Ac21 Firmware
CVE-2025-13445
HIGH
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
3DescriptionCVE.org
A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing a manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used.
AnalysisAI
A flaw has been found in Tenda AC21 16.03.08.16. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A flaw has been found in Tenda AC21 16.03.08.16. This affects an unknown part of the file /goform/SetIpMacBind. Executing a manipulation of the argument list can lead to stack-based buffer overflow. The attack can be executed remotely. The exploit has been published and may be used. Affected products include: Tenda Ac21 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.
More in Ac21 Firmware
View allA security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Rated high severity (CVSS 8.9), this vuln
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function formSetMacFilterCfg. Rated high severity (CVSS 7.5
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via function via set_device_name. Rated high severity (CVSS 7.5
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetWifiGusetBasic. Rated high sev
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, form_fast_setting_wifi_set. Rated high severit
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, setSchedWifi. Rated high severity (CVSS 7.5),
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, saveParentControlInfo. Rated high severity (CV
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: setSmartPowerManagement. Rated high
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, formSetDeviceName. Rated high severity (CVSS 7
Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via bin/httpd, function: formSetFirewallCfg. Rated high severi
]Tenda AC21 V 16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: fromSetSysTime. Rated high severity
Tenda AC21 V16.03.08.15 is vulnerable to Buffer Overflow via /bin/httpd, function: formSetQosBand. Rated high severity (
Same weakness CWE-119 – Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today