Skip to main content

Centreon CVE-2025-12519

MEDIUM
Missing Authorization (CWE-862)
2026-01-05 bd4443e6-1eef-43f3-9886-25fc9ceeaae7
5.3
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Authorization checks on every request
MITRE ATT&CK

1 technique across 1 tactic: Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 5.3 (MEDIUM). Attack vector: Network. Complexity: Low. Privileges required: None. User interaction: None. Exploitation requires authentication.

Exploit ScenarioDerived

An attacker (requires authentication) could exploit this flaw, Information Disclosure like downtime or acknowledgement conf.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
Patch available 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations. [CVSS 5.3 MEDIUM]

RemediationAI

A vendor patch is available — apply it immediately. Restrict network access to the affected service where possible.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

Classified as CWE-862 (Missing Authorization). Affects Centreon Web. Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

Know when Centreon gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 5.3 MEDIUM
AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

2
Patch released
Jan 26, 2026 - 15:08 nvd
Patch available
CVE Published
Jan 05, 2026 - 11:17 nvd
MEDIUM 5.3

DescriptionCVE.org

Missing Authorization vulnerability in Centreon Infra Monitoring (Administration parameters API endpoint modules) allows Accessing Functionality Not Properly Constrained by ACLs, resulting in Information Disclosure like downtime or acknowledgement configurations. This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

Executive ViewAI

Why It Matters

CVE-2025-12519 presents moderate security risk, a missing authorization vulnerability rated CVSS 5.3. Attackers could gain access beyond their authorized level. A patch is available and should be applied during regular vulnerability management.

Business Impact: Low
Compensating Controls

Apply vendor patch. If patching is delayed: restrict network access and enable monitoring.

Threat Intelligence Overview

EPSS Score
0.0%
Top 99% exploitable
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.0%
Patch available Yes
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Low

Priority Score

26
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +26
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)CVE.org

cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*
cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*
cpe:2.3:a:centreon:centreon_web:*:*:*:*:*:*:*:*
CVE-2014-3829 CRITICAL POC
10.0 Oct 23

displayServiceStatus.php in Centreon 2.5.1 and Centreon Enterprise Server 2.2 (fixed in Centreon web 2.5.3) allows remot

CVE-2014-3828 CRITICAL POC
10.0 Oct 23

Multiple SQL injection vulnerabilities in Centreon 2.5.1 and Centreon Enterprise Server 2.2 (fixed in Centreon web 2.5.3

CVE-2025-5946 HIGH POC
7.2 Oct 14

Authenticated OS command injection in Centreon Web (Infra Monitoring) lets a high-privilege user execute arbitrary opera

CVE-2021-37558 CRITICAL POC
9.8 Aug 03

A SQL injection vulnerability in a MediaWiki script in Centreon before 20.04.14, 20.10.8, and 21.04.2 allows remote unau

CVE-2022-40043 HIGH POC
8.8 Sep 26

Centreon v20.10.18 was discovered to contain a SQL injection vulnerability via the esc_name (Escalation Name) parameter

CVE-2021-37557 HIGH POC
8.8 Aug 03

A SQL injection vulnerability in image generation in Centreon before 20.04.14, 20.10.8, and 21.04.2 allows remote authen

CVE-2021-37556 HIGH POC
8.8 Aug 03

A SQL injection vulnerability in reporting export in Centreon before 20.04.14, 20.10.8, and 21.04.2 allows remote authen

CVE-2020-13252 HIGH POC
8.8 May 21

Centreon before 19.04.15 allows remote attackers to execute arbitrary OS commands by placing shell metacharacters in RRD

CVE-2020-9463 HIGH POC
8.8 Feb 28

Centreon 19.10 allows remote authenticated users to execute arbitrary OS commands via shell metacharacters in the server

CVE-2019-17501 HIGH POC
8.8 Oct 14

Centreon 19.04 allows attackers to execute arbitrary OS commands via the Command Line field of main.php?p=60807&type=4 (

CVE-2019-17107 HIGH POC
8.8 Oct 08

minPlayCommand.php in Centreon Web before 2.8.27 allows authenticated attackers to execute arbitrary code via the comman

CVE-2019-13024 HIGH POC
8.8 Jul 01

Centreon 18.x before 18.10.6, 19.x before 19.04.3, and Centreon web before 2.8.29 allows the attacker to execute arbitra

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy