Skip to main content

Opcenter Quality CVE-2023-46282

MEDIUM
Cross-site Scripting (XSS) (CWE-79)
2023-12-12 productcert@siemens.com
6.1
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
6.1 MEDIUM
AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Dec 12, 2023 - 12:15 nvd
MEDIUM 6.1

DescriptionNVD

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

AnalysisAI

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions <. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. This Cross-Site Scripting (XSS) vulnerability could allow attackers to inject malicious scripts into web pages viewed by other users.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. Affected products include: Siemens Opcenter Quality, Siemens Simatic Pcs Neo, Siemens Sinumerik Integrate Runmyhmi \/Automotive, Siemens Totally Integrated Automation Portal.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

CVE-2021-27389 CRITICAL
9.8 Apr 22

A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30).

CVE-2023-46281 HIGH
8.8 Dec 12

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versi

CVE-2020-7587 HIGH
8.2 Jul 14

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation

CVE-2023-46285 HIGH
7.5 Dec 12

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versi

CVE-2023-46284 HIGH
7.5 Dec 12

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versi

CVE-2023-46283 HIGH
7.5 Dec 12

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versi

CVE-2022-33736 HIGH
7.5 Jul 12

A vulnerability has been identified in Opcenter Quality V13.1 (All versions < V13.1.20220624), Opcenter Quality V13.2 (A

CVE-2020-7581 MEDIUM
6.7 Jul 14

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation

CVE-2020-7588 MEDIUM
5.3 Jul 14

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation

CVE-2024-41986 MEDIUM
6.1 Aug 12

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Au

CVE-2024-41985 LOW
2.1 Aug 12

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Au

CVE-2024-41984 LOW
2.1 Aug 12

A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Au

Share

CVE-2023-46282 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy