ABB Terra AC
CVE-2025-12142
MEDIUM
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain adjacent-network foothold near wallbox
-
DeliveryAuthenticate with high privileges
-
ExploitSend oversized input to vulnerable parser
-
ExecutionOverflow fixed-size buffer
-
ImpactCorrupt memory to disrupt or tamper with device
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Buffer copy size validation
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires two concurrent conditions reflected in the CVSS vector: (1) adjacent-network access (AV:A) - the attacker must be on the same local/management network or within wireless range of the Terra AC wallbox, not reachable from the open internet; and (2) high privileges (PR:H) - the attacker must already be authenticated with elevated rights on the device. No user interaction is needed (UI:N) and attack complexity is low (AC:L). These requirements affect Terra AC wallbox firmware through version 1.8.33. The dual requirement of local adjacency plus pre-existing privileged access is the primary limiting factor that substantially narrows realistic exploitation to insiders or attackers who have already compromised the local network and device credentials. |
| Impact | This is a medium-severity issue (vendor CVSS 4.0 base 6.9) whose signals are internally consistent and point to a constrained, non-urgent risk. The CVSS 4.0 vector (AV:A/AC:L/AT:N/PR:H/UI:N) shows exploitation requires adjacent-network access AND pre-existing high privileges, with no confidentiality impact (VC:N) but high integrity and availability impact (VI:H/VA:H) - i.e., an already-privileged local attacker could crash or tamper with the wallbox rather than steal data. EPSS is low at 0.21% (10th percentile), there is no CISA KEV listing and no public exploit identified, all of which align with the restrictive attack prerequisites to indicate this is not a widespread or opportunistic threat. No signals conflict: the low EPSS, absence of KEV, and high-privilege/adjacent-vector requirement all reinforce low real-world exploitation likelihood. The vulnerability was self-reported by ABB's own security team rather than discovered through observed attacks, further supporting that this is a proactively disclosed, not actively exploited, flaw. |
| Exploit ScenarioDerived | An attacker who already holds high-privilege access to an ABB Terra AC wallbox and is positioned on the adjacent network (e.g., the local management network or wireless range of the device) sends an oversized input that overflows a fixed-size buffer. This corrupts device memory, enabling the attacker to crash the charger or manipulate its operation (integrity/availability impact), though not to read confidential data. No public proof-of-concept exploit is available. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
ABB Terra AC wallbox firmware through version 1.8.33 contains a classic buffer overflow (CWE-120) that allows an attacker on the adjacent network with high privileges to corrupt memory, leading to high integrity and availability impact. Exploitation requires the attacker to already be authenticated with elevated rights and to be on the same local network or within wireless range; no public exploit code is identified at time of analysis and EPSS is low (0.21%, 10th percentile). The issue is not confirmed as actively exploited (no CISA KEV entry).
RemediationAI
ABB has published a security advisory (9AKK108471A8107) that should be consulted for patch availability and fixed firmware versions. Upgrade to a firmware version later than 1.8.33 once released. Until patching is possible, restrict access to the wallbox's management interfaces to trusted adjacent networks only, and ensure that only highly privileged, authenticated users can interact with the device. Enforce strong authentication and least privilege to mitigate the high-privileges requirement. Monitoring for unexpected device crashes or configuration changes can help detect exploitation attempts. Note that network segmentation may limit remote management capabilities. No public exploit code is identified, and the low EPSS score (0.21%) suggests limited exploitation activity.
Affected ProductsAI
ABB Terra AC wallbox firmware versions through 1.8.33 are affected. The vulnerability is documented in ABB advisory 9AKK108471A8107. No specific CPE strings were provided in the input data, but the affected product is the ABB Terra AC wallbox, an AC electric vehicle charger. The vulnerable component is the device firmware, and the issue is present in all versions up to and including 1.8.33.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The vulnerability is a classic buffer overflow (CWE-120) in the firmware of the ABB Terra AC wallbox, an AC electric vehicle charging station. The issue arises when the firmware copies input data into a fixed-size buffer without validating the length, potentially allowing an attacker to overwrite adjacent memory. The CVSS vector indicates the attack is launched from an adjacent network (AV:A) and requires high privileges (PR:H), meaning the attacker must already have authenticated access with elevated rights and be on the same local network or within wireless range. The impact is limited to integrity and availability (no confidentiality impact), suggesting the overflow may corrupt configuration or crash the device rather than leak sensitive data. The affected product is Terra AC wallbox firmware through version 1.8.33, as referenced in ABB advisory 9AKK108471A8107.
Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L
Adjacent vector and high-privilege requirement match the vendor data (AV:A, PR:H); buffer overflow yields integrity and availability impact (I:H/A:H) but no data disclosure (C:N).
Primary rating from Vendor (ch).
CVSS VectorVendor: ch
DescriptionCVE.org
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v3.08.01; NEXUS Series v3.08.01 ; MATRIX Series v3.08.
Unauthorized file access in WEB Server in ABB ASPECT - Enterprise v3.08.01; NEXUS Series v3.08.01 ; MATRIX Series v3.08.
cgi-bin/write.cgi in Anti-Web through 3.8.7, as used on NetBiter / HMS, Ouman EH-net, Alliance System WS100 --> AWU 500,
The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI i
The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication a
The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Rated high
The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. Rated high
The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Rated high severity (
Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login t
The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilizat
Path traversal in ABB Mint Workbench I through version 5876 allows any local user to reach files outside the intended re
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB