versions before 24.2R2. Affected products include: Juniper Junos. Version information: before 21.2.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Ensure all allocated memory is properly freed. Use RAII patterns or garbage-collected languages.
named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 does not properly handle DNAME records when parsing fe
named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 allows remote attackers to cause a denial of service (
A PHP External Variable Modification vulnerability in J-Web of Juniper Networks Junos OS on EX Series and SRX Series all
jsdm/ajax/port.php in J-Web in Juniper Junos before 10.4R13, 11.4 before 11.4R7, 12.1 before 12.1R5, 12.2 before 12.2R3,
Juniper Junos 11.4 before R11, 12.1 before R9, 12.1X44 before D30, 12.1X45 before D20, 12.1X46 before D15, 12.1X47 befor
NFX Series devices using Juniper Networks Junos OS are susceptible to a local command execution vulnerability thereby al
NFX Series devices using Juniper Networks Junos OS are susceptible to a local code execution vulnerability thereby allow
Insufficient validation of environment variables in the telnet client supplied in Junos OS can lead to stack-based buffe
An Out-of-Bounds Write vulnerability in the H.323 ALG of Juniper Networks Junos OS allows an unauthenticated, network-ba
On QFX10000 Series devices using Juniper Networks Junos OS when configured as transit IP/MPLS penultimate hop popping (P
A Missing Release of Memory after Effective Lifetime vulnerability in the kernel of Juniper Networks Junos OS allows an
An Uncontrolled Memory Allocation vulnerability leading to a Heap-based Buffer Overflow in the packet forwarding engine
Same weakness CWE-401 – Memory Leak
View allSame technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today