Skip to main content

Ac8 Firmware CVE-2025-12618

HIGH
Buffer Overflow (CWE-119)
2025-11-03 cna@vuldb.com
7.4
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
7.4 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:20 vuln.today
CVE Published
Nov 03, 2025 - 07:15 nvd
HIGH 7.4

DescriptionCVE.org

A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

AnalysisAI

A vulnerability has been found in Tenda AC8 16.03.34.06. Rated high severity (CVSS 7.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. A vulnerability has been found in Tenda AC8 16.03.34.06. This impacts an unknown function of the file /goform/DatabaseIniSet. The manipulation of the argument Time leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Affected products include: Tenda Ac8 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.

CVE-2025-51087 HIGH POC
8.6 Jul 24

Stack-based buffer overflow in the Tenda AC8V4 router (firmware V16.03.34.06) lets remote attackers corrupt memory by su

CVE-2023-48194 CRITICAL POC
9.8 Jul 09

Vulnerability in Tenda AC8v4 .V16.03.34.09 due to sscanf and the last digit of s8 being overwritten with \x0. Rated crit

CVE-2025-25668 CRITICAL POC
9.8 Feb 20

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 funct

CVE-2025-25667 CRITICAL POC
9.8 Feb 20

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentCon

CVE-2025-25664 CRITICAL POC
9.8 Feb 20

Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 funct

CVE-2025-25663 CRITICAL POC
9.8 Feb 20

A vulnerability was found in Tenda AC8V4 V16.03.34.06. Rated critical severity (CVSS 9.8), this vulnerability is remotel

CVE-2024-46652 CRITICAL POC
9.8 Sep 20

Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. Rated critical severity

CVE-2023-4744 CRITICAL POC
9.8 Sep 04

A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. Rated critical severity (CVSS 9.8), this vulnerability is r

CVE-2023-40900 CRITICAL POC
9.8 Aug 24

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter list at /goform/SetNe

CVE-2023-40899 CRITICAL POC
9.8 Aug 24

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter macFilterType and par

CVE-2023-40898 CRITICAL POC
9.8 Aug 24

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter timeZone at /goform/S

CVE-2023-40897 CRITICAL POC
9.8 Aug 24

Tenda AC8 v4 US_AC8V4.0si_V16.03.34.06_cn was discovered to contain a stack overflow via parameter mac at /goform/GetPar

Share

CVE-2025-12618 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy