Totally Integrated Automation Portal CVE-2023-46284

HIGH
Classic Buffer Overflow (CWE-120)
2023-12-12 productcert@siemens.com
7.5
CVSS 3.1 · Vendor: siemens
Share

Severity by source

Vendor (siemens) PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from Vendor (siemens) · only source for this CVE.

CVSS VectorVendor: siemens

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

1
CVE Published
Dec 12, 2023 - 12:15 cve.org
HIGH 7.5

DescriptionCVE.org

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash.

AnalysisAI

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions <. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Buffer Copy without Size Check vulnerability could allow attackers to overflow a buffer to corrupt adjacent memory.

Technical ContextAI

This vulnerability is classified as Buffer Copy without Size Check (CWE-120), which allows attackers to overflow a buffer to corrupt adjacent memory. A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an out of bounds write past the end of an allocated buffer when handling specific requests on port 4002/tcp and 4004/tcp. This could allow an attacker to crash the application. The corresponding service is auto-restarted after the crash. Affected products include: Siemens Opcenter Quality, Siemens Simatic Pcs Neo, Siemens Sinumerik Integrate Runmyhmi \/Automotive, Siemens Totally Integrated Automation Portal.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Always validate buffer sizes before copy operations. Use bounded functions (strncpy, snprintf). Enable compiler protections.