Ac18 Firmware
CVE-2024-30891
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 8.8 (HIGH). Attack characteristics: adjacent network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | An attacker could exploit this vulnerability to inject arbitrary commands into system command execution. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution. Affected products include: Tenda Ac18 Firmware.
Know when Ac18 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from Vendor (mitre) · only source for this CVE.
CVSS VectorVendor: mitre
DescriptionCVE.org
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
Affected Products (CPE)CVE.org
More in Ac18 Firmware
View allTenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload func
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Rated critical severity (CVSS 9.8), thi
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. Rated
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Rated critic
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Rat
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName paramet
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Rated critical severity (CVSS 9.8
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime fu
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Rated critical severity (CV
NVD
CVE.org
EPSS
GitHub
Exploit-DB