Skip to main content

Ex3700 Firmware CVE-2024-35522

HIGH
Command Injection (CWE-77)
2024-10-11 cve@mitre.org
7.2
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.2 (HIGH). Attack characteristics: network attack vector, low complexity, high privileges required, no user interaction not required. Public proof-of-concept exploit code is available.

Exploit ScenarioDerived

A remote attacker could inject arbitrary commands into system command execution by sending crafted requests to the affected application.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 1.8% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone. Affected products include: Netgear Ex3700 Firmware. Version information: before 1.0.0.98.

Know when Ex3700 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.2 HIGH
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.

Threat Intelligence Overview

EPSS Score
1.8%
Top 24% exploitable
Exploit
POC
Public exploit code exists
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC Yes
EPSS 1.8%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

58
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +36
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

Affected Products (CPE)NVD

cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*
CVE-2025-5934 HIGH POC
8.8 Jun 10

A critical stack-based buffer overflow vulnerability (CVE-2025-5934) exists in Netgear EX3700 wireless extenders up to v

CVE-2021-45621 CRITICAL
9.8 Dec 26

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. Rated critical severity (CVSS

CVE-2021-45512 CRITICAL
9.8 Dec 26

Certain NETGEAR devices are affected by weak cryptography. Rated critical severity (CVSS 9.8), this vulnerability is rem

CVE-2020-35796 CRITICAL
9.8 Dec 30

Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. Rated critical severity (CVSS

CVE-2020-35800 CRITICAL
9.4 Dec 30

Certain NETGEAR devices are affected by incorrect configuration of security settings. Rated critical severity (CVSS 9.4)

CVE-2021-45641 HIGH
8.8 Dec 26

Certain NETGEAR devices are affected by incorrect configuration of security settings. Rated high severity (CVSS 8.8), th

CVE-2021-34991 HIGH
8.8 Nov 15

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R640

CVE-2021-32122 HIGH
8.0 Aug 11

Certain NETGEAR devices are affected by CSRF. Rated high severity (CVSS 8.0), this vulnerability is no authentication re

CVE-2021-45640 HIGH
7.2 Dec 26

Certain NETGEAR devices are affected by incorrect configuration of security settings. Rated high severity (CVSS 7.2), th

CVE-2024-35519 MEDIUM
6.8 Oct 14

Netgear EX6120 v1.0.0.68, Netgear EX6100 v1.0.2.28, and Netgear EX3700 v1.0.0.96 are vulnerable to command injection in

CVE-2021-45533 MEDIUM
6.8 Dec 26

Certain NETGEAR devices are affected by command injection by an authenticated user. Rated medium severity (CVSS 6.8), th

CVE-2021-45639 MEDIUM
6.1 Dec 26

Certain NETGEAR devices are affected by reflected XSS. Rated medium severity (CVSS 6.1), this vulnerability is remotely

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy